New 2-D dosimetric technique for radiotherapy based on planar thermoluminescent detectors

被引:31
作者
Olko, P.
Marczewska, B.
Czopyk, L.
Czermak, M. A.
Klosowski, M.
Waligorski, M. P. R.
机构
[1] PAN, Inst Nucl Phys, PL-31342 Krakow, Poland
[2] Ctr Oncol, PL-31115 Krakow, Poland
关键词
D O I
10.1093/rpd/ncl019
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
At the Institute of Nuclear Physics of the Polish Academy of Sciences (IFJ) in Krakow, a two-dimensional (2-D) thermo-luminescence (TL) dosimetry system was developed within the MAESTRO (Methods and Advanced Equipment for Simulation and Treatment in Radio-Oncology) 6 Framework Programme and tested by evaluating 2-D dose distributions around radioactive sources. A thermoluminescent detector (TLD) foil was developed, of thickness 0.3 into and diameter 60 mm, containing a mixture of highly sensitive LiF:Mg,Cu,P powder and Ethylene TetraFluoroEthylene (ETFE) polymer. Foil detectors were irradiated with Ra-266 brachytherapy sources and a Sr-90/Y-90 source. 2-D dose distributions were evaluated using a prototype planar (diameter 60 mm) reader, equipped with a 12 bit Charge Coupled Devices (CCD) PCO AG camera, with a. p resolution of 640 x 480 pixels. The new detectors, showing a spatial resolution better than 0.5 rum and a measurable dose range typical for radiotherapy, can find many applications in clinical dosimetry. Another technology applicable to clinical dosimetry, also developed at IFJ, is the Si microstrip detector of size 95 x 95 into, which may be used to evaluate the dose distribution with a spatial resolution of 120 pm along one direction, in real-time mode. The microstrip and TLD technology will be further improved, especially to develop detectors of larger area, and to make them applicable to some advanced radiotherapy modalities, such as intensity modulated radiotherapy (IMRT) or proton radiotherapy.
引用
收藏
页码:213 / 218
页数:6
相关论文
共 20 条
  • [1] Miniature thermoluminescent detectors for dosimetry in radiotherapy
    Bilski, P
    Waligórski, MPR
    Budzanowski, M
    Ochab, E
    Olko, P
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 473 - 476
  • [2] Spatial resolution of a stacked radiochromic film dosimeter
    Butson, MJ
    Cheung, T
    Yu, PKN
    [J]. RADIOTHERAPY AND ONCOLOGY, 2001, 61 (02) : 211 - 213
  • [3] Silicon Ultra fast Cameras for electron and γ sources In Medical Applications
    Caccia, M
    Airoldi, A
    Alemi, M
    Amati, M
    Badano, L
    Bartsch, V
    Berst, D
    Bianchi, C
    Bol, H
    Bulgheroni, A
    Cannillo, F
    Cappellini, C
    Czermak, A
    Claus, G
    Colledani, C
    Conte, L
    Deptuch, G
    de Boer, W
    Dierlamm, A
    Domanski, K
    Dulinski, W
    Dulny, B
    Ferrando, O
    Grigoriev, E
    Grabiec, P
    Lorusso, R
    Jaroszewicz, B
    Jungermann, L
    Kucewicz, W
    Kucharski, K
    Kuta, S
    Leo, G
    Machowski, W
    Marczewski, J
    Mondry, G
    Niemiec, H
    Novario, R
    Paolucci, L
    Pezzetta, M
    Popowski, Y
    Riester, JL
    Sampietro, C
    Sapor, M
    Schweickert, H
    Spanò, B
    Tomaszewski, D
    Zalewska, A
    [J]. NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 2003, 125 : 133 - 138
  • [4] The use of GAFchromic film to determine the absolute activity of beta emitters
    Fox, RA
    Barker, P
    Smart, G
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (04) : 833 - 842
  • [5] LASER-HEATING IN THERMO-LUMINESCENCE DOSIMETRY
    GASIOT, J
    BRAUNLICH, P
    FILLARD, JP
    [J]. JOURNAL OF APPLIED PHYSICS, 1982, 53 (07) : 5200 - 5209
  • [6] SPATIAL-DISTRIBUTION READOUT SYSTEM OF THERMO-LUMINESCENCE SHEETS
    IMAEDA, K
    KITAJIMA, T
    KUGA, K
    MIONO, S
    MISAKI, A
    NAKAMURA, M
    NINAGAWA, K
    OKAMOTO, Y
    SAAVEDRA, O
    SAITO, T
    TAKAHASHI, N
    TAKANO, Y
    TOMIYAMA, T
    WADA, T
    YAMAMOTO, I
    YAMASHITA, Y
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 241 (2-3) : 567 - 571
  • [7] INVIVO MEASUREMENT OF SPATIAL DOSE DISTRIBUTION WITH THERMOLUMINESCENT SHEET AROUND HIGH DOSE-RATE INTRACAVITARY SOURCE - APPLICATION TO RECTAL-CANCER
    IWATA, K
    YOSHIMURA, H
    TSUJI, Y
    SHIRAI, A
    UTO, F
    TAMADA, T
    YAMAMOTO, I
    TOMIYAMA, T
    WADA, T
    OHISHI, H
    UCHIDA, H
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 22 (05): : 1109 - 1115
  • [8] IAEA/WHO TLD postal dose audit service and high precision measurements for radiotherapy level dosimetry
    Izewska, J
    Bera, P
    Vatnitsky, S
    [J]. RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 387 - 392
  • [9] JONES SC, 1993, RADIAT PROT DOSIM, V47, P457
  • [10] Patient and personnel dosimetry in endovascular radiotherapy with 90Sr/90Y sources
    Kalef-Ezra, J
    Bozios, G
    Tsekeris, P
    Michalis, L
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (04) : 514 - 523