Fast Robust Dejitter and Interslice Discontinuity Removal in MRI Phase Acquisitions: Application to Magnetic Resonance Elastography

被引:19
作者
Barnhill, Eric [1 ]
Nikolova, Mila [2 ]
Ariyurek, Cemre [3 ]
Dittmann, Florian [4 ]
Braun, Juergen [5 ]
Sack, Ingolf [4 ]
机构
[1] iRhythm Technol, San Francisco, CA 94103 USA
[2] Univ Paris Saclay, ENS Cachan, CMLA, CNRS, F-94235 Cachan, France
[3] Bilkent Univ, Natl Magnet Resonance Res Ctr UMRAM, TR-06800 Ankara, Turkey
[4] Charite Univ Med Berlin, Dept Radiol, D-10117 Berlin, Germany
[5] Charite Univ Med Berlin, Inst Med Informat, D-10117 Berlin, Germany
基金
欧盟地平线“2020”;
关键词
Magnetic resonance imaging; elastography; image denoising; INVERSION; VISCOELASTICITY; RESOLUTION; MOTION; HEAD;
D O I
10.1109/TMI.2019.2893369
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
MRI phase contrast imaging methods that assemble slice-wise acquisitions into volumes can contain interslice phase discontinuities (IPDs) over the course of the scan from sources, including unavoidable physiological activity. In magnetic resonance elastography (MRE), this can alter wavelength and tissue stiffness estimates, invalidating the analysis. We first model this behavior as jitter along the z-axis of the phase of 3D complex-valued wave volumes. A two-step image processing pipeline is then proposed that removes IPDs. First, constant slicewise phase shift is removed with a novel, non-convex dejittering algorithm. Then, regional physiological noise artifacts are removed with novel filtering of 3D wavelet coefficients. Calibration of two pipeline coefficients, the dejitter parameter alpha and the wavelet band high-pass coefficient omega(c), was first performed on a finite-element method brain phantom. A comparative investigation was then performed, on a cohort of 48 brain acquisitions, of four approaches to IPDs: 1) the proposed method; 2) a "control" condition of neglect of IPDs; 3) an anisotropic wavelet-based method; and 4) a method of in-plane (2D) processing. The present-method showed medians of vertical bar G*vertical bar = 1873 Pa for a multifrequency wave inversion centered at 40 Hz which was within 6% of methods 3) and 4), while neglect produced vertical bar G*vertical bar estimates a mean of 17% lower. The proposed method reduced the value range of the cohort against methods 3) and 4) by 29% and 31%, respectively. Such reduction in variance enhances the ability of brain MRE to predict subtler physiological changes. Our theoretical approach further enables more powerful applications of fundamental findings in noise and denoising to MRE.
引用
收藏
页码:1578 / 1587
页数:10
相关论文
共 39 条
[1]  
[Anonymous], WAVELET TOUR SIGNAL
[2]   A new improved version of the realistic digital brain phantom [J].
Aubert-Broche, Berengere ;
Evans, Alan C. ;
Collins, Louis .
NEUROIMAGE, 2006, 32 (01) :138-145
[3]   Heterogeneous Multifrequency Direct Inversion (HMDI) for magnetic resonance elastography with application to a clinical brain exam [J].
Barnhill, Eric ;
Davies, Penny J. ;
Ariyurek, Cemre ;
Fehlner, Andreas ;
Braun, Juergen ;
Sack, Ingolf .
MEDICAL IMAGE ANALYSIS, 2018, 46 :180-188
[4]   Nonlinear multiscale regularisation in MR elastography: Towards fine feature mapping [J].
Barnhill, Eric ;
Hollis, Lyam ;
Sack, IngoIf ;
Braun, Juergen ;
Hoskins, Peter R. ;
Pankaj, Pankaj ;
Brown, Colin ;
van Beek, Edwin J. R. ;
Roberts, Neil .
MEDICAL IMAGE ANALYSIS, 2017, 35 :133-145
[5]   Two-dimensional MR elastrography with linear inversion reconstruction: methodology and noise analysis [J].
Bishop, J ;
Samani, A ;
Sciarretta, J ;
Plewes, DB .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (08) :2081-2091
[6]   In Vivo Wideband Multifrequency MR Elastography of the Human Brain and Liver [J].
Dittmann, Florian ;
Hirsch, Sebastian ;
Tzschaetzsch, Heiko ;
Guo, Jing ;
Braun, Juergen ;
Sack, Ingolf .
MAGNETIC RESONANCE IN MEDICINE, 2016, 76 (04) :1116-1126
[7]  
DONOHO DL, 1995, J ROY STAT SOC B MET, V57, P301
[8]   Increasing the spatial resolution and sensitivity of magnetic resonance elastography by correcting for subject motion and susceptibility-induced image distortions [J].
Fehlner, Andreas ;
Hirsch, Sebastian ;
Weygandt, Martin ;
Christophel, Thomas ;
Barnhill, Eric ;
Kadobianskyi, Mykola ;
Braun, Juergen ;
Bernarding, Johannes ;
Luetzkendorf, Ralf ;
Sack, Ingolf ;
Hetzer, Stefan .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2017, 46 (01) :134-141
[9]   Higher-Resolution MR Elastography Reveals Early Mechanical Signatures of Neuroinflammation in Patients with Clinically Isolated Syndrome [J].
Fehlner, Andreas ;
Behrens, Janina Ruth ;
Streitberger, Kaspar-Josche ;
Papazoglou, Sebastian ;
Braun, Juergen ;
Bellmann-Strobl, Judith ;
Ruprecht, Klemens ;
Paul, Friedemann ;
Wuerfel, Jens ;
Sack, Ingolf .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (01) :51-58
[10]   PULSATILE BRAIN MOVEMENT AND ASSOCIATED HYDRODYNAMICS STUDIED BY MAGNETIC-RESONANCE PHASE IMAGING - THE MONRO-KELLIE DOCTRINE REVISITED [J].
GREITZ, D ;
WIRESTAM, R ;
FRANCK, A ;
NORDELL, B ;
THOMSEN, C ;
STAHLBERG, F .
NEURORADIOLOGY, 1992, 34 (05) :370-380