Influence of different electrode belt positions on electrical impedance tomography imaging of regional ventilation: a prospective observational study

被引:81
作者
Karsten, Jan [1 ]
Stueber, Thomas [1 ]
Voigt, Nicolas [1 ]
Teschner, Eckhard [2 ]
Heinze, Hermann [3 ]
机构
[1] Hannover Med Sch, Dept Anaesthesiol & Intens Care Med, D-30625 Hannover, Germany
[2] Draeger Med GmbH, D-23558 Lubeck, Germany
[3] Med Univ Lubeck, Dept Anaesthesiol & Intens Care Med, D-23538 Lubeck, Germany
来源
CRITICAL CARE | 2016年 / 20卷
关键词
RESPIRATORY-DISTRESS-SYNDROME; TIDAL-VOLUME VENTILATION; MECHANICAL VENTILATION; ABDOMINAL-SURGERY; LUNG INJURY; BEDSIDE; PEEP; EIT; ANESTHESIA; PRESSURE;
D O I
10.1186/s13054-015-1161-9
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Electrical impedance tomography (EIT) is a non-invasive bedside tool which allows an individualized ventilator strategy by monitoring tidal ventilation and lung aeration. EIT can be performed at different cranio-caudal thoracic levels, but data are missing about the optimal belt position. The main goal of this prospective observational study was to evaluate the impact of different electrode layers on tidal impedance variation in relation to global volume changes in order to propose a proper belt position for EIT measurements. Methods: EIT measurements were performed in 15 mechanically ventilated intensive care patients with the electrode belt at different thoracic layers (L1-L7). All respiratory and hemodynamic parameters were recorded. Blood gas analyses were obtained once at the beginning of EIT examination. Off-line tidal impedance variation/tidal volume (TV/VT) ratio was calculated, and specific patterns of impedance distribution due to automatic and user-defined adjustment of the colour scale for EIT images were identified. Results: TV/VT ratio is the highest at L1. It decreases in caudal direction. At L5, the decrease of TV/VT ratio is significant. We could identify patterns of diaphragmatic interference with ventilation-related impedance changes, which owing to the automatically adjusted colour scales are not obvious in the regularly displayed EIT images. Conclusions: The clinical usability and plausibility of EIT measurements depend on proper belt position, proper impedance visualisation, correct analysis and data interpretation. When EIT is used to estimate global parameters like VT or changes in end-expiratory lung volume, the best electrode plane is between the 4th and 5th intercostal space. The specific colour coding occasionally suppresses user-relevant information, and manual rescaling of images is necessary to visualise this information.
引用
收藏
页数:10
相关论文
共 25 条
[1]   Whither lung EIT: Where are we, where do we want to go and what do we need to get there? [J].
Adler, Andy ;
Amato, Marcelo B. ;
Arnold, John H. ;
Bayford, Richard ;
Bodenstein, Marc ;
Boehm, Stephan H. ;
Brown, Brian H. ;
Frerichs, Inez ;
Stenqvist, Ola ;
Weiler, Norbert ;
Wolf, Gerhard K. .
PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) :679-694
[2]   The Role of Potentially Preventable Hospital Exposures in the Development of Acute Respiratory Distress Syndrome: A Population-Based Study [J].
Ahmed, Adil H. ;
Litell, John M. ;
Malinchoc, Michael ;
Kashyap, Rahul ;
Schiller, Henry J. ;
Pannu, Sonal R. ;
Singh, Balwinder ;
Li, Guangxi ;
Gajic, Ognjen .
CRITICAL CARE MEDICINE, 2014, 42 (01) :31-39
[3]   Electrical impedance tomography measured at two thoracic levels can visualize the ventilation distribution changes at the bedside during a decremental positive end-expiratory lung pressure trial [J].
Bikker, Ido G. ;
Preis, Carsten ;
Egal, Mahamud ;
Bakker, Jan ;
Gommers, Diederik .
CRITICAL CARE, 2011, 15 (04)
[4]   Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels [J].
Bikker, Ido G. ;
Leonhardt, Steffen ;
Bakker, Jan ;
Gommers, Diederik .
INTENSIVE CARE MEDICINE, 2009, 35 (08) :1362-1367
[5]   Lung monitoring at the bedside in mechanically ventilated patients [J].
Blankman, Paul ;
Gommers, Diederik .
CURRENT OPINION IN CRITICAL CARE, 2012, 18 (03) :261-266
[6]  
Draeger Medical GmbH, 2011, TECHN DOC IPM PULMOV
[7]   Electrical impedance tomography imaging of the cardiopulmonary system [J].
Frerichs, Inez ;
Becher, Tobias ;
Weiler, Norbert .
CURRENT OPINION IN CRITICAL CARE, 2014, 20 (03) :323-332
[8]   EFFECTS OF ANESTHESIA AND PARALYSIS ON DIAPHRAGMATIC MECHANICS IN MAN [J].
FROESE, AB ;
BRYAN, AC .
ANESTHESIOLOGY, 1974, 41 (03) :242-255
[9]   A Trial of Intraoperative Low-Tidal-Volume Ventilation in Abdominal Surgery [J].
Futier, Emmanuel ;
Constantin, Jean-Michel ;
Paugam-Burtz, Catherine ;
Pascal, Julien ;
Eurin, Mathilde ;
Neuschwander, Arthur ;
Marret, Emmanuel ;
Beaussier, Marc ;
Gutton, Christophe ;
Lefrant, Jean-Yves ;
Allaouchiche, Bernard ;
Verzilli, Daniel ;
Leone, Marc ;
De Jong, Audrey ;
Bazin, Jean-Etienne ;
Pereira, Bruno ;
Jaber, Samir .
NEW ENGLAND JOURNAL OF MEDICINE, 2013, 369 (05) :428-437
[10]   End-expiratory lung impedance change enables bedside monitoring of end-expiratory lung volume change [J].
Hinz, J ;
Hahn, G ;
Neumann, P ;
Sydow, M ;
Mohrenweiser, P ;
Hellige, G ;
Burchardi, H .
INTENSIVE CARE MEDICINE, 2003, 29 (01) :37-43