Entropy and bispectral index during anaesthesia in children

被引:26
作者
Davidson, AJ [1 ]
Kim, MJ [1 ]
Sangolt, GK [1 ]
机构
[1] Royal Childrens Hosp, Dept Anaesthesia & Pain Management, Melbourne, Vic, Australia
关键词
anaesthetic monitoring : bispectral index; entropy; paediatric;
D O I
10.1177/0310057X0403200405
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Entropy'm is a new EEG based technology developed as a measure of depth of anaesthesia. The Entropy algorithm quantifies the degree of disorder in the EEG. During anaesthesia the disorder of the EEG, or entropy, falls. Entropy is independent of absolute frequency or amplitude of the EEG. This may make it suitable for paediatric anaesthesia. In this prospective observational blinded study we recorded the Entropy and Bispectral Index(TM) in 23 children undergoing general anaesthesia with isoflurane and nitrous oxide, supplemented with peripheral nerve blockade. We recorded Entropy at several times during anaesthesia, pre-awakening and 1-minute post-awakening. Entropy pre-awakening and 1 minute after awakening was compared to a value during anaesthesia in three age groups; less than one-year-old (infants), one to five years (toddlers) and five to twelve years (children). The correlation between BIS and Entropy was also calculated. Entropy post-awakening was higher than during anaesthesia for all age groups. Entropy pre-awakening was higher than during anaesthesia for the children and toddlers. This was not as apparent in infants. There was a strong correlation between BIS and Entropy for children and toddlers. The correlation was less for infants. This study demonstrates that, in children, Entropy is lower during anaesthesia when compared to awake values. Further evaluation in the paediatric population is worthwhile.
引用
收藏
页码:485 / 493
页数:9
相关论文
共 13 条
[1]  
Bannister CF, 2001, ANESTH ANALG, V92, P877
[2]   Correlation of approximate entropy, bispectral index, and spectral edge frequency 95 (SEF95) with clinical signs of "anesthetic depth" during coadministration of propofol and remifentanil [J].
Bruhn, J ;
Bouillon, TW ;
Radulescu, L ;
Hoeft, A ;
Bertaccini, E ;
Shafer, SL .
ANESTHESIOLOGY, 2003, 98 (03) :621-627
[3]   Artifact robustness, inter- and intraindividual baseline stability, and rational EEG parameter selection [J].
Bruhn, J ;
Bouillon, TW ;
Hoeft, A ;
Shafer, SL .
ANESTHESIOLOGY, 2002, 96 (01) :54-59
[4]   Onset of propofol-induced burst suppression may be correctly detected as deepening of anaesthesia by approximate entropy but not by bispectral index [J].
Bruhn, J ;
Bouillon, TW ;
Shafer, SL .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 87 (03) :505-507
[5]   Electroencephalogram approximate entropy correctly classifies the occurrence of burst suppression pattern as increasing anesthetic drug effect [J].
Bruhn, J ;
Röpcke, H ;
Rehberg, B ;
Bouillon, T ;
Hoeft, A .
ANESTHESIOLOGY, 2000, 93 (04) :981-985
[6]   Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia [J].
Bruhn, J ;
Röpcke, H ;
Hoeft, A .
ANESTHESIOLOGY, 2000, 92 (03) :715-726
[7]   The differences in the bispectral index between infants and children during emergence from anesthesia after circumcision surgery [J].
Davidson, AJ ;
McCann, ME ;
Devavaram, P ;
Auble, SA ;
Sullivan, LJ ;
Gillis, JM ;
Laussen, PC .
ANESTHESIA AND ANALGESIA, 2001, 93 (02) :326-330
[8]   EEG bispectral index and hypnotic component of anaesthesia induced by sevoflurane: comparison between children and adults [J].
Degoute, CS ;
Macabeo, C ;
Dubreuil, C ;
Duclaux, R ;
Banssillon, V .
BRITISH JOURNAL OF ANAESTHESIA, 2001, 86 (02) :209-212
[9]   Pediatric evaluation of the bispectral index (BIS) monitor and correlation of BIS with end-tidal sevoflurane concentration in infants and children [J].
Denman, WT ;
Swanson, EL ;
Rosow, D ;
Ezbicki, K ;
Connors, PD ;
Rosow, CE .
ANESTHESIA AND ANALGESIA, 2000, 90 (04) :872-877
[10]  
Lopes da Silva FHLD, 1999, ELECTROENCEPHALOGRAP