27-gauge trocar-assisted sutureless intraocular lens fixation

被引:15
作者
Jujo, Tatsuya [1 ]
Kogo, Jiro [1 ]
Sasaki, Hiroki [1 ]
Sekine, Reio [1 ]
Sato, Keiji [1 ]
Ebisutani, Sakura [1 ]
Toyoda, Yasuhiro [1 ]
Kitaoka, Yasushi [1 ]
Takagi, Hitoshi [1 ]
机构
[1] St Marianna Univ, Dept Ophthalmol, Sch Med, Miyamae Ku, 2-16-1 Sugao, Kawasaki, Kanagawa, Japan
关键词
Sutureless intraocular lens fixation; 27-gauge trocar; Flange technique; 27G vitrectomy; CASIA2;
D O I
10.1186/s12886-020-01758-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundsHowever there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar.MethodsNineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o'clock, 2mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications.ResultsThe 19 eyes were followed up for 1month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.060.63 and 0.40 +/- 0.26, respectively (p<0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27<plus/minus>0.51 and 0.06 +/- 0.15, respectively (p=0.09). The mean corneal endothelial cell density was 2406 +/- 625 to 2004 +/- 759 cells/mm(2) at 1month (p=0.13). The mean IOL tilt was 3.52 +/- 3.00 degrees, and the mean IOL decentration was 0.39 +/- 0.39mm. There was no correlation among IOL tilt, decentration and BCVA (p>0.05). The mean prediction error of the target refraction was -0.03 +/- 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred.Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.
引用
收藏
页数:8
相关论文
共 26 条
  • [1] Handshake technique for glued intrascleral haptic fixation of a posterior chamber intraocular lens
    Agarwal, Amar
    Jacob, Soosan
    Kumar, Dhivya Ashok
    Agarwal, Ashvin
    Narasimhan, Smita
    Agarwal, Athiya
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (03) : 317 - 322
  • [2] Transsderal fixation of a foldable intraocular lens in aphakic vitrectomized eyes
    Ahn, JK
    Yu, HG
    Chung, H
    Wee, WR
    Lee, JH
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (12) : 2390 - 2396
  • [3] Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: Clinical results
    Chan, CC
    Crandall, AS
    Ahmed, IIK
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (01) : 121 - 128
  • [4] 27-gauge trocar-assisted transconjunctival sutureless intraocular lens scleral fixation
    Diamint, David Vladimir
    Giambruni, Juan Martin
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (03) : NP65 - NP69
  • [5] Fernández-Buenaga R, 2013, EYE, V27, P795, DOI 10.1038/eye.2013.95
  • [6] Sutureless intrascleral posterior chamber intraocular lens fixation
    Gabor, Scharioth G. B.
    Pavlidis, Mitrofanis M.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (11) : 1851 - 1854
  • [7] Late in-the-bag intraocular lens dislocation: Incidence, prevention, and management
    Gimbel, HV
    Condon, GP
    Kohnen, T
    Olson, RJ
    Halkiadakis, I
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (11) : 2193 - 2204
  • [8] GUYTON DL, 1990, OPHTHALMOLOGY, V97, P1259
  • [9] Correlation between pupillary size and intraocular lens decentration and visual acuity of a zonal-progressive multifocal lens and a monofocal lens
    Hayashi, K
    Hayashi, H
    Nakao, F
    Hayashi, F
    [J]. OPHTHALMOLOGY, 2001, 108 (11) : 2011 - 2017
  • [10] Sutureless 27-gauge needle-assisted transconjunctival intrascleral intraocular lens fixation: Initial experience
    Kelkar, Aditya Shrikant
    Fogla, Rajesh
    Kelkar, Jai
    Kothari, Akshay Anil
    Mehta, Hetal
    Amoaku, Winfried
    [J]. INDIAN JOURNAL OF OPHTHALMOLOGY, 2017, 65 (12) : 1450 - 1453