ACCURACY AND PRECISION OF A PLANE WAVE VECTOR FLOW IMAGING METHOD IN THE HEALTHY CAROTID ARTERY

被引:13
作者
Jensen, Jonas [1 ]
Hoyos, Carlos Armando Villagomez [1 ]
Traberg, Marie Sand [1 ]
Olesen, Jacob Bjerring [1 ]
Tomov, Borislav Gueorguiev [1 ]
Moshavegh, Ramin [1 ]
Holbek, Simon [1 ]
Stuart, Matthias Bo [1 ]
Ewertsen, Caroline [2 ]
Hansen, Kristoffer Lindskov [2 ]
Thomsen, Carsten [2 ]
Nielsen, Michael Bachmann [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, Lyngby, Denmark
[2] Copenhagen Univ Hosp, Dept Radiol, Copenhagen, Denmark
关键词
Blood velocity estimation; Vector flow imaging; Plane wave imaging; Complex flow; Carotid artery; BLOOD-FLOW; VELOCITY ESTIMATION; TRANSVERSE OSCILLATION; DOPPLER ULTRASOUND; PEAK VELOCITY; ANGLE; QUANTIFICATION; VELOCIMETRY; SIMULATIONS; DYNAMICS;
D O I
10.1016/j.ultrasmedbio.2018.03.017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (WI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance angiography (MRA); (iii) the precision of VFI estimation in vivo at several evaluation points in the vessels. The carotid artery at the bifurcation was scanned using both fast plane wave ultrasound and MRA in 10 healthy volunteers. The MRA geometry acquired from one of the volunteers was used to fabricate an anthropomorphic flow phantom, which was also scanned using the fast plane wave sequence. The same geometry was used in a CFD simulation to calculate the velocity field. Results indicated that similar How patterns and vortices were estimated with CFD and VFI in the phantom for the carotid bifurcation. The root-mean-square difference between CFD and VFI was within 0.12 m/s for velocity estimates in the common carotid artery and the internal branch. The root-mean-square difference was 0.17 m/s in the external branch. For the 10 volunteers, the mean difference between VFI and MRA was-0.17 m/s for peak systolic velocities of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD = 3.6% for velocity magnitudes and 4.5 degrees for angles) and lowest in the external branch and for vortices (SD = 10.2% for velocity magnitudes and 39 degrees for angles). The results indicate that plane wave VFI measures flow precisely and that estimates are in good agreement with a CFD simulation and MRA. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1727 / 1741
页数:15
相关论文
共 50 条
[41]   An Angle-Independent Cross-Sectional Doppler Method for Flow Estimation in the Common Carotid Artery [J].
van Knippenberg, Luuk ;
van Sloun, Ruud J. G. ;
Shulepov, Sergei ;
Bouwman, R. Arthur ;
Mischi, Massimo .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (08) :1513-1524
[42]   Two-dimensional Blood Flow Vector and Wall Shear Stress of Carotid Artery Obtained with Dual-angle Doppler Method [J].
Akagawa, Osamu ;
Fukazu, Kosuke ;
Nagaoka, Ryo ;
Saijo, Yoshifumi .
2016 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2016,
[43]   Flow and distension in the carotid artery from magnetic resonance imaging [J].
Yim, PJ ;
Demarco, JK .
MEDICAL IMAGING 2004: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2004, 5 (23) :524-528
[44]   PULSE WAVE IMAGING IN CAROTID ARTERY STENOSIS HUMAN PATIENTS IN VIVO [J].
Li, Ronny X. ;
Apostolakis, Iason Z. ;
Kemper, Paul ;
McGarry, Matthew D. J. ;
Ip, Ada ;
Connolly, Edward S. ;
McKinsey, James F. ;
Konofagou, Elisa E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (02) :353-366
[45]   Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging [J].
Barratt, DC ;
Davies, AH ;
Hughes, AD ;
Thom, SA ;
Humphries, KN .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2001, 27 (10) :1421-1425
[46]   Velocity vector comparison between vector flow imaging and computational fluid dynamics in the carotid bifurcation [J].
Poloni, Sofia ;
Bozzetto, Michela ;
Du, Yigang ;
Aiani, Luca ;
Goddi, Alfredo ;
Fiorina, Ilaria ;
Remuzzi, Andrea .
ULTRASONICS, 2023, 128
[47]   Triangulation Based Vector Flow Imaging with Non-steered Plane Waves for Transverse Flows [J].
Madhavanunni, A. N. ;
Panicker, Mahesh Raveendranatha .
MEDICAL IMAGING 2020: ULTRASONIC IMAGING AND TOMOGRAPHY, 2020, 11319
[48]   Hemodynamical behavior analysis of anemic, diabetic, and healthy blood flow in the carotid artery [J].
Ahmed, Hashnayne ;
Podder, Chinmayee .
HELIYON, 2024, 10 (04)
[49]   4D Flow MR Imaging of Ophthalmic Artery Flow in Patients with Internal Carotid Artery Stenosis [J].
Sekine, Tetsuro ;
Takagi, Ryo ;
Amano, Yasuo ;
Murai, Yasuo ;
Orita, Erika ;
Fukushima, Yoshimitsu ;
Matsumura, Yoshio ;
Kumita, Shin-ichiro .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2018, 17 (01) :13-20
[50]   PRESSURE DIFFERENCE ESTIMATION IN NON-STENOTIC CAROTID BIFURCATION PHANTOMS USING VECTOR FLOW IMAGING [J].
Nguyen, Tin-Quoc ;
Traberg, Marie Sand ;
Olesen, Jacob Bjerring ;
Moshavegh, Ramin ;
Moller-Sorensen, Peter Hasse ;
Lonn, Lars ;
Jensen, Jorgen Arendt ;
Nielsen, Michael Bachmann ;
Hansen, Kristoffer Lindskov .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (02) :346-357