ACCURACY AND PRECISION OF A PLANE WAVE VECTOR FLOW IMAGING METHOD IN THE HEALTHY CAROTID ARTERY

被引:12
作者
Jensen, Jonas [1 ]
Hoyos, Carlos Armando Villagomez [1 ]
Traberg, Marie Sand [1 ]
Olesen, Jacob Bjerring [1 ]
Tomov, Borislav Gueorguiev [1 ]
Moshavegh, Ramin [1 ]
Holbek, Simon [1 ]
Stuart, Matthias Bo [1 ]
Ewertsen, Caroline [2 ]
Hansen, Kristoffer Lindskov [2 ]
Thomsen, Carsten [2 ]
Nielsen, Michael Bachmann [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, Lyngby, Denmark
[2] Copenhagen Univ Hosp, Dept Radiol, Copenhagen, Denmark
关键词
Blood velocity estimation; Vector flow imaging; Plane wave imaging; Complex flow; Carotid artery; BLOOD-FLOW; VELOCITY ESTIMATION; TRANSVERSE OSCILLATION; DOPPLER ULTRASOUND; PEAK VELOCITY; ANGLE; QUANTIFICATION; VELOCIMETRY; SIMULATIONS; DYNAMICS;
D O I
10.1016/j.ultrasmedbio.2018.03.017
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The objective of the study described here was to investigate the accuracy and precision of a plane wave 2-D vector flow imaging (WI) method in laminar and complex blood flow conditions in the healthy carotid artery. The approach was to study (i) the accuracy for complex flow by comparing the velocity field from a computational fluid dynamics (CFD) simulation to VFI estimates obtained from the scan of an anthropomorphic flow phantom and from an in vivo scan; (ii) the accuracy for laminar unidirectional flow in vivo by comparing peak systolic velocities from VFI with magnetic resonance angiography (MRA); (iii) the precision of VFI estimation in vivo at several evaluation points in the vessels. The carotid artery at the bifurcation was scanned using both fast plane wave ultrasound and MRA in 10 healthy volunteers. The MRA geometry acquired from one of the volunteers was used to fabricate an anthropomorphic flow phantom, which was also scanned using the fast plane wave sequence. The same geometry was used in a CFD simulation to calculate the velocity field. Results indicated that similar How patterns and vortices were estimated with CFD and VFI in the phantom for the carotid bifurcation. The root-mean-square difference between CFD and VFI was within 0.12 m/s for velocity estimates in the common carotid artery and the internal branch. The root-mean-square difference was 0.17 m/s in the external branch. For the 10 volunteers, the mean difference between VFI and MRA was-0.17 m/s for peak systolic velocities of laminar flow in vivo. The precision in vivo was calculated as the mean standard deviation (SD) of estimates aligned to the heart cycle and was highest in the center of the common carotid artery (SD = 3.6% for velocity magnitudes and 4.5 degrees for angles) and lowest in the external branch and for vortices (SD = 10.2% for velocity magnitudes and 39 degrees for angles). The results indicate that plane wave VFI measures flow precisely and that estimates are in good agreement with a CFD simulation and MRA. (C) 2018 World Federation for Ultrasound in Medicine & Biology. All rights reserved.
引用
收藏
页码:1727 / 1741
页数:15
相关论文
共 50 条
  • [21] A Vector Flow Imaging Method for Portable Ultrasound Using Synthetic Aperture Sequential Beamforming
    Di Ianni, Tommaso
    Hoyos, Carlos Armando Villagomez
    Ewertsen, Caroline
    Kjeldsen, Thomas Kim
    Mosegaard, Jesper
    Nielsen, Michael Bachmann
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (11) : 1655 - 1665
  • [22] A beamforming method for plane wave Doppler imaging of high flow velocities
    Mansour, Omar
    Poepping, Tamie L.
    Lacefield, James C.
    MEDICAL IMAGING 2016: ULTRASONIC IMAGING AND TOMOGRAPHY, 2016, 9790
  • [23] High-frame rate vector flow imaging of the carotid bifurcation
    Alfredo Goddi
    Chandra Bortolotto
    Ilaria Fiorina
    Maria Vittoria Raciti
    Marianna Fanizza
    Elena Turpini
    Giulia Boffelli
    Fabrizio Calliada
    Insights into Imaging, 2017, 8 : 319 - 328
  • [24] Fourier-based beamforming for 3D plane wave imaging and application in vector flow imaging using selective compounding
    Li, Menghan
    Liang, Siyi
    Lu, Minhua
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (18)
  • [25] First experiences of ultrasound vector flow imaging at the femoropopliteal artery in peripheral arterial disease
    Shchetynska-Marinova, Tetyana
    Gerdes, Laurin
    Hohneck, Anna-Lena
    Winter, Laura
    Amendt, Klaus
    Schwenke, Kay
    Gerken, Andreas L. H.
    Du, Yigang
    Duerschmied, Daniel
    Sigl, Martin
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2023, 52 (06) : 394 - 401
  • [26] Measurement of flow velocity vectors in carotid artery using plane wave imaging with repeated transmit sequence (Sept, 10.1007/s10396-021-01113-2, 2021)
    Hasegawa, Hideyuki
    Mozumi, Michiya
    Omura, Masaaki
    Nagaoka, Ryo
    Saito, Kozue
    JOURNAL OF MEDICAL ULTRASONICS, 2021, 48 (04) : 429 - 429
  • [27] The Influence of Internal Carotid Artery Off-plane Angle on the Hemodynamics of Blood Flow in the Carotid Artery
    AlMomani, Thakir
    Hani, Suleiman Bani
    Smadi, Othman
    Azghoul, Salah
    Kiswani, Laila
    Assarsour, Majdoleen
    JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2019, 13 (03) : 141 - 148
  • [28] Pulse Wave Imaging Coupled With Vector Flow Mapping: A Phantom, Simulation, and In Vivo Study
    Karageorgos, Grigorios Marios
    Apostolakis, Iason-Zacharias
    Nauleau, Pierre
    Gatti, Vittorio
    Weber, Rachel
    Kemper, Paul
    Konofagou, Elisa E.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (07) : 2516 - 2531
  • [29] Ultrasound Vector Flow Imaging Compared with Phase Contrast Magnetic Resonance Imaging for Estimating Blood Flow Velocity and Volume Flow in the Common Carotid Artery
    Du, Yigang
    Ding, Haiyan
    He, Le
    Deng, Linsong
    Yu, Alfred C. H.
    Yiu, Billy Y. S.
    Zhu, Lei
    INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS 2021), 2021,
  • [30] Multidirectional blood flow in the femoral artery via vector flow imaging: Doppler ultrasound imaging insights
    Cohen, Jeremy N.
    Jasiak, Jessica N.
    Nahas, Hassan
    Yu, Alfred C. H.
    Au, Jason S.
    AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2024, 327 (06): : H1467 - H1473