Halving the Volume of AnaConDa: Evaluation of a New Small-Volume Anesthetic Reflector in a Test Lung Model

被引:17
作者
Bomberg, Hagen [1 ]
Meiser, Franziska [1 ]
Daume, Philipp [1 ]
Bellgardt, Martin [2 ]
Volk, Thomas [1 ]
Sessler, Daniel I. [3 ]
Groesdonk, Heinrich V. [1 ]
Meiser, Andreas [1 ]
机构
[1] Univ Saarland, Saarland Univ Med Ctr, Dept Anesthesiol Intens Care Med & Pain Med, Kirrbergerstr 1, D-66421 Homburg, Germany
[2] Ruhr Univ Bochum, Univ Hosp, Kathol Klinikum Bochum, Dept Anesthesiol & Intens Care Med,St Josef Hosp, Bochum, Germany
[3] Cleveland Clin, Anesthesiol Inst, Dept Outcomes Res, Cleveland, OH 44106 USA
关键词
RESPIRATORY-DISTRESS-SYNDROME; CONSERVING DEVICE; ISOFLURANE SEDATION; DEAD SPACE; SEVOFLURANE; SAFETY; FILTER; ICU;
D O I
10.1213/ANE.0000000000003452
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
BACKGROUND: Volatile anesthetics are increasingly used for sedation in intensive care units. The most common administration system is AnaConDa-100 mL (ACD-100; Sedana Medical, Uppsala, Sweden), which reflects volatile anesthetics in open ventilation circuits. AnaConDa-50 mL (ACD-50) is a new device with half the volumetric dead space. Carbon dioxide (CO2) can be retained with both devices. We therefore compared the CO2 elimination and isoflurane reflection efficiency of both devices. METHODS: A test lung constantly insufflated with CO2 was ventilated with a tidal volume of 500 mL at 10 breaths/min. End-tidal CO2 (Etco(2)) partial pressure was measured using 3 different devices: a heat-and-moisture exchanger (HME, 35 mL), ACD-100, and ACD-50 under 4 different experimental conditions: ambient temperature pressure (ATP), body temperature pressure saturated (BTPS) conditions, BTPS with 0.4 Vol% isoflurane (ISO-0.4), and BTPS with 1.2 Vol% isoflurane. Fifty breaths were recorded at 3 time points (n = 150) for each device and each condition. To determine device dead space, we adjusted the tidal volume to maintain normocapnia (n = 3), for each device. Thereafter, we determined reflection efficiency by measuring isoflurane concentrations at infusion rates varying from 0.5 to 20 mL/h (n = 3), for each device. RESULTS: Etco(2) was consistently greater with ACD-100 than with ACD-50 and HME (ISO-0.4, mean +/- standard deviations: ACD-100, 52.4 +/- 0.8; ACD-50, 44.4 +/- 0.8; HME, 40.1 +/- 0.4 mm Hg; differences of means of Etco(2) [respective 95% confidence intervals]: ACD-100 - ACD-50, 8.0 [7.9-8.1] mm Hg, P < .001; ACD-100 - HME, 12.3 [12.2-12.4] mm Hg, P < .001; ACD-50 - HME, 4.3 [4.2-4.3] mm Hg, P < .001). It was greatest under ATP, less under BTPS, and least with ISO-0.4 and BTPS with 1.2 Vol% isoflurane. In addition to the 100 or 50 mL "volumetric dead space" of each AnaConDa, "reflective dead space" was 40 mL with ACD-100 and 25 mL with ACD-50 when using isoflurane. Isoflurane reflection was highest under ATP. Under BTPS with CO2 insufflation and isoflurane concentrations around 0.4 Vol%, reflection efficiency was 93% with ACD-100 and 80% with ACD-50. CONCLUSIONS: Isoflurane reflection remained sufficient with the ACD-50 at clinical anesthetic concentrations, while CO2 elimination was improved. The ACD-50 should be practical for tidal volumes as low as 200 mL, allowing lung-protective ventilation even in small patients.
引用
收藏
页码:371 / 379
页数:9
相关论文
共 27 条
  • [1] Baron R., 2015, GMS German Medical Science, V13, pDoc19
  • [2] The predictive performance of a pharmacokinetic model for manually adjusted infusion of liquid sevofluorane for use with the Anesthetic-Conserving Device (AnaConDa):: A clinical study
    Belda, Javier F.
    Soro, Marina
    Badenes, Rafael
    Meiser, Andreas
    Garcia, Maria Luisa
    Aguilar, Gerardo
    Marti, Francisco J.
    [J]. ANESTHESIA AND ANALGESIA, 2008, 106 (04) : 1207 - 1214
  • [3] Survival after long-term isoflurane sedation as opposed to intravenous sedation in critically ill surgical patients Retrospective analysis
    Bellgardt, Martin
    Bomberg, Hagen
    Herzog-Niescery, Jenny
    Dasch, Burkhard
    Vogelsang, Heike
    Weber, Thomas P.
    Steinfort, Claudia
    Uhl, Waldemar
    Wagenpfeil, Stefan
    Volk, Thomas
    Meiser, Andreas
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2016, 33 (01) : 6 - 13
  • [4] AnaConDa® reflection filter:: Bench and patient evaluation of safety and volatile anesthetic conservation
    Berton, Jerome
    Sargentini, Cyril
    Nguyen, Jean-Luc
    Belii, Adrian
    Beydon, Laurent
    [J]. ANESTHESIA AND ANALGESIA, 2007, 104 (01) : 130 - 134
  • [5] A novel device for target controlled administration and reflection of desflurane - the Mirus™
    Bomberg, H.
    Glas, M.
    Groesdonk, V. H.
    Bellgardt, M.
    Schwarz, J.
    Volk, T.
    Meiser, A.
    [J]. ANAESTHESIA, 2014, 69 (11) : 1241 - 1250
  • [6] Bomberg H, 2018, J CLIN MONIT COMPUT
  • [7] Bomberg H, 2016, J CLIN MONIT COMPUT
  • [8] Clinical practice guidelines for evidence-based management of sedoanalgesia in critically ill adult patients
    Celis-Rodriguez, E.
    Birchenall, C.
    de la Cal, M. A.
    Arellano, G. Castorena
    Hernandez, A.
    Ceraso, D.
    Diaz Cortes, J. C.
    Duenas Castell, C.
    Jimenez, E. J.
    Meza, J. C.
    Munoz Martinez, T.
    Sosa Garcia, J. O.
    Pacheco Tovar, C.
    Palizas, F.
    Pardo Oviedo, J. M.
    Pinilla, D-I.
    Raffan-Sanabria, F.
    Raimondir, N.
    Righy Shinotsuka, C.
    Suarez, M.
    Ugarte, S.
    Rubiano, S.
    [J]. MEDICINA INTENSIVA, 2013, 37 (08) : 519 - 574
  • [9] Impact of the Anesthetic Conserving Device on Respiratory Parameters and Work of Breathing in Critically Ill Patients under Light Sedation with Sevoflurane
    Chabanne, Russell
    Perbet, Sebastien
    Futier, Emmanuel
    Ben Said, Nordine Ait
    Jaber, Samir
    Bazin, Jean-Etienne
    Pereira, Bruno
    Constantin, Jean-Michel
    [J]. ANESTHESIOLOGY, 2014, 121 (04) : 808 - 816
  • [10] Tidal Volume Delivery From ICU Ventilators at BTPS Conditions: A Bench Study
    Duchateau, Paul
    Guerin, Claude
    [J]. RESPIRATORY CARE, 2013, 58 (04) : 623 - 632