Efficacy and safety of artificial ascites in assisting percutaneous microwave ablation of hepatic tumours adjacent to the gastrointestinal tract

被引:80
作者
Zhang, Min [1 ,2 ]
Liang, Ping [1 ]
Cheng, Zhi-Gang [1 ]
Yu, Xiao-Ling [1 ]
Han, Zhi-Yu [1 ]
Yu, Jie [1 ]
机构
[1] Chinese Peoples Liberat Army Gen Hosp, Dept Intervent Ultrasound, Beijing 100853, Peoples R China
[2] Wulumuqi Gen Hosp Lanzhou Mil Reg, Dept Ultrasound, Urumqi, Peoples R China
基金
中国国家自然科学基金;
关键词
Artificial ascites; catheter ablation; interventional ultrasound; liver neoplasms; microwaves; LIVER-CANCER ADJACENT; RADIOFREQUENCY ABLATION; HEPATOCELLULAR-CARCINOMA; THERMAL ABLATION; PORCINE MODEL; COMPLICATIONS; MULTICENTER; ULTRASOUND; METASTASES;
D O I
10.3109/02656736.2014.891765
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: This study assessed the efficacy and safety of artificial ascites in assisting ultrasound-guided percutaneous microwave (MW) ablation of hepatic tumours adjacent to the gastrointestinal tract. Materials and methods: In total, 36 patients with 36 hepatic malignancies who underwent the introduction of artificial ascites before ultrasound-guided percutaneous MW ablation were included in this retrospective study. The separation success rate of the artificial ascites, the technique effectiveness of the MW ablation, local tumour progression and complications were assessed. Results: The separation success rate of the artificial ascites for 36 hepatic tumours adjacent to the gastrointestinal tract was 88.9% (32/36). The technical effectiveness of MW ablation in 32 cases with successful separation was 96.9% (31/32). During follow-up (mean, 12.1 +/- 7.2 months), local tumour progression was found in five of 31 patients (16.1%). One patient experienced a major complication (infection of the hepatic ablation zone). Conclusions: Ultrasound-guided percutaneous MW ablation assisted by artificial ascites is a safe and effective method for the treatment of primary and metastatic hepatic tumours adjacent to the gastrointestinal tract and can achieve good local control of such tumours.
引用
收藏
页码:134 / 141
页数:8
相关论文
共 33 条
[1]   Microwaves create larger ablations than radiofrequency when controlled for power in ex vivo tissue [J].
Andreano, A. ;
Huang, Yu ;
Meloni, M. Franca ;
Lee, Fred T., Jr. ;
Brace, Christopher .
MEDICAL PHYSICS, 2010, 37 (06) :2967-2973
[2]   Management of Hepatocellular Carcinoma: An Update [J].
Bruix, Jordi ;
Sherman, Morris .
HEPATOLOGY, 2011, 53 (03) :1020-1022
[3]   Radiofrequency thermal ablation of liver tumors [J].
Buscarini, E ;
Savoia, A ;
Brambilla, G ;
Menozzi, F ;
Reduzzi, L ;
Strobel, D ;
Hänsler, J ;
Buscarini, L ;
Gaiti, L ;
Zambelli, A .
EUROPEAN RADIOLOGY, 2005, 15 (05) :884-894
[4]   Hepatic Resection Versus Radiofrequency Ablation for Very Early Stage Hepatocellular Carcinoma: A Markov Model Analysis [J].
Cho, Yun Ku ;
Kim, Jae Kyun ;
Kim, Wan Tae ;
Chung, Jin Wook .
HEPATOLOGY, 2010, 51 (04) :1284-1290
[5]   Real-Time Contrast-Enhanced Ultrasound - a New Simple Tool for Detection of Peritoneal-Pleural Communications in Hepatic Hydrothorax [J].
Foschi, F. G. ;
Piscaglia, F. ;
Pompili, M. ;
Corbelli, C. ;
Marano, G. ;
Righini, R. ;
Alvisi, V. ;
Gasbarrini, C. ;
Bolondi, L. ;
Bernardi, M. ;
Stefanini, C. F. .
ULTRASCHALL IN DER MEDIZIN, 2008, 29 (05) :538-542
[6]   EFFICACY OF LAPAROSCOPIC RADIOFREQUENCY ABLATION FOR HEPATOCELLULAR CARCINOMA COMPARED TO PERCUTANEOUS RADIOFREQUENCY ABLATION WITH ARTIFICIAL ASCITES [J].
Hirooka, Masashi ;
Kisaka, Yoshiyasu ;
Uehara, Takahide ;
Ishida, Kiyotaka ;
Kumagi, Teru ;
Watanabe, Yuji ;
Abe, Masanori ;
Matsuura, Bunzo ;
Hiasa, Yoichi ;
Onji, Morikazu .
DIGESTIVE ENDOSCOPY, 2009, 21 (02) :82-86
[7]   Efficacy and feasibility of radiofrequency ablation for liver metastases from gastric adenocarcinoma [J].
Kim, Hye Ryun ;
Cheon, Seong Ha ;
Lee, Kwang-Hun ;
Ahn, Jung Ryun ;
Jeung, Hei-Cheul ;
Lee, Sung Sook ;
Chung, Hyun Cheol ;
Noh, Sung Hoon ;
Rha, Sun Young .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2010, 26 (04) :305-315
[8]   Intrahepatic recurrence after percutaneous radiofrequency ablation of hepatocellular carcinoma: Analysis of the pattern and risk factors [J].
Kim, Young-sun ;
Rhim, Hyunchul ;
Cho, On Koo ;
Koh, Byung Hee ;
Kim, Yongsoo .
EUROPEAN JOURNAL OF RADIOLOGY, 2006, 59 (03) :432-441
[9]   Does Artificial Ascites Induce the Heat-Sink Phenomenon during Percutaneous Radiofrequency Ablation of the Hepatic Subcapsular Area?: an in vivo Experimental Study Using a Rabbit Model [J].
Kim, Young-sun ;
Rhim, Hyunchul ;
Choi, Dongil ;
Lim, Hyo K. .
KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (01) :43-50
[10]   Complications of radiofrequency ablation for hepatocellular carcinoma in a multicenter study: An analysis of 16 346 treated nodules in 13 283 patients [J].
Koda, Masahiko ;
Murawaki, Yoshikazu ;
Hirooka, Yasuaki ;
Kitamoto, Mikiya ;
Ono, Masafumi ;
Sakaeda, Hiroshi ;
Joko, Kouji ;
Sato, Shuichi ;
Tamaki, Katsuyoshi ;
Yamasaki, Takahiro ;
Shibata, Hiroshi ;
Shimoe, Toshinari ;
Matsuda, Tadakazu ;
Toshikuni, Nobuyuki ;
Fujioka, Shin-ichi ;
Ohmoto, Kenji ;
Nakamura, Shinichiro ;
Kariyama, Kazuya ;
Aikata, Hiroshi ;
Kobayashi, Yoshiyuki ;
Tsutsui, Akemi .
HEPATOLOGY RESEARCH, 2012, 42 (11) :1058-1064