DETERMINATION OF THE BEST ELECTRODE POSITION FOR RECORDING OF THE DIAPHRAGM COMPOUND MUSCLE ACTION POTENTIAL

被引:24
作者
Dionne, Annie [1 ]
Parkes, Anthony [2 ]
Engler, Beata [2 ]
Watson, Bradley V. [2 ]
Nicolle, Michael W. [2 ]
机构
[1] Univ Laval, Hop Enfant Jesus, Dept Clin Neurol Sci, Quebec City, PQ G1J 1Z4, Canada
[2] Univ Western Ontario, Dept Clin Neurol Sci, London, ON, Canada
关键词
diaphragm; electrode position; electrophysiology; phrenic nerve; technique; PHRENIC-NERVE CONDUCTION; STIMULATION;
D O I
10.1002/mus.21290
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
To determine the optimal recording site for phrenic nerve conduction studies, six different recording techniques were compared in 11 healthy volunteers (22 phrenic nerves). The mean diaphragm compound muscle action potential (CMAP) amplitude, side-to-side difference, and the number of studies with a false-positive result (CMAP amplitude <0.30 mV) were compared for each technique. The largest amplitude (0.65 +/- 0.23 mV, range 0.30-1.2 mV) with good right-left agreement (mean difference 0.15 mV) and no false positives was obtained using technique 1, where the G1 electrode was positioned 5 cm above the xiphoid process and G2 16 cm from G1 along the costal margin. This was also the easiest technique to perform. It does not require rib counting, which may be difficult and inaccurate, especially in overweight patients. At least one false positive occurred with each of the remaining five techniques. Muscle Nerve 40: 37-41, 2009
引用
收藏
页码:37 / 41
页数:5
相关论文
共 13 条
[1]  
[Anonymous], 2002, AM J RESP CRIT CARE, V166, P518
[2]  
BOLTON C, 2003, NEUROLOGY BREATHING
[3]   AAEM MINIMONOGRAPH-40 - CLINICAL NEUROPHYSIOLOGY OF THE RESPIRATORY SYSTEM [J].
BOLTON, CF .
MUSCLE & NERVE, 1993, 16 (08) :809-818
[4]   PHRENIC-NERVE CONDUCTION STUDY IN NORMAL SUBJECTS [J].
CHEN, R ;
COLLINS, S ;
REMTULLA, H ;
PARKES, A ;
BOLTON, CF .
MUSCLE & NERVE, 1995, 18 (03) :330-335
[5]   PHRENIC NERVE CONDUCTION IN MAN [J].
DAVIS, JN .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1967, 30 (05) :420-&
[6]  
Field D., 2006, FIELDS ANATOMY PALPA
[7]   Diaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation [J].
Luo, YM ;
Polkey, MI ;
Johnson, LC ;
Lyall, RA ;
Harris, ML ;
Green, M ;
Moxham, J .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (06) :2089-2099
[8]  
MACLEAN IC, 1981, ARCH PHYS MED REHAB, V62, P70
[9]   ELECTROPHYSIOLOGIC EVALUATION OF DIAPHRAGM BY TRANS-CUTANEOUS PHRENIC-NERVE STIMULATION [J].
MARKAND, ON ;
KINCAID, JC ;
POURMAND, RA ;
MOORTHY, SS ;
KING, RD ;
MAHOMED, Y ;
BROWN, JW .
NEUROLOGY, 1984, 34 (05) :604-614
[10]   Phrenic nerve conduction studies: Technical aspects and normative data [J].
Resman-Gaspersc, Anita ;
Podnar, Simon .
MUSCLE & NERVE, 2008, 37 (01) :36-41