In vitro comparison of biomechanical characteristics of sagittal split osteotomy fixation techniques

被引:54
作者
Oezden, B.
Alkan, A.
Arici, S.
Erdem, E.
机构
[1] Ondokuz Mayis Univ, Fac Dent, Dept Oral & Maxillofacial Surg, Samsun, Turkey
[2] Ankara Univ, Fac Dent, Dept Oral & Maxillofacial Surg, TR-06100 Ankara, Turkey
[3] Ondokuz Mayis Univ, Fac Dent, Dept Orthodont, Samsun, Turkey
关键词
sagittal split osteotomy; rigid fixation; biomechanical stability;
D O I
10.1016/j.ijom.2006.03.001
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of the present study was to compare the biomechanical stability of 10 different fixation methods used in sagittal split osteotomy. Twenty-five fresh sheep mandibles were stripped of all soft tissues and sectioned at the midline. A sagittal split osteotomy with 5 mm advancement was performed on each hemimandible. The hemimandibles were randomly divided into 10 groups of 5, and then fixed with 5 different bicortical screws, 4 different miniplates with or without bicortical screws, and 1 resorbable screw configuration. All specimens were mounted on a specially designed 3-point biomechanical test model and compression loads were applied using the Lloyd LRX testing machine until 3 mm displacement was reached. Load/displacement data were gathered and compared using the Mann-Whitney U-test with Bonferroni correction (P < 0.01). The 3 bicortical screws in an inverted backward-L pattern provided the most biomechanical stability of the screw patterns tested. The miniplate fixed obliquely with 2 bicortical screws in the proximal segment provided the most biomechanical stability of the miniplate groups.
引用
收藏
页码:837 / 841
页数:5
相关论文
共 29 条
[1]   INVITRO STRENGTH ANALYSIS OF SAGITTAL SPLIT OSTEOTOMY FIXATION - NONCOMPRESSION MONOCORTICAL PLATES VERSUS BICORTICAL POSITION SCREWS [J].
ANUCUL, B ;
WAITE, PD ;
LEMONS, JE .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1992, 50 (12) :1295-1299
[2]   COMPARATIVE-EVALUATION OF SCREW CONFIGURATION ON THE STABILITY OF THE SAGITTAL SPLIT OSTEOTOMY [J].
ARDARY, WC ;
TRACY, DJ ;
BROWNRIDGE, GW ;
URATA, MM .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 68 (02) :125-129
[3]   Preliminary investigation of the biomechanics of internal fixation of sagittal split osteotomies with miniplates using a newly designed in vitro testing model [J].
Armstrong, JEA ;
Lapointe, HJ ;
Hogg, NJV ;
Kwok, AD .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 59 (02) :191-195
[4]   A comparison of skeletal stability after mandibular advancement and use of two rigid internal fixation techniques [J].
Blomqvist, JE ;
Ahlborg, G ;
Isaksson, S ;
Svartz, K .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1997, 55 (06) :568-574
[5]   Stabilisation of sagittal split advancement osteotomies with miniplates: a prospective multicentre study with two-year follow-up - Part III - Condylar remodelling and resorption [J].
Borstlap, WA ;
Stoelinga, PJW ;
Hoppenreijs, TJM ;
van't Hof, MA .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2004, 33 (07) :649-655
[6]   Comparison of stability of absorbable and titanium plate and screw fixation for sagittal split ramus osteotomy [J].
Dolanmaz, D ;
Uckan, S ;
Isik, K ;
Saglam, H .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2004, 42 (02) :127-132
[7]   Skeletal stability after mandibular advancement with rigid versus wire fixation [J].
Dolce, C ;
Van Sickels, JE ;
Bays, RA ;
Rugh, JD .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2000, 58 (11) :1219-1227
[8]   Biomechanical testing of resorbable screws used for mandibular sagittal split osteotomies [J].
Eppley, BL ;
Sarver, D ;
Pietrzak, B .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (12) :1431-1435
[9]  
Foley W L, 1992, Int J Adult Orthodon Orthognath Surg, V7, P147
[10]   INTERNAL SCREW FIXATION - COMPARISON OF PLACEMENT PATTERN AND RIGIDITY [J].
FOLEY, WL ;
FROST, DE ;
PAULIN, WB ;
TUCKER, MR .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1989, 47 (07) :720-723