Implant surface roughness and bone healing: a systematic review

被引:407
作者
Shalabi, M. M.
Gortemaker, A.
Van't Hof, M. A.
Jansen, J. A.
Creugers, N. H. J.
机构
[1] Radboud Univ Nijmegen Med Ctr, Dept Periodontol & Biomat, Coll Dent Sci, NL-6500 HB Nijmegen, Netherlands
[2] Radboud Univ Nijmegen Med Ctr, Dept Oral Funct & Prosthet Dent, Coll Dent Sci, NL-6500 HB Nijmegen, Netherlands
关键词
implant; surface roughness; bone healing; systematic review;
D O I
10.1177/154405910608500603
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
A systematic review was performed on studies investigating the effects of implant surface roughness on bone response and implant fixation. We searched the literature using MEDLINE from 1953 to 2003. Inclusion criteria were: (1) abstracts of animal studies investigating implant surface roughness and bone healing; (2) observations of three-month bone healing, surface topography measurements, and biomechanical tests; (3) provision of data on surface roughness, bone-to-implant contact, and biomechanical test values. The literature search revealed 5966 abstracts. There were 470, 23, and 14 articles included in the first, second, and third selection steps, respectively. Almost all papers showed an enhanced bone-to-implant contact with increasing surface roughness. Six comparisons were significantly positive for the relationship of bone-to-implant contact and surface roughness. Also, a significant relation was found between push-out strength and surface roughness. Unfortunately, the eventually selected studies were too heterogeneous for inference of data. Nevertheless, the statistical analysis on the available data provided supportive evidence for a positive relationship between bone-to-implant contact and surface roughness.
引用
收藏
页码:496 / 500
页数:5
相关论文
共 30 条
[11]  
Gotfredsen K, 1992, Clin Oral Implants Res, V3, P77, DOI 10.1034/j.1600-0501.1992.030205.x
[12]   An in vivo study of bone response to implants topographically modified by laser micromachining [J].
Hallgren, C ;
Reimers, H ;
Chakarov, D ;
Gold, J ;
Wennerberg, A .
BIOMATERIALS, 2003, 24 (05) :701-710
[13]  
Hallgren C, 2001, J BIOMED MATER RES, V57, P485, DOI 10.1002/1097-4636(20011215)57:4<485::AID-JBM1194>3.0.CO
[14]  
2-1
[15]   Quality of dental implants [J].
Jokstad, A ;
Braegger, U ;
Brunski, JB ;
Carr, AB ;
Naert, I ;
Wennerberg, A .
INTERNATIONAL DENTAL JOURNAL, 2003, 53 (06) :409-443
[16]  
Lee JJ, 2000, J ORAL MAXIL SURG, V58, P1372, DOI 10.1053/joms.2000.18269
[17]  
London RM, 2002, INT J ORAL MAX IMPL, V17, P369
[18]   Variation in surface texture measurements [J].
Macdonald, W ;
Campbell, P ;
Fisher, J ;
Wennerberg, A .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 70B (02) :262-269
[19]  
Morra M, 2003, INT J ORAL MAX IMPL, V18, P40
[20]  
Novaes AB, 2002, INT J ORAL MAX IMPL, V17, P377