Automated solid sample dissolution coupled with sugaring-out homogenous liquid-liquid extraction. Application for the analysis of throat lozenge samples

被引:10
|
作者
Shishov, Andrey [1 ]
Nechaeva, Dania [1 ]
Moskvin, Leonid [1 ]
Andruch, Vasil [2 ]
Bulatov, Andrey [1 ]
机构
[1] St Petersburg State Univ, Inst Chem, RU-198504 St Petersburg, Russia
[2] Pavol Jozef Safarik Univ, Dept Analyt Chem, SK-04154 Kosice, Slovakia
关键词
Automation; Sugaring-out homogenous liquid-liquid extraction; Flow analysis; Stepwise injection analysis; Pharmaceuticals; ATOMIC-ABSORPTION-SPECTROMETRY; HUMAN URINE SAMPLES; FLUORESCENCE DETECTION; FILTERS DETERMINATION; METAL DETERMINATION; MICROEXTRACTION; CHROMATOGRAPHY; PRECONCENTRATION; WATER; FERMENTATION;
D O I
10.1016/j.molliq.2017.03.022
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
A novel automated procedure for analysis of solid samples based on the on-line dissolution of solid sample and sugaring-out reagent in water-acetonitrile mixture coupled with.sugaring-out homogenous liquid-liquid extraction was developed. The procedure was performed in a mixing chamber of a stepwise injection analysis manifold. The performance of the suggested approach was demonstrated by the determination of 2,4-dichlorobenzyl alcohol, amylmetacresol, Yellow Orange S, Azo Rubine and Ponceau 4R in pharmaceutical samples. After phase separation, the upper acetonitrile phase containing 2,4-dichlorobenzyl alcohol, amylmetacresol and lower aqueous phase containing artificial dyes were sequentially analyzed. Under optimal experimental conditions the linear ranges were found to be 0.1-10 mg L-1 for 2,4 dichlorobenzyl alcohol, 0.5-50 mg L-1 for amylmetacresol, and 1-100 mg L-1 for artificial dyes. The sample throughput was 10 hi(-1). The proposed method was successfully applied for the automated analysis of commercial throat lozenges and the analytical results agreed fairly well with the results obtained by reference HPLC-UV method. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 155
页数:7
相关论文
共 50 条
  • [21] Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry
    Jemal, M
    Teitz, D
    Ouyang, Z
    Khan, S
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 501 - 508
  • [22] Comparison of salting-out and sugaring-out liquid-liquid extraction methods for the partition of 10-hydroxy-2-decenoic acid in royal jelly and their co-extracted protein content
    Tu, Xijuan
    Sun, Fanyi
    Wu, Siyuan
    Liu, Weiyi
    Gao, Zhaosheng
    Huang, Shaokang
    Chen, Wenbin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1073 : 90 - 95
  • [23] Combination of Counter Current Salting-Out Homogenous Liquid-Liquid Extraction with Dispersive Liquid-Liquid Microextraction for the High-Performance Liquid Chromatographic Determination of Environmental Estrogens in Water Samples
    Shi, Zhihong
    Huai, Qingru
    Li, Xinye
    Ma, Hongyu
    Zhou, Can
    Chu, Xiaoxue
    Zhang, Hongyi
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2020, 58 (02) : 171 - 177
  • [24] Development of counter current salting-out homogenous liquid-liquid extraction for isolation and preconcentration of some pesticides from aqueous samples
    Farajzadeh, Mir Ali
    Feriduni, Behruz
    Mogaddam, Mohammad Reza Afshar
    ANALYTICA CHIMICA ACTA, 2015, 885 : 122 - 131
  • [25] Automated on-line liquid-liquid extraction system for temporal mass spectrometric analysis of dynamic samples
    Hsieh, Kai-Ta
    Liu, Pei-Han
    Urban, Pawel L.
    ANALYTICA CHIMICA ACTA, 2015, 894 : 35 - 43
  • [26] Development of a new extraction method based on counter current salting-out homogenous liquid-liquid extraction followed by dispersive liquid-liquid microextraction: Application for the extraction and preconcentration of widely used pesticides from fruit juices
    Farajzadeh, Mir Ali
    Feriduni, Behruz
    Mogaddam, Mohammad Reza Afshar
    TALANTA, 2016, 146 : 772 - 779
  • [27] Fully automated 96-well liquid-liquid extraction for analysis of biological samples by liquid chromatography with tandem mass spectrometry
    Peng, SX
    Branch, TM
    King, SL
    ANALYTICAL CHEMISTRY, 2001, 73 (03) : 708 - 714
  • [28] Development of sodium hydroxide-induced homogenous liquid-liquid extraction-effervescent assisted dispersive liquid-liquid microextraction based on deep eutectic solvents; Application in the extraction of phytosterols from cow cream samples
    Nemati, Mahboob
    Tuzen, Mustafa
    Altunay, Nail
    Farajzdeh, Mir Ali
    Abdi, Fardin
    Mogaddam, Mohammad Reza Afshar
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 106
  • [29] Salting-out assisted liquid-liquid extraction (SALLE): Principle , optimization, and applications in blood sample analysis
    Yao, Jean Simon Thodhekes
    Ladner, Yoann
    Amin, N. 'Cho Christophe
    Perrin, Catherine
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2025, 257
  • [30] A novel dual-valve sequential injection manifold (DV-SIA) for automated liquid-liquid extraction. Application for the determination of picric acid
    Skrlikova, Jana
    Andruch, Vasil
    Sklenarova, Hana
    Chocholous, Petr
    Solich, Petr
    Balogh, Ioseph S.
    ANALYTICA CHIMICA ACTA, 2010, 666 (1-2) : 55 - 61