Evaluation of auto-planning in IMRT and VMAT for head and neck cancer

被引:29
|
作者
Ouyang, Zi [1 ]
Shen, Zhilei Liu [1 ]
Murray, Eric [1 ]
Kolar, Matt [1 ]
LaHurd, Danielle [1 ]
Yu, Naichang [1 ]
Joshi, Nikhil [1 ]
Koyfman, Shiomo [1 ]
Bzdusek, Karl [2 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44106 USA
[2] Philips Healthcare Inc, Fitchburg, WI USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2019年 / 20卷 / 07期
关键词
auto-planning; head and neck; IMRT; step and shoot; VMAT; QUALITY; DVH;
D O I
10.1002/acm2.12652
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purposes of this work are to (a) investigate whether the use of auto-planning and multiple iterations improves quality of head and neck (HN) radiotherapy plans; (b) determine whether delivery methods such as step-and-shoot (SS) and volumetric modulated arc therapy (VMAT) impact plan quality; (c) report on the observations of plan quality predictions of a commercial feasibility tool. Materials and methods Twenty HN cases were retrospectively selected from our clinical database for this study. The first ten plans were used to test setting up planning goals and other optimization parameters in the auto-planning module. Subsequently, the other ten plans were replanned with auto-planning using step-and-shoot (AP-SS) and VMAT (AP-VMAT) delivery methods. Dosimetric endpoints were compared between the clinical plans and the corresponding AP-SS and AP-VMAT plans. Finally, predicted dosimetric endpoints from a commercial program were assessed. Results All AP-SS and AP-VMAT plans met the clinical dose constraints. With auto-planning, the dose coverage of the low dose planning target volume (PTV) was improved while the dose coverage of the high dose PTV was maintained. Compared to the clinical plans, the doses to critical organs, such as the brainstem, parotid, larynx, esophagus, and oral cavity were significantly reduced in the AP-VMAT (P < 0.05); the AP-SS plans had similar homogeneity indices (HI) and conformality indices (CI) and the AP-VMAT plans had comparable HI and improved CI. Good agreement in dosimetric endpoints between predictions and AP-VMAT plans were observed in five of seven critical organs. Conclusion With improved planning quality and efficiency, auto-planning module is an effective tool to enable planners to generate HN IMRT plans that are meeting institution specific planning protocols. DVH prediction is feasible in improving workflow and plan quality.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [41] Evaluation of a Knowledge-Based Planning Solution for Head and Neck Cancer
    Tol, Jim P.
    Delaney, Alexander R.
    Dahele, Max
    Slotman, Ben J.
    Verbakel, Wilko F. A. R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 91 (03): : 612 - 620
  • [42] Dosimetric comparison of MR-linac-based IMRT and conventional VMAT treatment plans for prostate cancer
    Mendes, Vanessa Da Silva
    Nierer, Lukas
    Li, Minglun
    Corradini, Stefanie
    Reiner, Michael
    Kamp, Florian
    Niyazi, Maximilian
    Kurz, Christopher
    Landry, Guillaume
    Belka, Claus
    RADIATION ONCOLOGY, 2021, 16 (01)
  • [43] An IMRT/VMAT Technique for Nonsmall Cell Lung Cancer
    Zhao, Nan
    Yang, Ruijie
    Wang, Junjie
    Zhang, Xile
    Li, Jinna
    BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [44] Clinical validation and benchmarking of knowledge-based IMRT and VMAT treatment planning in pelvic anatomy
    Hussein, Mohammad
    South, Christopher P.
    Barry, Miriam A.
    Adams, Elizabeth J.
    Jordan, Tom J.
    Stewart, Alexandra J.
    Nisbet, Andrew
    RADIOTHERAPY AND ONCOLOGY, 2016, 120 (03) : 473 - 479
  • [45] Comparing step-and-shoot IMRT with dynamic helical tomotherapy IMRT plans for head-and-neck cancer
    Van Vulpen, M
    Field, C
    Raaijmakers, CPJ
    Parliament, MB
    Terhaard, CHJ
    MacKenzie, MA
    Scrimger, R
    Lagendijk, JJW
    Fallone, BG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (05): : 1535 - 1539
  • [46] Recommendations for treatment with IMRT for prostate and head-neck cancer
    del Carmen Maceira Rozas M.
    Liste T.R.
    García Caeiro Á.L.
    Comesaña J.G.
    Clinical & Translational Oncology, 2006, 8 (4) : 262 - 265
  • [47] Evaluation of a commercial DIR platform for contour propagation in prostate cancer patients treated with IMRT/VMAT
    Hammers, Jacob E.
    Pirozzi, Sara
    Lindsay, Daniel
    Kaidar-Person, Orit
    Tan, Xianming
    Chen, Ronald C.
    Das, Shiva K.
    Mavroidis, Panayiotis
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2020, 21 (02): : 14 - 25
  • [48] A study on conventional IMRT and RapidArc treatment planning techniques for head and neck cancers
    Kumar, S. A. Syam
    Vivekanandan, Nagarajan
    Sriram, Padmanaban
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2012, 17 (03) : 168 - 175
  • [49] AN EVALUATIONOF VOLUMETRICINTENSITY-MODULATED ARC THERAPY AND CONVENTIONAL IMRT IN HEAD AND NECK CANCER
    Jakubovskij, E.
    Rudgalvyte, M.
    Viciene, R. Stepona
    Grybauskas, M.
    Sendiuliene, D.
    MEDICAL PHYSICS IN THE BALTIC STATES, 2015, : 26 - 30
  • [50] Experimental validation of deterministic Acuros XB algorithm for IMRT and VMAT dose calculations with the Radiological Physics Center's head and neck phantom
    Han, Tao
    Mourtada, Firas
    Kisling, Kelly
    Mikell, Justin
    Followill, David
    Howell, Rebecca
    MEDICAL PHYSICS, 2012, 39 (04) : 2193 - 2202