Evaluation of auto-planning in IMRT and VMAT for head and neck cancer

被引:29
|
作者
Ouyang, Zi [1 ]
Shen, Zhilei Liu [1 ]
Murray, Eric [1 ]
Kolar, Matt [1 ]
LaHurd, Danielle [1 ]
Yu, Naichang [1 ]
Joshi, Nikhil [1 ]
Koyfman, Shiomo [1 ]
Bzdusek, Karl [2 ]
Xia, Ping [1 ]
机构
[1] Cleveland Clin, Dept Radiat Oncol, Cleveland, OH 44106 USA
[2] Philips Healthcare Inc, Fitchburg, WI USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2019年 / 20卷 / 07期
关键词
auto-planning; head and neck; IMRT; step and shoot; VMAT; QUALITY; DVH;
D O I
10.1002/acm2.12652
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose The purposes of this work are to (a) investigate whether the use of auto-planning and multiple iterations improves quality of head and neck (HN) radiotherapy plans; (b) determine whether delivery methods such as step-and-shoot (SS) and volumetric modulated arc therapy (VMAT) impact plan quality; (c) report on the observations of plan quality predictions of a commercial feasibility tool. Materials and methods Twenty HN cases were retrospectively selected from our clinical database for this study. The first ten plans were used to test setting up planning goals and other optimization parameters in the auto-planning module. Subsequently, the other ten plans were replanned with auto-planning using step-and-shoot (AP-SS) and VMAT (AP-VMAT) delivery methods. Dosimetric endpoints were compared between the clinical plans and the corresponding AP-SS and AP-VMAT plans. Finally, predicted dosimetric endpoints from a commercial program were assessed. Results All AP-SS and AP-VMAT plans met the clinical dose constraints. With auto-planning, the dose coverage of the low dose planning target volume (PTV) was improved while the dose coverage of the high dose PTV was maintained. Compared to the clinical plans, the doses to critical organs, such as the brainstem, parotid, larynx, esophagus, and oral cavity were significantly reduced in the AP-VMAT (P < 0.05); the AP-SS plans had similar homogeneity indices (HI) and conformality indices (CI) and the AP-VMAT plans had comparable HI and improved CI. Good agreement in dosimetric endpoints between predictions and AP-VMAT plans were observed in five of seven critical organs. Conclusion With improved planning quality and efficiency, auto-planning module is an effective tool to enable planners to generate HN IMRT plans that are meeting institution specific planning protocols. DVH prediction is feasible in improving workflow and plan quality.
引用
收藏
页码:39 / 47
页数:9
相关论文
共 50 条
  • [21] Optimal VMAT Delivery for Elekta MLC Beam Modulator: A Study of Collimator Rotation for Head and Neck Planning
    Murtaza, Ghulam
    Mehmood, Shahid
    Favretto, Maria Silvia
    Cora, Stefania
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2020, 51 (02) : 289 - 298
  • [22] Cobalt compensator-based IMRT device: A treatment planning study of head and neck cases
    Sengupta, Bishwambhar
    Oh, Kyuhak
    Sponseller, Patricia
    Zaki, Peter
    Eastman, Boryana
    Dinh, Tru-Khang T.
    Cardenas, Carlos E.
    Court, Laurence E.
    Parvathaneni, Upendra
    Ford, Eric
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 106
  • [23] Optimisation of user-selectable volumetric modulated arc therapy (VMAT) planning parameters: VMAT arcs for prostate and head-and-neck cancers
    Murtaza, Ghulam
    Gillani, Zaheer Abbas
    Mehmood, Shahid
    Rehman, Jalil Ur
    Khan, Ehsan Ullah
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2021, 71 (04) : 1093 - 1099
  • [24] The effect of auto-planning parameter settings on the quality of automated cervical cancer plans
    Li, Mengze
    Qiu, Tao
    Jin, Fu
    Luo, Huanli
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2024, 17 (03)
  • [25] Plan complexity metrics for head and neck VMAT competition plans
    Okamoto, Hiroyuki
    Wakita, Akihisa
    Tani, Kensuke
    Kito, Satoshi
    Kurooka, Masahiko
    Kodama, Takumi
    Tohyama, Naoki
    Fujita, Yukio
    Nakamura, Satoshi
    Iijima, Kotaro
    Chiba, Takahito
    Nakayama, Hiroki
    Murata, Miyuki
    Goka, Tomonori
    Igaki, Hiroshi
    MEDICAL DOSIMETRY, 2024, 49 (03) : 244 - 253
  • [26] Improved VMAT planning for head and neck tumors with an advanced optimization algorithm
    Klippel, Norbert
    Sohmuecking, Michael
    Terribilini, Dario
    Geretschlaeger, Andreas
    Aebersold, Daniel M.
    Manser, Peter
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2015, 25 (04): : 333 - 340
  • [27] Integrated multicriterial optimization of beam angles and intensity profiles for coplanar and noncoplanar head and neck IMRT and implications for VMAT
    Voet, Peter W. J.
    Breedveld, Sebastiaan
    Dirkx, Maarten L. P.
    Levendag, Peter C.
    Heijmen, Ben J. M.
    MEDICAL PHYSICS, 2012, 39 (08) : 4858 - 4865
  • [28] A patient-specific auto-planning method for MRI-guided adaptive radiotherapy in prostate cancer
    Liu, Xiaonan
    Chen, Xinyuan
    Chen, Deqi
    Liu, Yuxiang
    Quan, Hong
    Gao, Linrui
    Yan, Lingling
    Dai, Jianrong
    Men, Kuo
    RADIOTHERAPY AND ONCOLOGY, 2024, 200
  • [29] Do a priori expectations of plan quality offset planning variability in head and neck IMRT?
    Alves, N.
    Ventura, T.
    Mateus, J.
    Capela, M.
    Lopes, M. C.
    RADIATION PHYSICS AND CHEMISTRY, 2020, 168
  • [30] Dosimetric analysis of Rapid Arc (VMAT) treatment planning in head and neck cancer for quality assurance treatment
    Amin, Naima
    Atiq, Atia
    Ikram, Muhammad
    Atiq, Maria
    Naeem, Hamza
    Yousaf, Muhammad
    Farooq, Atiqa
    Iqbal, Khalid
    Akbar, Anzal
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2023, 35 (02)