High frame rate speckle tracking algorithm towards a real-time implementation

被引:0
作者
Orlowska, Marta [1 ]
Dallai, Alessandro [2 ]
Tortoli, Piero [2 ]
D'hooge, Jan [1 ]
Ramalli, Alessandro [2 ]
机构
[1] Katholieke Univ Leuven, Dept Cardiovasc Sci, Leuven, Belgium
[2] Univ Florence, Dept Informat Engn, Florence, Italy
来源
2022 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IEEE IUS) | 2022年
关键词
high frame rate; speckle tracking; real-time; motion estimation; ULA-OP; cardiac imaging; STRAIN;
D O I
10.1109/IUS54386.2022.9957337
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
High frame rate speckle tracking echocardiography (HFR STE) assesses clinical biomarkers in a user-friendly manner. Real-time feedback of the estimated motion may improve acquisition quality, speed up examinations, and reduce patient discomfort. However, its implementation is challenging due to the computational load requirements. The aim of this study was to improve the computational efficiency of a previously presented HFR STE algorithm to make feasible its real-time implementation on the ULA-OP 256 research scanner. The axial and lateral motion estimators were adapted to IQ demodulated data, and modified to decrease the computational load. To validate the implementation, apical 4-chamber views were recorded from healthy volunteers and the motion results obtained in real-time were compared offline with those produced by the original approach. In both cases, the same myocardial contour was tracked to extract the velocity, strain, and strain rate curves. The extracted curves had a physiological pattern and together with the clinical biomarkers were not significantly different from those obtained with the original approach.
引用
收藏
页数:4
相关论文
共 17 条
  • [1] Architecture of an Ultrasound System for Continuous Real-Time High Frame Rate Imaging
    Boni, Enrico
    Bassi, Luca
    Dallai, Alessandro
    Meacci, Valentino
    Ramalli, Alessandro
    Scaringella, Monica
    Guidi, Francesco
    Ricci, Stefano
    Tortoli, Piero
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (09) : 1276 - 1284
  • [2] ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods
    Boni, Enrico
    Bassi, Luca
    Dallai, Alessandro
    Guidi, Francesco
    Meacci, Valentino
    Ramalli, Alessandro
    Ricci, Stefano
    Tortoli, Piero
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2016, 63 (10) : 1488 - 1495
  • [3] Practical Guide to Ultrasound Beam Forming: Beam Pattern and Image Reconstruction Analysis
    Demi, Libertario
    [J]. APPLIED SCIENCES-BASEL, 2018, 8 (09):
  • [4] Virtual Real-Time for High PRF Multiline Vector Doppler on ULA-OP 256
    Giangrossi, Claudio
    Meacci, Valentino
    Ricci, Stefano
    Matera, Riccardo
    Boni, Enrico
    Dallai, Alessandro
    Tortoli, Piero
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2021, 68 (03) : 624 - 631
  • [5] Cardiac Strain Imaging With Coherent Compounding of Diverging Waves
    Grondin, Julien
    Sayseng, Vincent
    Konofagou, Elisa E.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2017, 64 (08) : 1212 - 1222
  • [6] High-Frame-Rate Speckle-Tracking Echocardiography
    Joos, Philippe
    Poree, Jonathan
    Liebgott, Herve
    Vray, Didier
    Baudet, Mathilde
    Faurie, Julia
    Tournoux, Francois
    Cloutier, Guy
    Nicolas, Barbara
    Garcia, Damien
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2018, 65 (05) : 720 - 728
  • [7] Importance of Left Ventricular Longitudinal Function and Functional Reserve in Patients With Degenerative Mitral Regurgitation: Assessment by Two-Dimensional Speckle Tracking
    Lancellotti, Patrizio
    Cosyns, Bernard
    Zacharakis, Dimitris
    Attena, Emilio
    Van Camp, Guy
    Gach, Olivier
    Radermecker, Marc
    Pierard, Luc A.
    [J]. JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2008, 21 (12) : 1331 - 1336
  • [8] Usefulness of two-dimensional speckle strain for evaluation of left ventricular diastolic deformation in patients with coronary artery disease
    Liang, Hsin-Yueh
    Cauduro, Sanderson
    Pellikka, Patricia
    Wang, Jianwen
    Urheim, Stig
    Yang, Eric H.
    Rihal, Chiranjit
    Belohlavek, Marek
    Khandheria, Bijoy
    Miller, Fletcher A.
    Abraham, Theodore P.
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2006, 98 (12) : 1581 - 1586
  • [9] A Fast Normalized Cross-Correlation Calculation Method for Motion Estimation
    Luo, Jianwen
    Konofagou, Elisa E.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2010, 57 (06) : 1347 - 1357
  • [10] Usefulness of left atrial speckle tracking echocardiography in predicting recurrence of atrial fibrillation after radiofrequency ablation: a systematic review and meta-analysis
    Nielsen, Anne Bjerg
    Skaarup, Kristoffer Grundtvig
    Lassen, Mats Christian Hojbjerg
    Djernaes, Kasper
    Hansen, Morten Lock
    Svendsen, Jesper Hastrup
    Johannessen, Arne
    Hansen, Jim
    Sorensen, Samuel Kiil
    Gislason, Gunnar
    Biering-Sorensen, Tor
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2020, 36 (07) : 1293 - 1309