Fault diagnosis;
instantaneous active power (IAP);
instantaneous reactive power (IRP);
inter-turn short-circuit faults;
open-circuit faults;
signature analysis;
squirrel cage induction motor drives;
stator faults;
voltage supply unbalance;
TURN SHORT CIRCUITS;
AIR-GAP TORQUE;
INTERTURN FAULTS;
ONLINE DIAGNOSIS;
WINDING FAULTS;
BROKEN-BAR;
MACHINES;
INSULATION;
LOCATION;
D O I:
10.1109/TII.2014.2307013
中图分类号:
TP [自动化技术、计算机技术];
学科分类号:
0812 ;
摘要:
In this paper, the instantaneous active and reactive power signature analyses are presented for stator fault diagnosis in operating squirrel cage three-phase induction motors either directly connected to the mains or fed from inverters. Both simulation and experimental results are presented to show the effectiveness and the merits of the proposed approach that offers the possibility to detect this type of fault and to discriminate it from other abnormality conditions responsible for the same motor behavior by comparing the signature analyses of the two considered quantities.