Effects of scleral-lens oxygen transmissibility on corneal thickness: A pilot study

被引:20
作者
Tan, Bo [1 ]
Tse, Vivien [1 ]
Kim, Young Hyun [1 ,2 ,3 ]
Lin, Kristina [1 ]
Zhou, Yixiu [1 ]
Lin, Meng C. [1 ,2 ]
机构
[1] Univ Calif Berkeley, Clin Res Ctr, Sch Optometry, Berkeley, CA 94720 USA
[2] Univ Calif Berkeley, Vis Sci Grad Program, Berkeley, CA 94720 USA
[3] Univ Calif Berkeley, Chem & Biomol Engn Dept, Berkeley, CA 94720 USA
关键词
Scleral lens; Oxygen transmissibility; Corneal edema; OCT; OPTICAL COHERENCE TOMOGRAPHY; OCULAR SURFACE; DISTORTIONS; METABOLISM;
D O I
10.1016/j.clae.2019.04.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate the effect of various oxygen transmissibilities (Dk/t) of scleral lenses and corneal thickness recovery time from overnight eye closure with patching on corneal edema during 5 h lens wear. Methods: Scleral lenses (hofocon A, 15.6 mm diameter) were worn bilaterally with three different Dks (100, 140, and 160 Barrer). Central and peripheral corneal thickness (CCT and PCT) were measured using optical coherence tomography. Four subjects were randomly selected for one additional visit and asked to patch one eye before night sleeping. The patch was not removed until lens insertion to avoid corneal deswelling. Then CCT of both eyes was measured. Results: Ten neophytes with healthy eyes participated in the study. Mean [95% CI] Dk/t of the study lenses was 32.0 [29.2, 34.7] hBarrer/cm. Mean [95% CI] CCT immediately upon lens insertion and after 5 h of lens wear were 532.4 [520.3, 544.5] mu m and 538.7 [526.5, 551.0] mu m, respectively. Mean [95% CI] percentage change (%Delta) in CCT was 1.2% [0.9%, 1.5%], 1.2% [0.9%, 1.4%], and 0.8% [0.6%, 1.1%] for CCT, nasal PCT, and temporal PCT, respectively. There was an inverse relationship between temporal Dk/t and %Delta PCT (p < 0.05) while Dk/t was not found significantly associated with either CCT or nasal PCT. The patched eyes maintained a relatively stable CCT and showed progressive deswelling, starting and ending with 2.8% and 0.6%, respectively. In contrast, the unpatched eyes swelled, starting with nearly 0% and ending with 0.7% with a maximum swelling of 1.8%. Conclusion: There was limited amount of corneal edema induced by short-term scleral lens wear with lens Dk/t ranging from 21 to 47 hBarrer/cm and lenses with lower lens Dk/t did not induce significantly higher corneal swelling. Scleral lens insertion soon after overnight eye closure with patching did not introduce additional swelling for young and healthy eyes.
引用
收藏
页码:366 / 372
页数:7
相关论文
共 24 条
  • [1] Central Corneal Edema with Scleral-Lens Wear
    Kim, Young Hyun
    Tan, Bo
    Lin, Meng C.
    Radke, Clayton J.
    CURRENT EYE RESEARCH, 2018, 43 (11) : 1305 - 1315
  • [2] Scleral Lens Thickness and Corneal Edema Under Closed Eye Conditions
    Fisher, Damien
    Collins, Michael J.
    Vincent, Stephen J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (05): : 194 - 199
  • [3] Scleral Lens Thickness and Corneal Edema Under Open Eye Conditions
    Fisher, Damien
    Collins, Michael J.
    Vincent, Stephen J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2022, 48 (05): : 200 - 205
  • [4] The effect of different thickness scleral lens on corneal parameters in eyes with keratoconus
    Iqbal, Asif
    Thomas, Rinu
    Mahadevan, Rajeswari
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (12) : 4251 - 4256
  • [5] Importance of contact lens power and thickness in oxygen transmissibility
    Lira, Madalena
    Pereira, Clara
    Elisabete, M.
    Real Oliveira, C. D.
    Castanheira, Elisabete M. S.
    CONTACT LENS & ANTERIOR EYE, 2015, 38 (02) : 120 - 126
  • [6] Critical Contact Lens Oxygen Transmissibility and Tear Lens Oxygen Tension to Preclude Corneal Neovascularization
    Yeung, Karen K.
    Yang, Helen J.
    Nguyen, Andrew L.
    Weissman, Barry A.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S291 - S295
  • [7] Fluid reservoir thickness and corneal oedema during closed eye scleral lens wear
    Fisher, Damien
    Collins, Michael J.
    Vincent, Stephen J.
    CONTACT LENS & ANTERIOR EYE, 2021, 44 (01) : 102 - 107
  • [8] Changes in the corneal thickness and limbus after 1 year of scleral contact lens use
    de Luis Eguileor, Beatriz
    Acera, Arantxa
    Santamaria Carro, Alaitz
    Feijoo Lera, Raquel
    Escudero Argaluza, Julene
    Etxebarria Ecenarro, Jaime
    EYE, 2020, 34 (09) : 1654 - 1661
  • [9] Corneal refractive therapy with different lens materials, Part 2: Effect of oxygen transmissibility on corneal shape and optical characteristics
    Lu, Fenghe
    Simpson, Trefford
    Sorbara, Luigina
    Fonn, Desmond
    OPTOMETRY AND VISION SCIENCE, 2007, 84 (04) : 349 - 356
  • [10] Influence of Apical Clearance on Mini-Scleral Lens Settling, Clinical Performance, and Corneal Thickness Changes
    Esen, Fehim
    Toker, Ebru
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (04): : 230 - 235