Ultratrace determination of Pb, Se and As in wine samples by electrothermal vaporization inductively coupled plasma mass spectrometry

被引:32
作者
Grindlay, Guillermo [1 ]
Mora, Juan [1 ]
Gras, Luis [1 ]
de Loos-Vollebregt, M. T. C. [2 ]
机构
[1] Univ Alicante, Dept Analyt Chem Nutr & Food Sci, E-03080 Alicante, Spain
[2] Delft Univ Technol, Fac Sci Appl, NL-2628 BC Delft, Netherlands
关键词
Electrothermal vaporization inductively coupled plasma mass spectrometry; As; Pb; Se; Wine; PERFORMANCE LIQUID-CHROMATOGRAPHY; OPTICAL-EMISSION SPECTROMETRY; INTERNAL STANDARDIZATION; MULTIELEMENT ANALYSIS; TRACE-ELEMENTS; ORGANIC-ACIDS; LEAD; CLASSIFICATION; INTERFERENCES; ENHANCEMENT;
D O I
10.1016/j.aca.2009.05.020
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of Pb, Se and As in wine has a great interest due to health risks and legal requirements. To perform the analysis of wine, two considerations must be taken into account: (i) the low concentration level of the analytes: and (ii) the risk of interferences due to wine matrix components. The goal of this work is to evaluate electrothermal vaporization (ETV) sample introduction for ultratrace determination of Pb, Se and As in wine samples by inductively coupled plasma mass spectrometry (ICP-MS). The results obtained with ETV-ICP-MS were compared to those obtained with conventional liquid sample introduction in ICP-MS and electrothermal atomic absorption spectrometry (ETAAS). Analytical figures of merit of ETV sample introduction strongly depend on the amount of wine sample, on the modifier nature (i.e. Pd, ascorbic acid or citric acid) and concentration and on the temperature program. Wine matrix components exert a great influence on analyte transport efficiency. Due to this fact. the analysis of wine cannot be performed by means of external calibration but the standard addition methodology should be used. The determination of Pb and Se in wine by ETV-ICP-MS provides similar results as conventional liquid sample introduction ICP-MS. For As, the concentration values obtained with ETV sample introduction were between two and four times lower than with the conventional system. These differences are related to the lower intensity of polyatomic interferences (i.e. (ArCl+)-Ar-40-Cl-35 vs. As-75(+)) obtained for ETV sample introduction when compared to the conventional system. Finally, no differences for Pb determination were observed between ETV sample introduction and ETAAS. Unfortunately, the limits of detection for As and Se in ETAAS were not low enough to quantify these elements in the wine samples tested. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:154 / 160
页数:7
相关论文
共 39 条
  • [1] SIGNAL ENHANCEMENT OF ELEMENTS DUE TO THE PRESENCE OF CARBON-CONTAINING COMPOUNDS IN INDUCTIVELY COUPLED PLASMA MASS-SPECTROMETRY
    ALLAIN, P
    JAUNAULT, L
    MAURAS, Y
    MERMET, JM
    DELAPORTE, T
    [J]. ANALYTICAL CHEMISTRY, 1991, 63 (14) : 1497 - 1498
  • [2] ICP-MS multi-element analysis of wine samples - a comparative study of the methodologies used in two laboratories
    Almeida, CMR
    Vasconcelos, MTSD
    Barbaste, M
    Medina, B
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2002, 374 (02) : 314 - 322
  • [3] Study of mineral profile of Montilla-Moriles "fino" wines using inductively coupled plasma atomic emission spectrometry methods
    Alvarez, Mercedes
    Moreno, Isabel M.
    Jos, Angeles M.
    Camean, Ana M.
    Gonzalez, A. Gustavo
    [J]. JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2007, 20 (05) : 391 - 395
  • [4] Determination of rare earth elements in wine by inductively coupled plasma mass spectrometry using a microconcentric nebulizer
    Augagneur, S
    Medina, B
    Szpunar, J
    Lobinski, R
    [J]. JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (09) : 713 - 721
  • [5] Analysis of arsenic, lead and cadmium in wines from the Canary Islands, Spain, by ICP/MS
    Barbaste, M
    Medina, B
    Perez-Trujillo, JP
    [J]. FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2003, 20 (02): : 141 - 148
  • [6] Direct solid sampling with electrothermal vaporization/atomization: what for and how?
    Belarra, MA
    Resano, M
    Vanhaecke, F
    Moens, L
    [J]. TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2002, 21 (12) : 828 - 839
  • [7] Ascorbic acid-induced browning of (+)-catechin in a model wine system
    Bradshaw, MP
    Prenzler, PD
    Scollary, GR
    [J]. JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2001, 49 (02) : 934 - 939
  • [8] Development of a procedure for the multi-element determination of trace elements in wine by ICP-MS
    Castiñeira, MM
    Brandt, R
    von Bohlen, A
    Jakubowski, N
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 2001, 370 (05) : 553 - 558
  • [9] Measurements of contaminant elements of wines by inductively coupled plasma-mass spectrometry: A comparison of two calibration approaches
    Catarino, Sofia
    Curvelo-Garcia, A. S.
    de Sousa, R. Bruno
    [J]. TALANTA, 2006, 70 (05) : 1073 - 1080
  • [10] Method development for the determination of lead in wine using electrothermal atomic absorption spectrometry comparing platform and filter furnace atomizers and different chemical modifiers
    Dessuy, Morgana B.
    Vale, Maria Goreti R.
    Souza, Anderson S.
    Ferreira, Sergio L. C.
    Welz, Bernhard
    Katskov, Dmitri A.
    [J]. TALANTA, 2008, 74 (05) : 1321 - 1329