Cuff size influences blood pressure measurement in obese children and adolescents

被引:0
|
作者
Muhamed, Parosh Kadir [1 ]
Olsen, Michael Hecht [2 ]
Holm, Jens-Christian [3 ,4 ]
Ibsen, Hans [5 ]
Hvidt, Kristian Nebelin [3 ,6 ]
机构
[1] Holbaek Cent Hosp, Dept Med, Holbaek, Denmark
[2] Odense Univ Hosp, Cardiovasc & Metab Prevent Clin, Dept Endocrinol, Endocrinol Ctr Individualised Med Arterial Dis CI, Odense, Denmark
[3] North West Univ, HART, Sch Physiol Nutr & Consumer Sci, Mahikeng, South Africa
[4] Holbaek Cent Hosp, Dept Paediat, Childrens Obes Clin, Holbaek, Denmark
[5] Holbaek Cent Hosp, Dept Med, Div Cardiol, Holbaek, Denmark
[6] Kokkedal Laegectr, Copenhagen, Denmark
来源
DANISH MEDICAL JOURNAL | 2016年 / 63卷 / 01期
关键词
HEALTH;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Recently, we established that a group of obese children and adolescents had a higher blood pressure (BP) than a healthy control group. In the present study, we investigate whether the higher BP in the obese group was influenced by BP cuff sizes. Methods: A total of 104 obese patients aged 10-18 years were compared with 50 controls. BP was measured with a validated oscillometric device using an appropriate cuff size depending on each person's arm circumferences (AC) according to the manufacturer's recommendation; small (AC < 23 cm), medium (23 <= AC <= 32 cm) and large (AC >= 32 cm). Results: Cuff sizes had a significant impact on BP measurements. Despite the influence of cuff size, multiple regression analyses revealed that systolic BP was 6.8 mmHg higher and diastolic BP 3.2 mmHg higher in the obese group than in the control group. A step function, i.e. a sudden fall in BP, was seen at the point of switching from small to medium cuff size in the control group, which suggests that systolic BP was overestimated when using small cuff size and underestimated when using medium cuff size in subjects with an AC near 23 cm. Conclusions: BP was higher in the obese group than in the control group although BP was influenced by BP cuff sizes.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] BLOOD PRESSURE MEASUREMENT: ARM CIRCUMFERENCE AND CUFF SIZE AVAILABILITY
    Veiga, Eugenia Velludo
    Moura Arcuri, Edna Aparecida
    Cloutier, Lyne
    Ferreira Santos, Jair Licio
    REVISTA LATINO-AMERICANA DE ENFERMAGEM, 2009, 17 (04): : 455 - 461
  • [22] SPHYGMOMANOMETER CUFF SIZE + ACCURACY OF INDIRECT MEASUREMENT OF BLOOD PRESSURE
    KARVONEN, MJ
    TELIVUO, LJ
    JARVINEN, EJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1964, 13 (05): : 688 - &
  • [23] Blood pressure and arterial stiffness in obese children and adolescents
    Hvidt, Kristian Nebelin
    DANISH MEDICAL JOURNAL, 2015, 62 (03):
  • [24] THE OPTIMUM SIZE CUFF FOR AUSCULTATORY BLOOD PRESSURE MEASUREMENTS IN CHILDREN
    MOSS, AJ
    ADAMS, FH
    DIXON, WJ
    HUGGINS, M
    AMERICAN JOURNAL OF DISEASES OF CHILDREN, 1960, 100 (04): : 617 - 617
  • [25] CUFF BLADDER SIZE IN A BLOOD-PRESSURE SURVEY OF CHILDREN
    VOORS, AW
    AMERICAN JOURNAL OF EPIDEMIOLOGY, 1975, 101 (06) : 489 - 494
  • [26] MEASUREMENT OF BLOOD-PRESSURE IN CHILDREN AND ADOLESCENTS
    STORR, A
    OFFENTLICHE GESUNDHEITSWESEN, 1980, 42 (12): : 979 - 980
  • [27] Challenges in blood pressure measurement in children with obesity: focus on the cuff
    Evripidou, Kleo
    Chainoglou, Athanasia
    Kotsis, Vasilios
    Stabouli, Stella
    PEDIATRIC NEPHROLOGY, 2025,
  • [28] Measurement of blood pressure in children: Recommendations and perceptions on cuff selection
    Arafat, M
    Mattoo, TK
    PEDIATRICS, 1999, 104 (03)
  • [29] EFFECT OF SIZE OF CUFF BLADDER ON ACCURACY OF MEASUREMENT OF INDIRECT BLOOD PRESSURE
    SIMPSON, JA
    JAMIESON, G
    DICKHAUS, DW
    GROVER, RF
    AMERICAN HEART JOURNAL, 1965, 70 (02) : 208 - &
  • [30] Measurement of blood pressure in hospitals: Is the use of a standard cuff size adequate?
    Comparsi, A
    da Costa, BP
    Antonello, I
    Ogando, P
    de Souza, LH
    de Figueiredo, CP
    JOURNAL OF HYPERTENSION, 2004, 22 : S188 - S189