Characterization of a low frequency magnetic noise from a two-stage pulse tube cryocooler

被引:4
作者
Eshraghi, M. J. [1 ]
Sasada, I. [1 ]
Kim, J. M. [2 ]
Lee, Y. H. [2 ]
机构
[1] Kyushu Univ, Dept Appl Sci Elect & Mat, Kasuga, Fukuoka 8168580, Japan
[2] Korea Res Inst Stand & Sci, Ctr Brain & Cognit Sci Res, Taejon 305340, South Korea
关键词
Pulse tube; Magnetic measurements; Magnetic shielding; Regenerators; SQUIDs; INTERMETALLIC COMPOUNDS; COOLER;
D O I
10.1016/j.cryogenics.2009.03.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
Magnetic noise of a two-stage pulse tube cryocooler (PT) was measured by a fundamental mode orthogonal fluxgate magnetometer and by a LTS Double Relaxation Oscillation SQUID (DROS) first-order planar gradiometer. The magnetometer was installed in a dewar made of aluminum at 12 cm distance from a section containing magnetic regenerative materials of the second pulse tube. The magnetic noise spectrum showed a clear peak at 1.8 Hz, which is the fundamental frequency of the He gas pumping rate. The 1.8 Hz magnetic noise registered a peak, during the cooling down process, when the second cold-stage temperature was around 12 K, which is well correlated with the 1.8 Hz variation of the temperature of the second cold stage. Hence, we attributed the main source of this magnetic noise to the temperature variation of the magnetic moments resulting from magnetic regenerative materials, Er(3)Ni and HoCu(2), in the presence of background static magnetic fields. We have also pointed out that the superconducting magnetic shield of lead sheets reduced the low frequency magnetic noise generated from the magnetic regenerative materials. With this arrangement, the magnetic noise amplitude measured with the LTS DROS gradiometer, mounted at 7 cm horizontal distance from the magnetic regenerative materials, in the optimum condition, was lower than 500 pT peak-to-peak, whereas the noise level without lead shielding was higher than the dynamic range of DROS instrumentations which was around +/- 10 nT. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:334 / 339
页数:6
相关论文
共 15 条
  • [1] Interference characterisation of a commercial Joule-Thomson cooler to be used in a SQUID-based foetal heart monitor
    Bangma, MR
    Rijpma, AP
    de Vries, E
    Reincke, HA
    Holland, HJ
    ter Brake, HJM
    Rogalla, H
    [J]. CRYOGENICS, 2001, 41 (09) : 657 - 663
  • [2] Thermodynamical aspects of pulse tubes II
    de Waele, ATAM
    Steijaert, PP
    Koning, JJ
    [J]. CRYOGENICS, 1998, 38 (03) : 329 - 335
  • [3] ESHRAGHI MJ, 2009, IEEE T MAG IN PRESS
  • [4] COOLING OF SQUIDS USING A GIFFORD-MCMAHON CRYOCOOLER CONTAINING MAGNETIC REGENERATIVE MATERIAL TO MEASURE BIOMAGNETISM
    FUJIMOTO, S
    KAZAMI, K
    TAKADA, Y
    YOSHIDA, T
    OGATA, H
    KADO, H
    [J]. CRYOGENICS, 1995, 35 (02) : 143 - 148
  • [5] MAGNETIC-PROPERTIES OF RARE-EARTH COPPER INTERMETALLIC COMPOUNDS, RCU2 .2. LIGHT RARE-EARTH
    HASHIMOTO, Y
    FUJII, H
    FUJIWARA, H
    OKAMOTO, T
    [J]. JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1979, 47 (01) : 73 - 76
  • [6] HOHMANN R, 1999, IEEE T APPL SUPERCON, V9
  • [7] A DRUNG-TYPE MAGNETOMETER MOUNTED ON A GM CRYOCOOLER
    KAZAMI, K
    TAKADA, Y
    FUJIMOTO, S
    YOSHIDA, T
    OGATA, H
    KADO, H
    [J]. SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1994, 7 (05) : 256 - 259
  • [8] Double relaxation oscillation SQUID systems for biomagnetic multichannel measurements
    Lee, YH
    Kwon, H
    Kim, JM
    Kim, K
    Kim, IS
    Park, YK
    [J]. IEICE TRANSACTIONS ON ELECTRONICS, 2005, E88C (02): : 168 - 174
  • [9] A single-stage pulse tube cooler reached 12.6 K
    Qiu, LM
    He, YL
    Gan, ZH
    Chen, GB
    [J]. CRYOGENICS, 2005, 45 (09) : 641 - 643
  • [10] Sasada I., 2006, J APPL PHYS, V99