Early results using a biodegradable magnesium screw for modified chevron osteotomies

被引:95
作者
Plaass, Christian [1 ]
Ettinger, Sarah [1 ]
Sonnow, Lena [2 ]
Koenneker, Soeren [3 ]
Noll, Yvonne [1 ]
Weizbauer, Andreas [4 ,5 ]
Reifenrath, Janin [4 ,5 ]
Claassen, Leif [1 ]
Daniilidis, Kiriakos [1 ]
Stukenborg-Colsman, Christina [1 ]
Windhagen, Henning [1 ]
机构
[1] Hannover Med Sch, Dept Orthoped Surg, Anna von Borries Str 1-7, D-30625 Hannover, Germany
[2] Hannover Med Sch, Inst Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[3] Hannover Med Sch, Dept Plast Aesthet Hand & Reconstruct Surg, Carl Neuberg Str 1, D-30625 Hannover, Germany
[4] Hannover Med Sch, Dept Orthoped Surg, Lab Biomech & Biomat, Anna von Borries Str 1-7, Hannover, Germany
[5] Hannover Med Sch, Dept Orthoped Surg, Ctr Biocompatibil & Implant Immunol, CrossBIT, Carl Neuberg Str 1-7, D-30625 Hannover, Germany
关键词
hallux valgus; magnesium; biodegradable implant; Chevron; HALLUX-VALGUS; IN-VIVO; CRANIOFACIAL SURGERY; BIOABSORBABLE PINS; RABBIT MODEL; FIXATION; TITANIUM; REMOVAL; TISSUE; PLATES;
D O I
10.1002/jor.23241
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
This is the first larger study analyzing the use of magnesium-based screws for fixation of modified Chevron osteotomies in hallux valgus surgery. Forty-four patients (45 feet) were included in this prospective study. A modified Chevron osteotomy was performed on every patient and a magnesium screw used for fixation. The mean clinical follow up was 21.4 weeks. The mean age of the patients was 45.5 years. Forty patients could be provided with the implant, in four patients the surgeon decided to change to a standard metallic implant. The AOFAS, FAAM and pain NRS-scale improved markedly. The hallux valgus angle, intermetatarsal angle and sesamoid position improved significantly. Seven patients showed dorsal subluxation, rotation or medial shifting of the metatarsal heads within the first 3 months. One of these patients was revised, in all others the findings were considered clinically not significant or the patients refused revision. This study shows the feasibility of using magnesium screws in hallux valgus-surgery. Surgeons starting with the use of these implants should be aware of the proper handling of these implants and should know about corrosion effects during healing and its radiographic appearance. (c) 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:2207-2214, 2016.
引用
收藏
页码:2207 / 2214
页数:8
相关论文
共 52 条
  • [1] Removal of asymptomatic bone plates used for orthognathic surgery and facial fractures
    Alpert, B
    Seligson, D
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1996, 54 (05) : 618 - 621
  • [2] Screw Versus Plate Fixation for Chevron Osteotomy: A Retrospective Study
    Andrews, Boyd J.
    Fallat, Lawrence M.
    Kish, John P.
    [J]. JOURNAL OF FOOT & ANKLE SURGERY, 2016, 55 (01) : 81 - 84
  • [3] AUSTIN DW, 1981, CLIN ORTHOP RELAT R, P25
  • [4] Böstman OM, 2000, CLIN ORTHOP RELAT R, P216
  • [5] Dynamic cervical plates - Biomechanical evaluation of load sharing and stiffness
    Brodke, DS
    Gollogly, S
    Mohr, RA
    Nguyen, BK
    Dailey, AT
    Bachus, KN
    [J]. SPINE, 2001, 26 (12) : 1324 - 1329
  • [6] Hardware removal: Indications and expectations
    Busam, ML
    Esther, RJ
    Obremskey, WT
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2006, 14 (02) : 113 - 120
  • [7] Fracture Healing Using Degradable Magnesium Fixation Plates and Screws
    Chaya, Amy
    Yoshizawa, Sayuri
    Verdelis, Kostas
    Noorani, Sabrina
    Costello, Bernard J.
    Sfeir, Charles
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (02) : 295 - 305
  • [8] CLANCY J T, 1989, Journal of Foot Surgery, V28, P284
  • [9] AUSTIN BUNIONECTOMY WITH 3M STAPLIZER FIXATION - AN ASSESSMENT OF 20 CASES
    DEFRONZO, DJ
    LANDSMAN, AR
    LANDSMAN, AS
    STERN, SF
    [J]. JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 1991, 81 (03): : 140 - 149
  • [10] Single absorbable polydioxanone pin fixation for distal chevron bunion osteotomies
    DeOrio, JK
    Ware, AW
    [J]. FOOT & ANKLE INTERNATIONAL, 2001, 22 (10) : 832 - 835