Determinants of pulmonary perfusion measured by electrical impedance tomography

被引:43
|
作者
Smit, HJ
Noordegraaf, AV
Marcus, JT
Boonstra, A
de Vries, PM
Postmus, PE
机构
[1] Vrije Univ Amsterdam Med Ctr, Dept Pulm Med, NL-1007 MB Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Phys & Med Technol, NL-1007 MB Amsterdam, Netherlands
关键词
heart failure; stroke volume; lung blood vessel; chronic obstructive pulmonary disease;
D O I
10.1007/s00421-004-1043-3
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Electrical impedance tomography (EIT) is a non-invasive imaging technique for detecting blood volume changes that can visualize pulmonary perfusion. The two studies reported here tested the hypothesis that the size of the pulmonary microvascular bed, rather than stroke volume (SV), determines the EIT signal. In the first study, the impedance changes relating to the maximal pulmonary pulsatile blood volume during systole (DeltaZ(sys)) were measured in ten healthy subjects, ten patients diagnosed with chronic obstructive pulmonary disease, who were considered to have a reduced pulmonary vascular bed, and ten heart failure patients with an assumed low cardiac output but with a normal lung parenchyma. Mean DeltaZ(sys) (SD) in these groups was 261 (34)x10(-5), 196 (39)x10(-5) (P<0.001) and 233 (61)x10(-5) arbitrary units (AU) (P=NS), respectively. In the second study, including seven healthy volunteers, DeltaZ(sys) was measured at rest and during exercise on a recumbent bicycle while SV was measured by means of magnetic resonance imaging. The DeltaZ(sys) at rest was 352 (53)x10(-5) and 345 (112)x10(-5) AU during exercise (P=NS), whereas SV increased from 83 (21) to 105 (34) ml (P<0.05). The EIT signal likely reflects the size of the pulmonary microvascular bed, since neither a low cardiac output nor a change in SV of the heart appear to influence EIT.
引用
收藏
页码:45 / 49
页数:5
相关论文
共 50 条
  • [1] Determinants of pulmonary perfusion measured by electrical impedance tomography
    Henk J. Smit
    Anton Vonk Noordegraaf
    J. Tim Marcus
    Anco Boonstra
    Peter M. de Vries
    Pieter E. Postmus
    European Journal of Applied Physiology, 2004, 92 : 45 - 49
  • [2] Pulmonary perfusion measured by means of electrical impedance tomography
    Noordegraaf, AV
    Kunst, PWA
    Janse, A
    Marcus, JT
    Postmus, PE
    Faes, TJC
    de Vries, PMJM
    PHYSIOLOGICAL MEASUREMENT, 1998, 19 (02) : 263 - 273
  • [3] Pulmonary perfusion measured by means of electrical impedance tomography
    Department of Pulmonary Medicine, Vrije Universiteit, Academic Hospital, Amsterdam, Netherlands
    不详
    不详
    Physiol. Meas., 2 (263-273):
  • [4] Electrical Impedance Tomography in the pulmonary perfusion tests
    Nita, Konrad
    Matacz, Marcin
    Filipowicz, Stefan F.
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (12B): : 141 - 143
  • [5] A review on electrical impedance tomography for pulmonary perfusion imaging
    Nguyen, D. T.
    Jin, C.
    Thiagalingam, A.
    McEwan, A. L.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (05) : 695 - 706
  • [6] Research progress on electrical impedance tomography in pulmonary perfusion
    She L.
    Zhou R.
    Pan P.
    Li Z.
    Liu J.
    Xie F.
    Shengwu Yixue Gongchengxue Zazhi/Journal of Biomedical Engineering, 2023, 40 (06): : 1249 - 1254
  • [7] Unmatched ventilation and perfusion measured by electrical impedance tomography predicts the outcome of ARDS
    Elena Spinelli
    Michael Kircher
    Birgit Stender
    Irene Ottaviani
    Maria C. Basile
    Ines Marongiu
    Giulia Colussi
    Giacomo Grasselli
    Antonio Pesenti
    Tommaso Mauri
    Critical Care, 25
  • [8] Electrical Impedance Tomography: Is It Ready to Measure Pulmonary Perfusion Distribution at the Bedside?
    Putensen, Christian
    Gattinoni, Luciano
    Leonhardt, Steffen
    ANESTHESIOLOGY, 2023, 139 (06) : 722 - 725
  • [9] Unmatched ventilation and perfusion measured by electrical impedance tomography predicts the outcome of ARDS
    Spinelli, Elena
    Kircher, Michael
    Stender, Birgit
    Ottaviani, Irene
    Basile, Maria C.
    Marongiu, Ines
    Colussi, Giulia
    Grasselli, Giacomo
    Pesenti, Antonio
    Mauri, Tommaso
    CRITICAL CARE, 2021, 25 (01)
  • [10] ELECTRICAL-IMPEDANCE TOMOGRAPHY DURING PULMONARY VENTILATION AND PERFUSION IN MAN
    HOLDER, DS
    TEMPLE, AJ
    JOURNAL OF PHYSIOLOGY-LONDON, 1992, 446 : P479 - P479