Continuous Arterial Pressure Waveform Analysis Accurately Detects Cardiac Output in Cardiac Surgery: A Prospective Comparison with Thermodilution, Echocardiography, and Magnetic Resonance Techniques

被引:5
作者
Senay, Sahin [1 ]
Toraman, Fevzi [2 ]
Gelmez, Serkan [3 ]
Dagdelen, Sinan [4 ]
Karabulut, Hasan [1 ]
Alhan, Cem [1 ]
机构
[1] Acibadem Univ, Sch Med, Acibadem Kadikoy Hosp, Dept Cardiovasc Surg, Istanbul, Turkey
[2] Acibadem Univ, Sch Med, Acibadem Kadikoy Hosp, Dept Anesthesiol, Istanbul, Turkey
[3] Acibadem Univ, Sch Med, Acibadem Kadikoy Hosp, Dept Radiol, Istanbul, Turkey
[4] Acibadem Univ, Sch Med, Acibadem Kadikoy Hosp, Dept Cardiol, Istanbul, Turkey
关键词
PULSE CONTOUR ANALYSIS; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DOPPLER; SYSTEM;
D O I
10.1532/HSF98.20081142
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to compare the accuracy of cardiac output (CO) measurements of noninvasive continuous arterial pressure waveform analysis, thermodilution technique and echocardiography with magnetic resonance (MRI) imaging. Methods: Eleven patients who underwent coronary bypass surgery under cardiopulmonary bypass were prospectively enrolled in this study in 2008. Repeated arterial pressure based, thermodilution, echocardiography, and MRI cardiac output measurements were performed at the postoperative 24th hour. Results: Mean CO values were 5.58 +/- 0.98, 5.97 +/- 0.8, 5.31 +/- 0.52, and 5.32 +/- 0.92 measured with MRI, echocardiography, arterial pressure waveform analysis, and thermodilution techniques, respectively. Bland-Altman analysis showed good overall agreement between the MRI vs arterial waveform analysis and MRI vs thermodilution; values for bias +/- SD were -0.27 +/- 1.06 (95% confidence interval [CI] [-2.3 to 1.8]; P = .42) and -0.26 +/- 0.89 (95% CI [-2.0 to 1.5]; P = .34), respectively. Poor agreement was defined between MRI and echocardiography: bias +/- SD, 0.39 +/- 1.28 (95% CI [-2.1 to 2.9]; P = .34). Conclusions: Arterial pressure - based and thermodilution CO measurement systems yielded results comparable to those obtained with cardiac MRI assessment after cardiac surgery. Arterial pressure wave- form analysis systems for CO measurement may be feasible, noninvasive methods for use in cardiac surgery.
引用
收藏
页码:E75 / E78
页数:4
相关论文
共 17 条
  • [1] Comparison of esophageal Doppler, pulse contour analysis, and real-time pulmonary artery thermodilution for the continuous measurement of cardiac output
    Bein, B
    Worthmann, F
    Tonner, PH
    Paris, A
    Steinfath, M
    Hedderich, J
    Scholz, J
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2004, 18 (02) : 185 - 189
  • [2] Transoesophageal echocardiography is unreliable for cardiac output assessment after cardiac surgery compared with thermodilution
    Bettex, DA
    Hinselmann, V
    Hellermann, JP
    Jenni, R
    Schmid, ER
    [J]. ANAESTHESIA, 2004, 59 (12) : 1184 - 1192
  • [3] MAGNETIC-RESONANCE-IMAGING COMPARED TO ECHOCARDIOGRAPHY TO ASSESS LEFT-VENTRICULAR MASS IN THE HYPERTENSIVE PATIENT
    BOTTINI, PB
    CARR, AA
    PRISANT, LM
    FLICKINGER, FW
    ALLISON, JD
    GOTTDIENER, JS
    [J]. AMERICAN JOURNAL OF HYPERTENSION, 1995, 8 (03) : 221 - 228
  • [4] Cardiac output measured by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery
    Breukers, Rose-Marieke B. G. E.
    Sepehrkhouy, Shahrzad
    Spiegelenberg, Stefan R.
    Groeneveld, A. B. Johan
    [J]. JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2007, 21 (05) : 632 - 635
  • [5] Clinical evaluation of the FloTrac/Nigileo™ system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery
    Button, D.
    Weibel, L.
    Reuthebuch, O.
    Genoni, M.
    Zollinger, A.
    Hofer, C. K.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2007, 99 (03) : 329 - 336
  • [6] CASTILLO E, 2003, RADIOGRAPHICS, V23
  • [7] Performance of a minimally invasive uncalibrated cardiac output monitoring system (Flotrac™/Vigileo™) in haemodynamically unstable patients
    Compton, F. D.
    Zukunft, B.
    Hoffmann, C.
    Zidek, W.
    Schaefer, J. -H.
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2008, 100 (04) : 451 - 456
  • [8] Cardiac output monitoring by pressure recording analytical method in cardiac surgery
    Giomarelli, P
    Biagioli, B
    Scolletta, S
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2004, 26 (03) : 515 - 520
  • [9] A new non-invasive continuous cardiac output trend solely utilizing routine cardiovascular monitors: Comparison with the continuous thermodilution method early cardiovascular monitors
    Ishihara H.
    Okawa H.
    Tanabe K.
    Tsubo T.
    Sugo Y.
    Akiyama T.
    Takeda S.
    [J]. Journal of Clinical Monitoring and Computing, 2004, 18 (5-6) : 313 - 320
  • [10] Continuous cardiac output measurement: arterial pressure analysis versus thermodilution technique during cardiac surgery with cardiopulmonary bypass
    Lorsomradee, S.
    Lorsomradee, S. R.
    Cromheecke, S.
    De Hert, S. G.
    [J]. ANAESTHESIA, 2007, 62 (10) : 979 - 983