Effect of waste landfill site on surface and ground water drinking quality

被引:24
作者
Amano, Kofi Owusu Ansah [1 ]
Danso-Boateng, Eric [2 ]
Adom, Ebenezer [3 ]
Kwame Nkansah, Desmond [3 ]
Amoamah, Ernest Sintim [3 ]
Appiah-Danquah, Emmanuel [4 ]
机构
[1] Otto von Guericke Univ, Inst Instrumental & Environm Technol, Dept Plant Design & Proc Safety, D-39106 Magdeburg, Germany
[2] Univ Leeds, Sch Chem Engn & Proc Engn, Leeds, W Yorkshire, England
[3] Kwame Nkrumah Univ Sci & Technol, Dept Chem Engn, Biotechnol Lab, Kumasi, Ghana
[4] Kwame Nkrumah Univ Sci & Technol, Dept Petr Engn, Kumasi, Ghana
关键词
drinking water quality; heavy metals pollution index; landfill; municipal solid waste; principal component analysis; water quality index; MUNICIPAL SOLID-WASTE; POLLUTION INDEX; RIVER-BASIN; LEACHATE; DISTRICT; AQUIFER; AREA;
D O I
10.1111/wej.12664
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Drinking water quality of surface and underground water within 1.34 km from a waste landfill site in Kumasi, Ghana was investigated. Physico-chemical properties and heavy metal concentrations were analysed to determine water quality and pollution indices. It was found that turbidity of 83% of hand dug wells, 50% of the streams and 33% of boreholes were higher than World Health Organisation (WHO) standards for drinking water. Water quality index (WQI) showed that 25% of the water sources are of excellent quality, while 50%, 15% and 5% are good quality, poor quality, very poor quality and unsuitable for drinking, respectively. Heavy metal pollution index (HPI) indicated that the water sources were above the critical limit for drinking water (HPI > 100). Principal component analysis (PCA) revealed 75.30% and 70.88% of the total variance for the physico-chemical parameters and heavy metals, respectively. The findings concluded that cadmium concentrations in all the water sources were extremely higher (0.0122-0.1090 mg/L) than WHO limit (0.003 mg/L), rendering them unwholesome for consumption.
引用
收藏
页码:715 / 729
页数:15
相关论文
共 57 条
  • [1] Rutin- and Selenium-attenuated cadmium-induced testicular pathophysiology in rats
    Abarikwu, S. O.
    Iserhienrhien, B. O.
    Badejo, T. A.
    [J]. HUMAN & EXPERIMENTAL TOXICOLOGY, 2013, 32 (04) : 395 - 406
  • [2] Addo I. B., 2015, CURR RES J SOCIAL SC, V7, P81, DOI DOI 10.19026/CRJSS.7.5225
  • [3] Amoah M.S., 2013, THESIS
  • [4] [Anonymous], 2008, Guidelines for drinking-water quality, V1, P317
  • [5] APHA, 2005, Standard Methods for the Examination of Water and Wastewater
  • [6] Appleby J.A., 1989, CANADIAN TECHNICAL R, V1681
  • [7] Argo B., 2013, J INT PHALAENOPSIS A, V13, P1
  • [8] Leachate pollution index as an effective tool in determining the phytotoxicity of municipal solid waste leachate
    Arunbabu, V.
    Indu, K. S.
    Ramasamy, E. V.
    [J]. WASTE MANAGEMENT, 2017, 68 : 329 - 336
  • [9] Contamination valuation of soil and groundwater source at anaerobic municipal solid waste landfill site
    Aziz, Shuokr Qarani
    Maulood, Yousif Ismael
    [J]. ENVIRONMENTAL MONITORING AND ASSESSMENT, 2015, 187 (12) : 1 - 11
  • [10] Bhalla B., 2014, INT J SCI ENV TECH, V3, P444