Improving Lung Lesion Detection in Low Dose Positron Emission Tomography Images Using Machine Learning

被引:0
|
作者
Nai, Yinghwey [1 ]
Schaefferkoetter, Joshua D. [1 ]
Fakhry-Darian, Daniel [1 ]
Conti, Maurizio [2 ]
Shi, Xinmei [1 ,3 ]
Townsend, David W. [1 ,4 ]
Sinha, Arvind K. [4 ]
Tham, Ivan [1 ,3 ]
Alexander, Daniel C. [5 ,6 ,7 ]
Reilhac, Anthonin [1 ]
机构
[1] A STAR NUS, Clin Imaging Res Ctr, Singapore, Singapore
[2] Siemens Med Solut USA Inc, Mol Imaging, Knoxville, TN USA
[3] Natl Univ Canc Inst, Dept Radiat Oncol, Singapore, Singapore
[4] Natl Univ Singapore Hosp, Dept Diagnost Radiol, Singapore, Singapore
[5] UCL, Ctr Med Image Comp, London, England
[6] UCL, Dept Comp Sci, London, England
[7] Natl Univ Singapore, Clin Imaging Res Ctr, Singapore, Singapore
来源
2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC) | 2018年
关键词
Image Quality Transfer; Lesion Detection; Lung Cancer; Machine Learning; Positron Emission Tomography;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Lung cancer suffers from poor prognosis, leading to high death rates. Combined PET/CT improves lung lesion detection but requires low dose protocols for frequent disease screening and monitoring. In this study, we investigate the feasibility of using machine learning to improve low dose PET images to standard dose, high-quality images for better lesion detection at low dose PET scans. We employ image quality transfer (IQT), which is a machine learning algorithm that uses patch-regression to map parameters from low to high-quality images e.g. enhancing resolution or information content. We acquired 20 standard dose PET images and simulated low dose PET images with 9 different count levels from the standard dose PET images. For each count levels, 10 pairs of standard dose PET images with one simulated low dose PET images were used to train linear, single non-linear regression tree, and random regression-forest models for IQT. The models were then used to estimate standard dose images from low dose images for each count levels for 10 different subjects. Improvement in image quality and lesion detection could be observed in the images estimated from the low dose images using IQT. Among the models employed, the regression tree model produced the best estimates of standard dose PET images. An average bias of less than 20% in SUVmean of 25 lesions in the estimated images from the standard dose PET images can be obtained down to 7.5 x 10(6) counts. Overall, despite the increase in bias, the improvement in image quality shows the potential of IQT in improving the accuracy in lesion detection.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] Machine learning application for classification of Alzheimer's disease stages using 18F-flortaucipir positron emission tomography
    Sang Won Park
    Na Young Yeo
    Jinsu Lee
    Suk-Hee Lee
    Junghyun Byun
    Dong Young Park
    Sujin Yum
    Jung-Kyeom Kim
    Gihwan Byeon
    Yeshin Kim
    Jae-Won Jang
    BioMedical Engineering OnLine, 22
  • [22] Machine learning application for classification of Alzheimer's disease stages using 18F-flortaucipir positron emission tomography
    Park, Sang Won
    Yeo, Na Young
    Lee, Jinsu
    Lee, Suk-Hee
    Byun, Junghyun
    Park, Dong Young
    Yum, Sujin
    Kim, Jung-Kyeom
    Byeon, Gihwan
    Kim, Yeshin
    Jang, Jae-Won
    BIOMEDICAL ENGINEERING ONLINE, 2023, 22 (01)
  • [23] A machine learning approach to automatic detection of irregularity in skin lesion border using dermoscopic images
    Ali, Abder-Rahman
    Li, Jingpeng
    Yang, Guang
    O'Shea, Sally Jane
    PEERJ COMPUTER SCIENCE, 2020, 6 : 1 - 35
  • [24] Lung Cancer Detection using Machine Learning Approach
    Hamim, Md Abrar
    Tanmoy, F. M.
    Asha, Umme Fatema Tuj
    Haq, Md Nazmul
    Alam, Maruf
    Ghosh, Bijoy
    2023 IEEE 22ND INTERNATIONAL CONFERENCE ON TRUST, SECURITY AND PRIVACY IN COMPUTING AND COMMUNICATIONS, TRUSTCOM, BIGDATASE, CSE, EUC, ISCI 2023, 2024, : 2676 - 2682
  • [25] Generation of virtual lung single-photon emission computed tomography/CT fusion images for functional avoidance radiotherapy planning using machine learning algorithms
    Jang, Bum-Sup
    Chang, Ji Hyun
    Park, Andrew J.
    Wu, Hong-Gyun
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2019, 63 (02) : 229 - 235
  • [26] Detection of non-aggressive stage IA lung cancer using chest computed tomography and positron emission tomography/computed tomography
    Shiono, Satoshi
    Yanagawa, Naoki
    Abiko, Masami
    Sato, Toru
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2014, 19 (04) : 637 - 643
  • [27] Validation of low-dose lung cancer PET-CT protocol and PET image improvement using machine learning
    Nai, Ying-Hwey
    Schaefferkoetter, Josh
    Fakhry-Darian, Daniel
    O'Doherty, Sophie
    Totman, John J.
    Conti, Maurizio
    Townsend, David W.
    Sinha, Arvind K.
    Tan, Teng-Hwee
    Tham, Ivan
    Alexander, Daniel C.
    Reilhac, Anthonin
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2021, 81 : 285 - 294
  • [28] Reconstruction of positron emission tomography images using adaptive sliced remeshing strategy
    Colmeiro, Ramiro R.
    Verrastro, Claudio
    Minsky, Daniel
    Grosges, Thomas
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (02)
  • [29] Machine and deep learning models for accurate detection of ischemia and scar with myocardial blood flow positron emission tomography imaging
    Berman, Daniel
    Hunter, Chad
    Hossain, Alomgir
    Yao, Jason
    Workman, Emily
    Guan, Steven
    Strickhart, Laura
    Beanlands, Rob
    Slater, David
    Dekemp, Robert A.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2024, 32
  • [30] IMPROVING MISPRONUNCIATION DETECTION USING MACHINE LEARNING
    Chen, Yuqiang
    Huang, Chao
    Soong, Frank
    2009 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, VOLS 1- 8, PROCEEDINGS, 2009, : 4865 - +