The Diamond I13 full-field transmission X-ray microscope: a Zernike phase-contrast setup for material sciences

被引:6
作者
Storm, Malte [1 ]
Doering, Florian [2 ]
Marathe, Shashidhara [1 ]
David, Christian [2 ]
Rau, Christoph [1 ,3 ,4 ]
机构
[1] Diamond Light Source Ltd, Didcot, Oxon, England
[2] Paul Scherrer Inst, Villigen, Switzerland
[3] Univ Manchester, Manchester, Lancs, England
[4] Northwestern Univ, Chicago, IL 60611 USA
关键词
tomography; synchrotron radiation; X-ray imaging; transmission X-ray microscopy; phase-contrast imaging;
D O I
10.1017/S0885715620000238
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
The I13 transmission X-ray microscope at Diamond Light Source (DLS) has been designed to cover a broad range of energies and field of views. The beamline operates on an undulator source, and a multilayer monochromator can be used to work at a larger bandwidth to enable faster acquisitions. The experimental design includes large working distances for the optics to allow installing in situ sample environments. This paper presents the current state of the experimental system and shows some of the latest results. (C) 2020 Diamond Light Source Ltd.
引用
收藏
页码:S8 / S14
页数:7
相关论文
共 12 条
[1]   Fast X-ray imaging at beamline I13L at Diamond Light Source [J].
De Fanis, A. ;
Pesic, Z. D. ;
Wagner, U. ;
Rau, C. .
11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
[2]   OPTIMUM ENERGIES FOR X-RAY TRANSMISSION TOMOGRAPHY OF SMALL SAMPLES - APPLICATIONS OF SYNCHROTRON RADIATION TO COMPUTERIZED-TOMOGRAPHY .1. [J].
GRODZINS, L .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 206 (03) :541-545
[3]  
Marathe Shashidhara, 2019, Proceedings of the SPIE, V11113, DOI 10.1117/12.2530698
[4]  
Peic Z. D., 2013, J PHYS C SER, V425
[5]   Coherent imaging at the Diamond beamline I13 [J].
Rau, Christoph ;
Wagner, Ulrich ;
Pesic, Zoran ;
De Fanis, Alberto .
PHYSICA STATUS SOLIDI A-APPLICATIONS AND MATERIALS SCIENCE, 2011, 208 (11) :2522-2525
[6]   PHASE-CONTRAST STUDIES OF BIOLOGICAL SPECIMENS WITH THE X-RAY MICROSCOPE AT BESSY [J].
SCHMAHL, G ;
RUDOLPH, D ;
GUTTMANN, P ;
SCHNEIDER, G ;
THIEME, J ;
NIEMANN, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :1282-1286
[7]   Phase-contrast tomography at the nanoscale using hard x rays [J].
Stampanoni, Marco ;
Mokso, Rajmund ;
Marone, Federica ;
Vila-Comamala, Joan ;
Gorelick, Sergey ;
Trtik, Pavel ;
Jefimovs, Konstantin ;
David, Christian .
PHYSICAL REVIEW B, 2010, 81 (14)
[8]  
Storm M., 2018, MICROSC MICROANAL, V24, P216, DOI [10.1017/S1431927618013430, DOI 10.1017/S1431927618013430]
[9]   Fourier shell correlation threshold criteria [J].
van Heel, M ;
Schatz, M .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 151 (03) :250-262
[10]   Halo suppression in full-field x-ray Zernike phase contrast microscopy [J].
Vartiainen, Ismo ;
Mokso, Rajmund ;
Stampanoni, Marco ;
David, Christian .
OPTICS LETTERS, 2014, 39 (06) :1601-1604