Atrioventricular Conduction Changes After CoreValve Transcatheter Aortic Valve Implantation

被引:13
作者
Lopez-Aguilera, Jose [1 ]
Segura Saint-Gerons, Jose Maria [1 ]
Mazuelos Bellido, Francisco [1 ]
Suarez de Lezo, Javier [1 ]
Ojeda Pineda, Soledad [1 ]
Pan Alvarez-Ossorio, Manuel [1 ]
Romero Moreno, Miguel Angel [1 ]
Pavlovic, Djordje [1 ]
Espejo Perez, Simona [2 ]
Suarez de Lezo, Jose [1 ]
机构
[1] Hosp Univ Reina Sofia, Serv Cardiol, Cordoba, Spain
[2] Hosp Univ Reina Sofia, Serv Radiodiagnost, Cordoba, Spain
来源
REVISTA ESPANOLA DE CARDIOLOGIA | 2016年 / 69卷 / 01期
关键词
CoreValve; Pacemaker; Electrophysiology; PACEMAKER; DISTURBANCES; STENOSIS; ANATOMY; RISK;
D O I
10.1016/j.rec.2015.02.026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction and objectives: Conduction disturbances often occur after CoreValve transcatheter aortic valve implantation. The aim was to analyze which cardiac conduction changes occur in patients with aortic stenosis treated with this type of prosthesis. Methods: A total of 181 patients with severe aortic stenosis treated with this prosthesis and studied by electrocardiography between April 2008 and December 2013 were selected. A subgroup of 137 (75.7%) consecutive patients was studied by intracardiac electrocardiogram before and after prosthesis implantation. The primary endpoint of the study was the need for a permanent pacemaker within 72 hours after prosthesis implantation. Numerous variables to predict this possibility were analyzed. Results: Following implantation, PR and QRS intervals were increased from 173 +/- 47 ms to 190 +/- 52 ms (P < .01) and from 98 +/- 22 ms to 129 +/- 24 ms (P < .01), whereas the A-H and H-V intervals were prolonged from 95 +/- 39 ms to 108 +/- 41 ms (P < .01) and from 54 +/- 10 ms to 66 +/- 23 ms (P <.01). A total of 89 (49%) patients had new-onset left bundle-branch block, and 33 (25%) required a pacemaker within the first 72 hours. The independent predictors for a pacemaker were baseline right bundle-branch block and prosthetic depth. Intracardiac intervals had no predictive value. In addition, 13 patients required a pacemaker after 72 hours. Conclusions: CoreValve prosthesis implantation has a high incidence of conduction disturbance, with left bundle- branch block being the most common. A total of 25% of patients required a permanent pacemaker. The need for a pacemaker was related to baseline right bundle- branch block and prosthetic depth. (C) 2015 Sociedad Espanola de Cardiologia. Published by Elsevier Espana, S.L.U. All rights reserved.
引用
收藏
页码:28 / 36
页数:9
相关论文
共 16 条
[1]  
CRIBIER A, 1986, ARCH MAL COEUR VAISS, V79, P1678
[2]  
Eksik A, 2013, J INVASIVE CARDIOL, V25, P305
[3]   Risk for Permanent Pacemaker After Transcatheter Aortic Valve Implantation: A Comprehensive Analysis of the Literature [J].
Erkapic, Damir ;
De Rosa, Salvatore ;
Kelava, Augustin ;
Lehmann, Ralf ;
Fichtlscherer, Stephan ;
Hohnloser, Stefan H. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (04) :391-397
[4]   Electrocardiographic changes and clinical outcomes after transapical aortic valve implantation [J].
Gutierrez, Marcos ;
Rodes-Cabau, Josep ;
Bagur, Rodrigo ;
Doyle, Daniel ;
DeLarochelliere, Robert ;
Bergeron, Sebastien ;
Lemieux, Jerome ;
Villeneuve, Jacques ;
Cote, Melanie ;
Bertrand, Olivier F. ;
Poirier, Paul ;
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Dumont, Eric .
AMERICAN HEART JOURNAL, 2009, 158 (02) :302-308
[5]   Development and validation of a simple risk score to predict the need for permanent pacing after cardiac valve surgery [J].
Koplan, BA ;
Stevenson, WG ;
Epstein, LM ;
Aranki, SF ;
Maisel, WH .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (05) :795-801
[6]   "Device Landing Zone" Calcification, Assessed by MSCT, as a Predictive Factor for Pacemaker Implantation After TAVI [J].
Latsios, George ;
Gerckens, Ulrich ;
Buellesfeld, Lutz ;
Mueller, Ralf ;
John, Daniel ;
Yuecel, Seyrani ;
Syring, Joerg ;
Sauren, Barthel ;
Grube, Eberhard .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 76 (03) :431-439
[7]   Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery. [J].
Leon, Martin B. ;
Smith, Craig R. ;
Mack, Michael ;
Miller, D. Craig ;
Moses, Jeffrey W. ;
Svensson, Lars G. ;
Tuzcu, E. Murat ;
Webb, John G. ;
Fontana, Gregory P. ;
Makkar, Raj R. ;
Brown, David L. ;
Block, Peter C. ;
Guyton, Robert A. ;
Pichard, Augusto D. ;
Bavaria, Joseph E. ;
Herrmann, Howard C. ;
Douglas, Pamela S. ;
Petersen, John L. ;
Akin, Jodi J. ;
Anderson, William N. ;
Wang, Duolao ;
Pocock, Stuart .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (17) :1597-1607
[8]   Conduction Disorders and Transcatheter Aortic Valve. Clinically Relevant or Just a Mild Complication? [J].
Moris, Cesar ;
Rubin, Jose M. .
REVISTA ESPANOLA DE CARDIOLOGIA, 2013, 66 (09) :692-694
[9]   Changes in Atrioventricular Conduction and Predictors of Pacemaker Need After Percutaneous Implantation of the CoreValve® Aortic Valve Prosthesis [J].
Munoz-Garcia, Antonio J. ;
Hernandez-Garcia, Jose M. ;
Jimenez-Navarro, Manuel F. ;
Alonso-Briales, Juan H. ;
Rodriguez-Bailon, Isabel ;
Pena-Hernandez, Jose ;
Fernandez-Pastor, Julia ;
Dominguez-Franco, Antonio J. ;
Barrera-Cordero, Alberto ;
Alzueta-Rodriguez, Javier ;
de Teresa Galvan, Eduardo .
REVISTA ESPANOLA DE CARDIOLOGIA, 2010, 63 (12) :1444-1451
[10]   Determinants of pacemaker dependency after coronary and/or mitral or aortic valve surgery with long-term follow-up [J].
Onalan, Orhan ;
Crystal, Alexander ;
Lashevsky, Ilan ;
Khalameizer, Vladimir ;
Lau, Ching ;
Goldman, Bernard ;
Fremes, Stephen ;
Newman, David ;
Lukomsky, Maria ;
Crystal, Eugene .
AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (02) :203-208