Time Weighted Average Concentration Monitoring Based on Thin Film Solid Phase Microextraction

被引:31
作者
Ahmadi, Fardin [1 ]
Sparham, Chris [2 ]
Boyaci, Ezel [1 ]
Pawliszyn, Janusz [1 ]
机构
[1] Univ Waterloo, Dept Chem, 200 Univ Ave West, Waterloo, ON N2L 3G1, Canada
[2] Unilever Safety & Environm Assurance Ctr, Colworth Sci Pk, Bedford MK44 1LQ, England
基金
加拿大自然科学与工程研究理事会;
关键词
TANDEM MASS-SPECTROMETRY; SEMIPERMEABLE-MEMBRANE DEVICES; PASSIVE SAMPLING DEVICES; ORGANIC UV FILTERS; LIQUID-CHROMATOGRAPHY; WASTE-WATER; ON-SITE; AQUATIC ENVIRONMENT; AQUEOUS SAMPLES; SURFACE WATERS;
D O I
10.1021/acs.est.6b06465
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Time weighted average (TWA) passive sampling with thin film solid: phase micro extraction (TF-SPME) and liquid chromatography tandem mass spectrometry (LC-MS/MS) was used for collection, identification, and quantification of benzophenone-1, benzophenone-2, benzophenone-3, benzophenone-4, 2-phenylbenzimidazole-5-sulfonic acid, octocrylene, octylmethoxycinnamate, butylmethoxydibenzgylmethane, triclocarban and triclosan in the aquatic environment. Two types of TF-SPME passive samplers, including a retracted thin film device using a hydrophilic lipophilic balance (HLB) coating, and an open-bed configuration with an, octadecyl silica-based (C18) coating, were evaluated in an aqueous standard generation system. Laboratory calibration results indicated that the thin film retracted device using HLB coating is suitable to determine TWA concentrations of polar analytes in water, with an uptake that was linear up to 70 days. In open bed form, a one-calibrant kinetic calibration technique was accomplished by loading benzophenone3-d(5) as calibrant on the C18 coating to quantify all nonpolar compounds. The experimental results showed that the one-calibrant kinetic calibration technique can be used for determination of classes of compounds in cases where deuterated counterparts are either not available or expensive. The developed passive samplers were deployed in wastewater-dominated reaches of the Grand River (Kitchener, ON) to verify their feasibility for determination of TWA concentrations in on-site applications. Field trials, results indicated that these devices are suitable for long-term and short-term monitoring of compounds varying in polarity, such as UV blockers and biocide compounds in water, and the data were in good agreement with literature data.
引用
收藏
页码:3929 / 3937
页数:9
相关论文
共 58 条
[1]   Calibration and use of the Chemcatcher® passive sampler for monitoring organotin compounds in water [J].
Aguilar-Martinez, R. ;
Palacios-Corvillo, M. A. ;
Greenwood, R. ;
Mills, G. A. ;
Vrana, B. ;
Gomez-Gomez, M. M. .
ANALYTICA CHIMICA ACTA, 2008, 618 (02) :157-167
[2]   Passive sampling for target and nontarget analyses of moderately polar and nonpolar substances in water [J].
Allan, Ian J. ;
Harman, Christopher ;
Ranneklev, Sissel B. ;
Thomas, Kevin V. ;
Grung, Merete .
ENVIRONMENTAL TOXICOLOGY AND CHEMISTRY, 2013, 32 (08) :1718-1726
[3]   Effect of sampler material on the uptake of PAHs into passive sampling devices [J].
Allan, Ian J. ;
Harman, Christopher ;
Kringstad, Alfhild ;
Bratsberg, Erling .
CHEMOSPHERE, 2010, 79 (04) :470-475
[4]   Field Performance of Seven Passive Sampling Devices for Monitoring of Hydrophobic Substances [J].
Allan, Ian J. ;
Booij, Kees ;
Paschke, Albrecht ;
Vrana, Branislav ;
Mills, Graham A. ;
Greenwood, Richard .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2009, 43 (14) :5383-5390
[5]   Comparison of a novel passive sampler to standard water-column sampling for organic contaminants associated with wastewater effluents entering a New Jersey stream [J].
Alvarez, DA ;
Stackelberg, PE ;
Petty, JD ;
Huckins, JN ;
Furlong, ET ;
Zaugg, SD ;
Meyer, MT .
CHEMOSPHERE, 2005, 61 (05) :610-622
[6]   SOLID-PHASE MICROEXTRACTION WITH THERMAL-DESORPTION USING FUSED-SILICA OPTICAL FIBERS [J].
ARTHUR, CL ;
PAWLISZYN, J .
ANALYTICAL CHEMISTRY, 1990, 62 (19) :2145-2148
[7]   Occurrence of some organic UV filters in wastewater, in surface waters, and in fish from Swiss lakes [J].
Balmer, ME ;
Buser, HR ;
Müller, MD ;
Poiger, T .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (04) :953-962
[8]   Application of Polar Organic Chemical Integrative Sampler (POCIS) to monitor emerging contaminants in tropical waters [J].
Bayen, Stephane ;
Segovia, Elvagris ;
Loh, Lay Leng ;
Burger, David F. ;
Eikaas, Hans S. ;
Kelly, Barry C. .
SCIENCE OF THE TOTAL ENVIRONMENT, 2014, 482 :15-22
[9]   SPME - Quo vadis? [J].
Bojko, Barbara ;
Cudjoe, Erasmus ;
Gomez-Rios, German A. ;
Gorynski, Krzysztof ;
Jiang, Ruifen ;
Reyes-Garces, Nathaly ;
Risticevic, Sanja ;
Silva, Erica A. S. ;
Togunde, Oluranti ;
Vuckovic, Dajana ;
Pawliszyn, Janusz .
ANALYTICA CHIMICA ACTA, 2012, 750 :132-151
[10]   Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment [J].
Booij, Kees ;
Robinson, Craig D. ;
Burgess, Robert M. ;
Mayer, Philipp ;
Roberts, Cindy A. ;
Ahrens, Lutz ;
Allan, Ian J. ;
Brant, Jan ;
Jones, Lisa ;
Kraus, Uta R. ;
Larsen, Martin M. ;
Lepom, Peter ;
Petersen, Joerdis ;
Proefrock, Daniel ;
Roose, Patrick ;
Schaefer, Sabine ;
Smedes, Foppe ;
Tixier, Celine ;
Vorkamp, Katrin ;
Whitehouse, Paul .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2016, 50 (01) :3-17