Ultrasound Cavitation/Microbubble Detection and Medical Applications

被引:91
作者
Izadifar, Zahra [1 ]
Babyn, Paul [2 ,3 ]
Chapman, Dean [4 ]
机构
[1] Univ Saskatchewan, Div Biomed Engn, Coll Engn, 57 Campus Dr, Saskatoon, SK S7N 5A9, Canada
[2] Univ Saskatchewan, Dept Med Imaging, 103 Hosp Dr, Saskatoon, SK S7N 0W8, Canada
[3] Royal Univ Hosp, Saskatoon Hlth Reg, 103 Hosp Dr, Saskatoon, SK S7N 0W8, Canada
[4] Univ Saskatchewan, Anat & Cell Biol, 3B34 Hlth Sci Bldg,107 Wiggins Rd, Saskatoon, SK S7N 5E5, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Ultrasound; Detection technique; Cavitation bubble; Microbubble contrast agent; BLOOD-BRAIN-BARRIER; INTENSITY FOCUSED ULTRASOUND; TARGETED MICROBUBBLE DESTRUCTION; INDUCED CAVITATION BUBBLES; LOW-FREQUENCY ULTRASOUND; ACOUSTIC CAVITATION; CONTRAST AGENTS; GENE DELIVERY; IN-VITRO; DRUG-DELIVERY;
D O I
10.1007/s40846-018-0391-0
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Over the past decades, different techniques have been investigated for detecting microbubbles. The purpose of this work is to review the state-of-the-art of medical microbubble detection along with therapeutic, monitoring, and diagnostic applications. The presence of microbubbles in the human body can be induced either through cavitation or exogenous introduction of bubbles. One of the effects of ultrasound is cavitation, or microbubble formation and collapse. Cavitation produces high pressures and temperatures, and microbubble expansion and then collapse close to cells can lead to cellular damage or hemorrhage in biological tissues. Cavitation is, in most cases, an undesired event in clinical diagnostic imaging. Considering that cavitation microbubble formation is largely unpredictable, ultrasound imaging may present a rare or yet unknown risk, particularly to fetuses and embryos. Although most therapeutic ultrasound modalities work based on physical and thermal effects of cavitation, the safety of treatment strongly depends on accurate knowledge of the location of the cavitation inception point. Cavitation detection is an important factor with respect to improving the safety of ultrasound imaging and therapy. It is essential to recognize the existence and location of cavitation inception points. In addition, the use of encapsulated microbubbles as contrast agents for diagnostic imaging, as vehicles for local drug or gene delivery, and as tools for microbubble and ultrasound therapy in thrombolysis has increased the demand for an accurate deep tissue microbubble detection technique. There have been many attempts to detect cavitation bubbles, but each contains its own limitations. There is no doubt that continuous discoveries and developments in microbubble detection modalities will lead to safer and more efficient therapeutic and diagnostic equipment.
引用
收藏
页码:259 / 276
页数:18
相关论文
共 133 条
  • [1] Low-frequency ultrasound penetrates the cranium and enhances thrombolysis in vitro
    Akiyama, M
    Ishibashi, T
    Yamada, T
    Furuhata, H
    [J]. NEUROSURGERY, 1998, 43 (04) : 828 - 832
  • [2] GAUGING THE LIKELIHOOD OF CAVITATION FROM SHORT-PULSE, LOW-DUTY CYCLE DIAGNOSTIC ULTRASOUND
    APFEL, RE
    HOLLAND, CK
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (02) : 179 - 185
  • [3] Microbubbles as x-ray scattering contrast agents using analyzer-based imaging
    Arfelli, F.
    Rigon, L.
    Menk, R. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (06) : 1643 - 1658
  • [4] THE CREVICE MODEL OF BUBBLE NUCLEATION
    ATCHLEY, AA
    PROSPERETTI, A
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1989, 86 (03) : 1065 - 1084
  • [5] THRESHOLDS FOR CAVITATION PRODUCED IN WATER BY PULSED ULTRASOUND
    ATCHLEY, AA
    FRIZZELL, LA
    APFEL, RE
    HOLLAND, CK
    MADANSHETTY, S
    ROY, RA
    [J]. ULTRASONICS, 1988, 26 (05) : 280 - 285
  • [6] Cavitation detection during shock-wave lithotripsy
    Bailey, MR
    Pishchalnikov, YA
    Sapozhnikov, OA
    Cleveland, RO
    McAteer, JA
    Miller, NA
    Pishchalnikova, IV
    Connors, BA
    Crum, LA
    Evan, AP
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2005, 31 (09) : 1245 - 1256
  • [7] Comparison of electrohydraulic lithotripters with rigid and pressure-release ellipsoidal reflectors. I. Acoustic fields
    Bailey, MR
    Blackstock, DT
    Cleveland, RO
    Crum, LA
    [J]. JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1998, 104 (04) : 2517 - 2524
  • [8] In vitro modulation of intracellular oxidative stress of endothelial cells by diagnostic cardiac ultrasound
    Basta, G
    Venneri, L
    Lazzerini, G
    Pasanisi, E
    Pianelli, M
    Vesentini, N
    Del Turco, S
    Kusmic, C
    Picano, E
    [J]. CARDIOVASCULAR RESEARCH, 2003, 58 (01) : 156 - 161
  • [9] Ultrasound-targeted microbubble destruction can repeatedly direct highly specific plasmid expression to the heart
    Bekeredjian, R
    Chen, SY
    Frenkel, PA
    Grayburn, PA
    Shohet, RV
    [J]. CIRCULATION, 2003, 108 (08) : 1022 - 1026
  • [10] On the effect of lung filtering and cardiac pressure on the standard properties of ultrasound contrast agent
    Bouakaz, A
    de Jong, N
    Cachard, C
    Jouini, K
    [J]. ULTRASONICS, 1998, 36 (1-5) : 703 - 708