The impact of dental metal artifacts on head and neck IMRT dose distributions

被引:52
作者
Kim, Yusung
Tome, Wolfgang A.
Bal, Matthieu
McNutt, Todd R.
Spies, Lothar
机构
[1] Univ Wisconsin, Sch Med, Dept Human Oncol, Madison, WI 53792 USA
[2] Univ Wisconsin, Sch Med, Dept Med Phys, Madison, WI 53792 USA
[3] Philips Res Labs, Aachen, Germany
[4] Johns Hopkins Univ, Dept Radiat Oncol, Baltimore, MD USA
关键词
metal artifacts; treatment planning; head and neck;
D O I
10.1016/j.radonc.2006.03.022
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purposes: To quantify the cold or hot spot induced in IMRT treatment plans due to the presence of metal artifact in CT image data sets stemming from dental work. Patients and methods: Metal artifact corrected image data sets of five patients have been analyzed. IMRT plans were generated using five different planning image data sets: (a) uncorrected (UC) (b) homogeneous uncorrected (HUC), (c) sinogram completion corrected (SCC), (d) minimum value corrected (MVC), and (e) image set (d) subsequently corrected with a streak artifacts reduction algorithm (SAR-MVC). The SAR-MVC data set is assumed to be the closest approximation to the absence of metal artifacts and has therefore been taken as the reference image data set. An IMRT plan was generated for each of the image datasets (a)-(e). The resulting IMRT treatment plans for data sets (a)-(d) were then projected onto the reference data set (e) and recalculated. The reference dose distribution (e) was then subtracted from these recalculated dose distributions. Using dose difference analysis, the cold and hot spots in organs at risk (OARS) and the target volumes (TVs) were quantified. Results: When compared to the reference dose distribution, the UC, HUC, and SCC plans exhibited hot spots showing on average more than 1.0 Gy hot dose in the left and right parotids. For the UC, HUC, and SCC recalculated plans, subvolumes of the clinical target volumes (CTV) were under dosed on average by more than 0.9 Gy. On the other hand, the MVC plan showed less than 0.3 Gy hot dose in both parotids, and the cold dose in the CTVs were reduced by up to 0.8 Gy. Conclusions: The presence of dental metal artifacts in head and neck planning CT data sets can lead to relative hot spots in OARS and relative cold spots in regions of the TVs when compared to the reference data set that more closely approximates the patient anatomy. This effect can be reduced if a simple minimum value correction (MVC) method for the dental metal artifacts is employed. (c) 2006 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:198 / 202
页数:5
相关论文
共 19 条
[1]   Determination and delineation of nodal target volumes for head-and-neck cancer based on patterns of failure in patients receiving definitive and postoperative IMRT [J].
Chao, KSC ;
Wippold, FJ ;
Ozyigit, G ;
Tran, BN ;
Dempsey, JF .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 53 (05) :1174-1184
[2]   CERR: A computational environment for radiotherapy research [J].
Deasy, JO ;
Blanco, AI ;
Clark, VH .
MEDICAL PHYSICS, 2003, 30 (05) :979-985
[3]   Parotid gland sparing in patients undergoing bilateral head and neck irradiation: Techniques and early results [J].
Eisbruch, A ;
Ship, JA ;
Martel, MK ;
TenHaken, RK ;
Marsh, LH ;
Wolf, GT ;
Esclamado, RM ;
Bradford, CR ;
Terrell, JE ;
Gebarski, SS ;
Lichter, AS .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (02) :469-480
[4]   Dose, volume, and function relationships in parotid salivary glands following conformal and intensity-modulated irradiation of head and neck cancer [J].
Eisbruch, A ;
Ten Haken, RK ;
Kim, HM ;
Marsh, LH ;
Ship, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (03) :577-587
[5]   Selection and delineation of lymph node target volumes in head and neck conformal radiotherapy.: Proposal for standardizing terminology and procedure based on the surgical experience [J].
Grégoire, V ;
Coche, E ;
Cosnard, G ;
Hamoir, M ;
Reychler, H .
RADIOTHERAPY AND ONCOLOGY, 2000, 56 (02) :135-150
[6]   The impact of daily setup variations on head-and-neck intensity-modulated radiation therapy [J].
Hong, TS ;
Tomé, WA ;
Chappell, RJ ;
Chinnaiyan, P ;
Mehta, MP ;
Harari, PM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :779-788
[7]  
HSIEH J, 1995, MED CT ULTRASOUND CU, P487
[8]   Treatment planning and delivery of intensity-modulated radiation therapy for primary nasopharynx cancer [J].
Hunt, MA ;
Zelefsky, MJ ;
Wolden, S ;
Chui, CS ;
LoSasso, T ;
Rosenzweig, K ;
Chong, L ;
Spirou, SV ;
Fromme, L ;
Lumley, M ;
Amols, HA ;
Ling, CL ;
Leibel, SA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03) :623-632
[9]  
MACKIE TR, 2003, INTENSITY MODULATED, P247
[10]   A three-dimensional CT-based target definition for elective irradiation of the neck [J].
Nowak, PJCM ;
Wijers, OB ;
Lagerwaard, FJ ;
Levendag, PC .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (01) :33-39