Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator

被引:83
作者
Groh, Christopher A. [1 ]
Sharma, Shishir [1 ]
Pelchovitz, Daniel J. [1 ]
Bhave, Prashant D. [1 ]
Rhyner, John [1 ]
Verma, Nishant [1 ]
Arora, Rishi [1 ]
Chicos, Alexandru B. [1 ]
Kim, Susan S. [1 ]
Lin, Albert C. [1 ]
Passman, Rod S. [1 ]
Knight, Bradley P. [1 ]
机构
[1] Northwestern Univ, Dept Med, Div Cardiol, Chicago, IL 60611 USA
关键词
Subcutaneous implantable cardioverter-defibrillator; T-wave oversensing; Defibrillator screening; Implantable cardioverter-defibrillator; Inappropriate shocks; CLINICAL-EXPERIENCE; EFFICACY; SHOCKS;
D O I
10.1016/j.hrthm.2014.04.025
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND An electrocardiographic (ECG) screening test has been developed to identify patients being considered for a totally subcutaneous implantable cardioverter-defibrillator (S-ICD) at risk for 1-wave oversensing. OBJECTIVE The purpose of this study was to determine the proportion of potential S-ICD recipients who fail the ECG screening test and to identify predictors of failure. METHODS Patients who already have an ICD but are not receiving antibradycardia pacing are representative of patients who might be considered for an S-ICD. One hundred such outpatients were enrolled in the study. Surface rhythm strips were recorded along the sensing vectors of the S-ICD system and the screening template applied. Clinical and standard ECG characteristics of patients who failed the test were compared to those who passed. RESULTS Patients had the following characteristics: 72% male, age 57 +/- 16 years, body mass index 29 +/- 6 kg/m(2), left ventricular ejection fraction 43% +/- 17%, ORS duration 109 +/- 23 ms, QTc interval 447 +/- 39 ms, 44% had coronary disease, and 55% had heart failure. Among the 100 patients, 8% failed the screening test. There were no differences in patient clinical characteristics and most standard ECG measurements. However, patients with 1-wave inversions in standard ECG leads I, II, and aVF had a 45% chance of failing. CONCLUSION Eight percent of potential S-ICD patients were not eligible for the S-ICD after failing the screening test designed to identify patients susceptible to 1-wave oversensing. Patients with 1-wave inversions in leads I, II, and aVF on a standard ECG were 23 times more likely to fail. More work is needed in S-ICD sensing algorithms to increase patient eligibility for the S-ICD.
引用
收藏
页码:1361 / 1366
页数:6
相关论文
共 12 条
[1]   Clinical experience with a novel subcutaneous implantable defibrillator system in a single center [J].
Abkenari, Lara Dabiri ;
Theuns, Dominic A. M. J. ;
Valk, Suzanne D. A. ;
Van Belle, Yves ;
de Groot, Natasja M. ;
Haitsma, David ;
Muskens-Heemskerk, Agnes ;
Szili-Torok, Tamas ;
Jordaens, Luc .
CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (09) :737-744
[2]   Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience [J].
Aydin, Ali ;
Hartel, Friederike ;
Schlueter, Michael ;
Butter, Christian ;
Koebe, Julia ;
Seifert, Martin ;
Gosau, Nils ;
Hoffmann, Boris ;
Hoffmann, Matthias ;
Vettorazzi, Eik ;
Wilke, Iris ;
Wegscheider, Karl ;
Reichenspurner, Hermann ;
Eckardt, Lars ;
Steven, Daniel ;
Willems, Stephan .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (05) :913-919
[3]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[4]   Inappropriate implantable cardioverter-defibrillator shocks in MADIT II [J].
Daubert, James P. ;
Zareba, Wojciech ;
Cannom, David S. ;
McNitt, Scott ;
Rosero, Spencer Z. ;
Wang, Paul ;
Schuger, Claudio ;
Steinberg, Jonathan S. ;
Higgins, Steven L. ;
Wilber, David J. ;
Klein, Helmut ;
Andrews, Mark L. ;
Hall, W. Jackson ;
Moss, Arthur J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) :1357-1365
[5]   Inappropriate subcutaneous implantable cardioverter-defibrillator shocks due to T-wave oversensing can be prevented: Implications for management [J].
Kooiman, Kirsten M. ;
Knops, Reinoud E. ;
Nordkamp, Louise Olde ;
Wilde, Arthur A. M. ;
de Groot, Joris R. .
HEART RHYTHM, 2014, 11 (03) :426-434
[6]   ANALYSIS OF T-WAVE ABNORMALITIES ASSOCIATED WITH MYOCARDIAL INFARCTION USING A THEORETIC MODEL [J].
MANDEL, WJ ;
BURGESS, MJ ;
NEVILLE, J ;
ABILDSKO.JA .
CIRCULATION, 1968, 38 (01) :178-&
[7]   Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia [J].
Moss, AJ ;
Hall, WJ ;
Cannom, DS ;
Daubert, JP ;
Higgins, SL ;
Klein, H ;
Levine, JH ;
Saksena, S ;
Waldo, AL ;
Wilber, D ;
Brown, MW ;
Heo, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (26) :1933-1940
[8]   Which Patients Are Not Suitable for a Subcutaneous ICD: Incidence and Predictors of Failed QRS-T-Wave Morphology Screening [J].
Nordkamp, Louise R. A. Olde ;
Warnaars, Joppe L. F. ;
Kooiman, Kirsten M. ;
de GROOT, Joris R. ;
Rosenmoeller, Boudewijn R. A. M. ;
Wilde, Arthur A. M. ;
Knops, Reinoud E. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (05) :494-499
[9]   The Entirely Subcutaneous Implantable Cardioverter-Defibrillator Initial Clinical Experience in a Large Dutch Cohort [J].
Nordkamp, Louise R. A. Olde ;
Abkenari, Lara Dabiri ;
Boersma, Lucas V. A. ;
Maass, Alexander H. ;
de Groot, Joris R. ;
van Oostrom, Antonie J. H. H. M. ;
Theuns, Dominic A. M. J. ;
Jordaens, Luc J. L. M. ;
Wilde, Arthur A. M. ;
Knops, Reinoud E. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (19) :1933-1939
[10]  
Randles DA, 2013, EUROPACE