Enhanced biological phosphorus removal in the retrofitting from an anoxic selector to an anaerobic selector in a full-scale activated sludge process in Singapore

被引:5
作者
Cao, Y. [1 ]
Ang, C. M. [1 ]
Chua, K. C. [2 ]
Woo, F. W. [2 ]
Chi, H. [2 ]
Bhawna, B. [2 ]
Chong, C. T. [2 ]
Ganesan, N. [2 ]
Ooi, K. E. [2 ]
Wah, Y. L. [2 ]
机构
[1] Ctr Adv Water Technol, Singapore 608575, Singapore
[2] PUB, Singapore 228231, Singapore
关键词
activated sludge; denitrifying phosphorus removal; energy saving; enhanced biological phosphorus removal; municipal sewage treatment; nutrient removal; phosphorus accumulating organism; selector; WASTE-WATER; SYSTEMS; PERFORMANCE;
D O I
10.2166/wst.2009.025
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents the investigation results of retrofitting an anoxic selector to an anaerobic selector through stepwise reduction of air supply in a full-scale activated sludge process with a focus on enhanced biological phosphorus removal (EBPR). The process experienced gradual shift from a Ludzack-Ettinger (LE) to an anaerobic-anoxic-oxic (A(2)O) process and subsequently, an anaerobic-oxic (A/O) process. The major findings are: (i) the average influent-based PO(4)(3-)-P release in the anaerobic selector compartment was 16.3 mg P l(-1) and that in the secondary clarifier was 1.7 mg P l(-1). 75% of the SCOD and 93% of the acetic acid in the primary effluent were taken up in the anaerobic selector compartment, respectively; (ii) PO(4)(3-)-P uptake contributed by both aerobic and denitrifying phosphorus accumulating organisms (DPAOs) occurred mainly in the first and second aerobic lanes together with simultaneous nitrification and denitrification (SND) while there was not much contribution from the last aerobic lane; (iii) The average PO(4)(3-)-P concentration of the final effluent was 2.4 mg P l(-1) corresponding to a removal efficiency of 85%; (iv) the SVI was satisfactory after retrofitting; and (v) the increase of NH(4)(+)-N in the final effluent from the commencement to the completion of the retrofitting resulted in an approximate 40-50% reduction in oxygen demand and a significant aeration energy saving was achieved.
引用
收藏
页码:857 / 865
页数:9
相关论文
共 15 条
[1]   Denitrification behaviour in biological excess phosphorus removal activated sludge systems [J].
Barker, PS ;
Dold, PL .
WATER RESEARCH, 1996, 30 (04) :769-780
[2]  
Cao Y., 2008, BIOL NITROGEN REMOVA
[3]   Analysis of phosphorus removal and anaerobic selector performance in a full-scale activated sludge process in Singapore [J].
Cao, Y. S. ;
Ang, C. M. ;
Raajeevan, K. S. ;
Kiran, A. K. ;
Lai, K. C. ;
Ng, S. W. ;
Zulkifli, I. ;
Wah, Y. L. .
WATER SCIENCE AND TECHNOLOGY, 2006, 54 (08) :237-246
[4]   Performance analysis of anoxic selector in upgrading activated sludge process in tropical climate [J].
Cao, YS ;
Teo, KH ;
Yuen, WA ;
Long, WY ;
Seah, B .
WATER SCIENCE AND TECHNOLOGY, 2005, 52 (04) :27-37
[5]  
CAO YS, 2005, 1 IWA ASPIRE ASI PAC
[6]   THE SELECTOR EFFECT ON FILAMENTOUS BULKING IN LONG SLUDGE AGE ACTIVATED-SLUDGE SYSTEMS [J].
GABB, DMD ;
STILL, DA ;
EKAMA, GA ;
JENKINS, D ;
MARAIS, GVR .
WATER SCIENCE AND TECHNOLOGY, 1991, 23 (4-6) :867-877
[7]   Anoxic growth of phosphate-accumulating organisms (PAOs) in biological nutrient removal activated sludge systems [J].
Hu, ZR ;
Wentzel, MC ;
Ekama, GA .
WATER RESEARCH, 2002, 36 (19) :4927-4937
[8]   BIOLOGICAL PHOSPHORUS UPTAKE UNDER ANOXIC AND AEROBIC CONDITIONS [J].
KERRNJESPERSEN, JP ;
HENZE, M .
WATER RESEARCH, 1993, 27 (04) :617-624
[9]   Occurrence of denitrifying phosphorus removing bacteria in modified UCT-type wastewater treatment plants [J].
Kuba, T ;
VanLoosdrecht, MCM ;
Brandse, FA ;
Heijnen, JJ .
WATER RESEARCH, 1997, 31 (04) :777-786
[10]   Carbon and phosphorus transformations in a full-scale enhanced biological phosphorus removal process [J].
Lie, E ;
Christensson, M ;
Jonsson, K ;
Ostgaard, K ;
Johansson, P ;
Welander, T .
WATER RESEARCH, 1997, 31 (11) :2693-2698