Comparison study of the axial length measured using the new swept-source optical coherence tomography ANTERION and the partial coherence interferometry IOL Master

被引:28
作者
Kim, Kook Young [1 ]
Choi, Gon Soo [1 ]
Kang, Min Seok [1 ]
Kim, Ungsoo Samuel [1 ]
机构
[1] Kims Eye Hosp, Seoul, South Korea
关键词
BIOMETER; ERROR;
D O I
10.1371/journal.pone.0244590
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Purpose To compare a biometer using swept-source optical coherence tomography (SS-OCT) with a partial coherence interferometry (PCI)-based biometer in measurements of two ocular biometry parameters, i.e., the axial length and anterior cornea curvature. Methods We compared the two biometers SS-OCT (ANTERION, Heidelberg Engineering Inc., Heidelberg, Germany) and PCI (IOL Master, Carl Zeiss Meditec, Jena, Germany) in terms of the axial length (AL) and corneal curvature (K) measurements of 175 eyes. Paired t-tests were used to compare the two biometers. Agreement between the biometers was evaluated using the Bland-Altman method. Results The mean age was 36.0 +/- 25.6 years (range: 5 to 85 years). The mean axial length was 24.42 +/- 0.13 mm for SS-OCT and 24.45 +/- 0.14 mm for PCI. The mean corneal curvature was significantly different between the two biometry in flat K (K1) but not in steep K (K2). The limit of agreement was -0.15 to 0.21 in the axial length, -1.18 to 0.83 in K1, and -1.06 to 0.95 in K2. All above ocular biometric measurements between SS-OCT and PCI correlated significantly (Pearson's correlation, p<0.001). Conclusions The axial length measured using SS-OCT is useful in clinical practice. It shows a good correlation and agreement with that measured using PCI. However, the axial length and corneal curvature measured using SS-OCT cannot be used interchangeably with that measured using PCI in clinical practice.
引用
收藏
页数:11
相关论文
共 22 条
[1]   Pursuing perfection in intraocular lens calculations IV. Rethinking astigmatism analysis for intraocular lens-based surgery: Suggested terminology, analysis, and standards for outcome reports [J].
Abulafia, Adi ;
Koch, Douglas D. ;
Holladay, Jack T. ;
Wang, Li ;
Hill, Warren .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2018, 44 (10) :1169-1174
[2]   Accuracy of swept-source optical coherence tomography based biometry for intraocular lens power calculation: a retrospective cross-sectional study [J].
An, Youngju ;
Kang, Eun-Kyoung ;
Kim, Hyojin ;
Kang, Min-Ji ;
Byun, Yong-Soo ;
Joo, Choun-Ki .
BMC OPHTHALMOLOGY, 2019, 19 (1)
[3]   COMPARING METHODS OF MEASUREMENT - WHY PLOTTING DIFFERENCE AGAINST STANDARD METHOD IS MISLEADING [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1995, 346 (8982) :1085-1087
[4]   Accuracy and reproducibility of biometry using partial coherence interferometry [J].
Connors, R ;
Boseman, P ;
Olson, RJ .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :235-238
[5]   Comparison of OA-2000 and IOL Master 500 using in cataract patients with high myopia [J].
Du, Ya-Li ;
Wang, Geng ;
Huang, Hui-Chun ;
Lin, Li-Yu ;
Jin, Chuang ;
Liu, Li-Fang ;
Liu, Xiu-Ru ;
Zhang, Ming-Zhi .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2019, 12 (05) :844-847
[6]   Effect of axial length and keratometry measurement error on intraocular lens implant power prediction formulas in pediatric patients [J].
Eibschitz-Tsimhoni, Maya ;
Tsimhoni, Omer ;
Archer, Steven M. ;
Del Monte, Monte A. .
JOURNAL OF AAPOS, 2008, 12 (02) :173-176
[7]   Comparison of 2 swept-source optical coherence tomography-based biometry devices [J].
Fisus, Andreea D. ;
Hirnschall, Nino D. ;
Findl, Oliver .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (01) :87-92
[8]   Comparison of a new biometer using swept-source optical coherence tomography and a conventional biometer using partial coherence interferometry [J].
Higashiyama, Tomoaki ;
Mori, Hazuki ;
Nakajima, Fumi ;
Ohji, Masahito .
PLOS ONE, 2018, 13 (04)
[9]   Comparison of a new optical biometer using swept-source optical coherence tomography and a biometer using optical low-coherence reflectometry [J].
Hoffer, Kenneth J. ;
Hoffmann, Peter C. ;
Savini, Giacomo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (08) :1165-1172
[10]   Global Prevalence of Myopia and High Myopia and Temporal Trends from 2000 through 2050 [J].
Holden, Brien A. ;
Fricke, Timothy R. ;
Wilson, David A. ;
Jong, Monica ;
Naidoo, Kovin S. ;
Sankaridurg, Padmaja ;
Wong, Tien Y. ;
Naduvilath, Thomas J. ;
Resnikoff, Serge .
OPHTHALMOLOGY, 2016, 123 (05) :1036-1042