Off-design performance comparative analysis of a transcritical CO2 power cycle using a radial turbine by different operation methods

被引:28
作者
Du, Yang [1 ]
Chen, Haichao [1 ]
Hao, Muting [2 ]
Qiang, Xiongchao [1 ]
Wang, Jiangfeng [1 ]
Dai, Yiping [1 ]
机构
[1] Xi An Jiao Tong Univ, Inst Turbomachinery, Stare Key Lab Multiphase Flow Power Engn, Sch Energy & Power Engn, Xian 710049, Shaanxi, Peoples R China
[2] Univ Oxford, Oxford Thermofluids Inst, Dept Engn Sci, Parks Rd, Oxford OX1 3PJ, England
关键词
Transcritical CO2 power cycle; Off-design performance; Operation method; Radial turbine; Adjustable stator blades; ORGANIC RANKINE-CYCLE; LOW-GRADE HEAT; WASTE HEAT; THERMODYNAMIC ANALYSIS; ENERGY; ENGINE; OPTIMIZATION; SYSTEM; CONVERSION; CTRC;
D O I
10.1016/j.enconman.2018.05.036
中图分类号
O414.1 [热力学];
学科分类号
摘要
Comparative analysis on off-design performance of a transcritical CO2 (tCO(2)) power cycle by different operation methods is conducted in this paper. The studied cycle is based on printed circuit heat exchangers (PCHEs) and a radial turbine with adjustable stator blades. A novel method for the optimal operation is proposed to obtain its maximal net power at given parameters of geothermal water. The optimal operation method is found by adjusting control variables including the evaporating pressure and the outlet angle of the adjustable stator. This paper compares the constant pressure operation method based on the adjustable stator, the optimal operation method, and the sliding pressure operation method. The results indicate that the ranges of control variables are narrower by the optimal operation method than by the sliding pressure operation method or by the constant pressure operation method. When the inlet temperature of geothermal water is fixed at the design value (125 degrees C), the method for optimal operation could generate 15.07% at most more net power than the sliding pressure operation method does and 3.49% more net power than the constant pressure operation method does at studied mass flow rate ratios of geothermal water. The increase of the net power per unit inlet temperature of geothermal water results in an increase of 1.19-1.98% by the optimal operation method compared with the net power at the design point.
引用
收藏
页码:529 / 544
页数:16
相关论文
共 41 条
[1]   Thermo-economic analysis and multi-objective optimization of a transcritical CO2 power cycle driven by solar energy and LNG cold recovery [J].
Ahmadi, Mohammad H. ;
Mehrpooya, Mehdi ;
Abbasi, Sara ;
Pourfayaz, Fathollah ;
Bruno, Joan Carles .
THERMAL SCIENCE AND ENGINEERING PROGRESS, 2017, 4 :185-196
[2]   Thermodynamic and exergy analysis and optimization of a transcritical CO2 power cycle driven by geothermal energy with liquefied natural gas as its heat sink [J].
Ahmadi, Mohammad H. ;
Mehrpooya, Mehdi ;
Pourfayaz, Fathollah .
APPLIED THERMAL ENGINEERING, 2016, 109 :640-652
[3]  
Aungier R.H., 2006, PRELIMINARY AERODYNA
[4]   Comparative analysis on off-design performance of a gas turbine and ORC combined cycle under different operation approaches [J].
Cao, Yue ;
Dai, Yiping .
ENERGY CONVERSION AND MANAGEMENT, 2017, 135 :84-100
[5]   Parametric study and optimization of a transcritical power cycle using a low temperature source [J].
Cayer, Emmanuel ;
Galanis, Nicolas ;
Nesreddine, Hakim .
APPLIED ENERGY, 2010, 87 (04) :1349-1357
[6]   Analysis of a carbon dioxide transcritical power cycle using a low temperature source [J].
Cayer, Emmanuel ;
Galanis, Nicolas ;
Desilets, Martin ;
Nesreddine, Hakim ;
Roy, Philippe .
APPLIED ENERGY, 2009, 86 (7-8) :1055-1063
[7]   A review of thermodynamic cycles and working fluids for the conversion of low-grade heat [J].
Chen, Huijuan ;
Goswami, D. Yogi ;
Stefanakos, Elias K. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2010, 14 (09) :3059-3067
[8]   A comparative study of the carbon dioxide transcritical power cycle compared with an organic rankine cycle with R123 as working fluid in waste heat recovery [J].
Chen, Y. ;
Lundqvist, P. ;
Johansson, A. ;
Platell, P. .
APPLIED THERMAL ENGINEERING, 2006, 26 (17-18) :2142-2147
[9]  
Dostal V., 2004, MASSACHUSETTS I TECH, V154, P265
[10]   Off-design performance analysis of a combined cooling and power system driven by low-grade heat source [J].
Du, Yang ;
Han, Pengfei ;
Qiang, Xiongchao ;
Hao, Muting ;
Long, Ying ;
Zhao, Pan ;
Dai, Yiping .
ENERGY CONVERSION AND MANAGEMENT, 2018, 159 :327-341