Which Factors Determine the Wear Rate of Large-Diameter Metal-on-Metal Hip Replacements?

被引:57
作者
Hart, A. J.
Muirhead-Allwood, S.
Porter, M.
Matthies, A.
Ilo, K.
Maggiore, P.
Underwood, R.
Cann, P.
Cobb, J.
Skinner, J. A.
机构
[1] Univ London Imperial Coll Sci Technol & Med, London Implant Retrieval Ctr, London SW7 2AZ, England
[2] Royal Natl Orthopaed Hosp NHS Trust, Stanmore, Middx, England
关键词
IN-VIVO WEAR; RESURFACING ARTHROPLASTY; ACETABULAR COMPONENT; RETRIEVAL ANALYSIS; IMPLANT FAILURE; BEARINGS; CUP; INCLINATION; ORIENTATION; PERFORMANCE;
D O I
10.2106/JBJS.J.01447
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Determining the relationship between clinical factors and engineering analysis of retrieved hip implants can help our understanding of the mechanism of device failure. This is particularly important for metal-on-metal hip arthroplasties because the most common cause of failure is unexplained. We sought to understand the variation in wear rates in a large series of retrieved metal-on-metal hip arthroplasty components. Methods: We prospectively recorded preoperative, intraoperative, and postoperative data to study the effect on both head and cup wear rates of the following variables: patient sex, cause of failure, manufacturer type, resurfacing or modular design, blood cobalt and chromium levels, edge-loading, femoral head size, and cup inclination angle. We analyzed 276 components (138 femoral head and acetabular cup couples) retrieved from failed metal-on-metal hip replacements. Results: We found a high rate of edge-loading (64%), but only forty-three (31%) of 138 hips had a cup inclination angle of >55 degrees. Multivariate analysis showed that the most important factor responsible for the variation in wear rate was the presence or absence of edge-loading, even when adjusted for cup inclination angle. Strong positive correlations were found between acetabular cup and femoral head wear rates and between wear rates and both blood cobalt and chromium ion levels. Conclusions: Multivariate analysis of nine factors found that edge-loading was the most important predictor of wear rate and occurred in two-thirds of failed metal-on-metal hip replacements. The majority did not have excessive cup inclination angles: 68% had an inclination angle of <= 55 degrees. This finding, together with the relatively low median wear rate of the components in our study, suggests that cup position and/or wear rate may not be the only outcome related to failure of metal-on-metal hip replacements.
引用
收藏
页码:678 / 685
页数:8
相关论文
共 43 条
[1]   The Combined Anteversion Technique for Acetabular Component Anteversion [J].
Amuwa, Christopher ;
Dorr, Lawrence D. .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :1068-1070
[2]   Influence of cup orientation on the wear performance of metal-on-metal hip replacements [J].
Angadji, A. ;
Royle, M. ;
Collins, S. N. ;
Shelton, J. C. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2009, 223 (H4) :449-457
[3]   Metal-on-metal bearing in hip prosthesis generates 100-fold less wear debris than metal-on-polyethylene [J].
Anissian, HL ;
Stark, A ;
Gustafson, A ;
Good, V ;
Clarke, IC .
ACTA ORTHOPAEDICA SCANDINAVICA, 1999, 70 (06) :578-582
[4]  
Australian Orthopaedic Association National Joint Replacement Registry, 2009, ANN REPORT
[5]   Metal-on-metal hip simulator study of increased wear particle surface area due to 'severe' patient activity [J].
Bowsher, JG ;
Hussain, A ;
Williams, PA ;
Shelton, JC .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2006, 220 (H2) :279-287
[6]   Correlation between inclination of the acetabular component and metal ion levels in metal-on-metal hip resurfacing replacement [J].
De Haan, R. ;
Pattyn, C. ;
Gill, H. S. ;
Murray, D. W. ;
Campbell, P. A. ;
De Smet, K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1291-1297
[7]   Metal Ion Measurement as a Diagnostic Tool to Identify Problems with Metal-on-Metal Hip Resurfacing [J].
de Smet, K. ;
de Haan, R. ;
Calistri, A. ;
Campbell, P. A. ;
Ebramzadeh, E. ;
Pattyn, C. ;
Gill, H. S. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A :202-208
[8]   Early failure of the Ultima metal-on-metal total hip replacement in the presence of normal plain radiographs [J].
Donell, S. T. ;
Darrah, C. ;
Nolan, J. F. ;
Wimhurst, J. ;
Toms, A. ;
Barker, T. H. W. ;
Case, C. P. ;
Tucker, J. K. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (11) :1501-1508
[9]   The Metasul metal-on-metal articulation in primary total hip replacement: Clinical and radiological results at ten years [J].
Eswaramoorthy, V. ;
Moonot, P. ;
Kalairajah, Y. ;
Biant, L. C. ;
Field, R. E. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (10) :1278-1283
[10]  
Firkins PJ, 2001, BIO-MED MATER ENG, V11, P143