Improved immobilization of DNA to graphite surfaces, using amino acid modified clays

被引:24
作者
Ensafi, Ali A. [1 ]
Heydari-Bafrooei, Esmaeil [1 ]
Dinari, Mohammad [1 ]
Mallakpour, S. [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 8415683111, Iran
关键词
COVALENT IMMOBILIZATION; SELECTIVE DETECTION; CARBON; OLIGONUCLEOTIDES; BIOSENSOR; ELECTRODES; IMMUNOSENSOR; FABRICATION; ADSORPTION; PEPTIDE;
D O I
10.1039/c3tb21827a
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
Assessment of the interaction of small molecules with DNA, hybridization assays for DNA sequence analysis and diagnostics and the investigation of DNA damage involves the immobilization of an array of oligonucleotides onto a solid substrate. Herein, a new nano sized DNA-based biosensor containing valine (Val) amino acid organo-modified Cloisite Na+ as a new bionanohybrid film for the immobilization of DNA was developed. The Cloisite-Val organoclay was synthesized by a cation-exchange method, which involves the displacement of the sodium cations of Cloisite Na+ with the ammonium ions of the Val-amino acid. The synthesized materials were characterized with different methods such as FT-IR spectroscopy, TEM, SEM, XRD and electrochemical impedance spectroscopy (EIS). The nanostructured film was deposited at the surface of a working graphite electrode and utilized for the surface modification with double-stranded DNA. It was found that the electrode modification with DNA and Cloisite-Val leads to an enhanced sensitivity in the DNA voltammetric detection compared with other modified electrodes that were used for this work. The efficiency of DNA immobilization was followed by means of EIS and voltammetry. Immobilization is much more rapid when using the Cloisite-Val modified graphite support than when employing conventional supports. The stability of the immobilized DNA over several days has been found to be much higher when using the new support than in preparations using conventional ones.
引用
收藏
页码:3022 / 3028
页数:7
相关论文
共 40 条
[11]   Different interaction of codeine and morphine with DNA: A concept for simultaneous determination [J].
Ensafi, Ali A. ;
Heydari-Bafrooei, E. ;
Rezaei, B. .
BIOSENSORS & BIOELECTRONICS, 2013, 41 :627-633
[12]   DNA-functionalized biosensor for riboflavin based electrochemical interaction on pretreated pencil graphite electrode [J].
Ensafi, Ali A. ;
Heydari-Bafrooei, Esmaeil ;
Amini, Maryam .
BIOSENSORS & BIOELECTRONICS, 2012, 31 (01) :376-381
[13]   Effects of elastin-derived peptide on Achilles' tendon healing: An experimental study [J].
Gigante, A ;
Chillemi, C ;
Bevilacqua, C ;
Greco, F .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2003, 14 (08) :717-720
[14]   Fabrication and characterization of DNA-thionine-carbon nanotube nanocomposites [J].
Gong, Meijuan ;
Han, Tao ;
Cai, Chenxin ;
Lu, Tianhong ;
Du, Jiangyan .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 623 (01) :8-14
[15]   Layer-by-layer fabrication and characterization of DNA-wrapped single-walled carbon nanotube particles [J].
He, PG ;
Bayachou, M .
LANGMUIR, 2005, 21 (13) :6086-6092
[16]   Layer-by-layer self-assembly and electrochemistry: Applications in biosensing and bioelectronics [J].
Iost, Rodrigo M. ;
Crespilho, Frank N. .
BIOSENSORS & BIOELECTRONICS, 2012, 31 (01) :1-10
[17]   Immobilization of DNA on carbon fiber microelectrodes by using overoxidized polypyrrole template for selective detection of dopamine and epinephrine in the presence of high concentrations of ascorbic acid and uric acid [J].
Jiang, XH ;
Lin, XQ .
ANALYST, 2005, 130 (03) :391-396
[18]   A label-free electrochemical biosensor for highly sensitive and selective detection of DNA via a dual-amplified strategy [J].
Kong, Rong-Mei ;
Song, Zhi-Ling ;
Meng, Hong-Min ;
Zhang, Xiao-Bing ;
Shen, Guo-Li ;
Yu, Ru-Qin .
BIOSENSORS & BIOELECTRONICS, 2014, 54 :442-447
[19]   An amperometric immunosensor with a DNA polyion complex membrane/gold nanoparticles-backbone for antibody immobilisation [J].
Li, Na ;
Zhao, Hongwen ;
Yuan, Ruo ;
Peng, Kanfu ;
Chai, Yaqin .
ELECTROCHIMICA ACTA, 2008, 54 (02) :235-241
[20]   MALDI on a chip: Analysis of arrays of low femtomole to subfemtomole quantities of synthetic oligonucleotides and DNA diagnostic products dispensed by a piezoelectric pipet [J].
Little, DP ;
Cornish, TJ ;
ODonnell, MJ ;
Braun, A ;
Cotter, RJ ;
Koster, H .
ANALYTICAL CHEMISTRY, 1997, 69 (22) :4540-4546