Native Protein Separation by Isoelectric Focusing and Blue Gel Electrophoresis-Coupled Two-Dimensional Microfluidic Chip Electrophoresis

被引:4
作者
Hou, Ni [1 ]
Chen, Yu [2 ]
Yu, Shiyong [1 ]
Quan, Zongliang [1 ]
Pan, Chenhua [1 ]
Deng, Yulin [1 ]
Geng, Lina [1 ]
机构
[1] Beijing Inst Technol, Sch Life Sci & Technol, Beijing 100081, Peoples R China
[2] Shaanxi Canc Hosp, Xian 710061, Peoples R China
基金
中国国家自然科学基金;
关键词
Two-dimensional microfluidic chip electrophoresis; Blue gel electrophoresis; Isoelectric focusing; Native protein separation; Peak capacity evaluation; CAPILLARY-ELECTROPHORESIS; INTEGRATION; DEVICE;
D O I
10.1007/s10337-014-2728-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of microfluidic chip-based two-dimensional separation holds great promise in the proteomics field, given its portability, simplicity, speed, efficiency, and throughput. However, inclusion of sodium dodecyl sulfate, reported to be necessary for increasing protein-resolving capability, was also accompanied by the loss of both protein conformation and biological function. Here, we describe separation of native proteins by introducing blue native gel electrophoresis into isoelectric focusing and gel electrophoresis (IEF/CGE)-coupled protein two-dimensional microfluidic chip electrophoresis. After assessing the influence of various experimental conditions, the best separation ability and reproducibility of blue native IEF/CGE (IEF/BN-CGE) chip electrophoresis achieved until now were demonstrated no matter whether with a simple simulated mixture or with a complex mixture of total Escherichia coli proteins. Finally, instead of theoretical calculations, the image analysis technique was also used for the first time to quantitatively evaluate the actual peak capacities of chip electrophoresis. According to the number of features abstracted in the electrophoresis patterns, the superiority of the IEF/BN-CGE two-dimensional microfluidic chip electrophoresis was then exhibited quantitatively. The high native protein separation performance makes this established chip electrophoresis method possible for further application in widely needed drug screening, analysis of bio-molecular function, and assays of protein-protein interactions.
引用
收藏
页码:1339 / 1346
页数:8
相关论文
共 21 条
[1]  
[Anonymous], UNIFIED SEPARATION S
[2]   Two-dimensional protein separation in microfluidic devices [J].
Chen, Hong ;
Fan, Z. Hugh .
ELECTROPHORESIS, 2009, 30 (05) :758-765
[3]   A prototype two-dimensional capillary electrophoresis system fabricated in poly(dimethylsiloxane) [J].
Chen, XX ;
Wu, HK ;
Mao, CD ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2002, 74 (08) :1772-1778
[4]   Miniaturized two-dimensional capillary electrophoresis on a microchip for analysis of the tryptic digest of proteins [J].
Cong, Yongzheng ;
Zhang, Lihua ;
Tao, Dingyin ;
Liang, Yu ;
Zhang, Weibing ;
Zhang, Yukui .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (03) :588-594
[5]   Device fabrication and integration with photodefinable microvalves for protein separation [J].
Das, Champak ;
Fredrickson, Carl K. ;
Xia, Zheng ;
Fan, Z. Hugh .
SENSORS AND ACTUATORS A-PHYSICAL, 2007, 134 (01) :271-277
[6]   Integration of isoelectric focusing with multi-channel gel electrophoresis by using microfluidic pseudo-valves [J].
Das, Champak ;
Zhang, Jiyou ;
Denslow, Nancy D. ;
Fan, Z. Hugh .
LAB ON A CHIP, 2007, 7 (12) :1806-1812
[7]   Microfabricated two-dimensional electrophoresis device for differential protein expression profiling [J].
Emrich, Charles A. ;
Medintz, Igor L. ;
Chu, Wai K. ;
Mathies, Richard A. .
ANALYTICAL CHEMISTRY, 2007, 79 (19) :7360-7366
[8]   Native Capillary Isoelectric Focusing for the Separation of Protein Complex Isoforms and Subcomplexes [J].
Fonslow, Bryan R. ;
Kang, Seong A. ;
Gestaut, Daniel R. ;
Graczyk, Beth ;
Davis, Trisha N. ;
Sabatini, David M. ;
Yates, John R., III .
ANALYTICAL CHEMISTRY, 2010, 82 (15) :6643-6651
[9]  
Frank K, 2006, ELECTROPHORESIS, V27, P2759
[10]   CONCEPTS AND COMPARISONS IN MULTIDIMENSIONAL SEPARATION [J].
GIDDINGS, JC .
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1987, 10 (05) :319-323