Care Bundle Approach to Minimizing Infection Rates after Neurosurgical Implants for Neuromodulation: A Single-Surgeon Experience

被引:29
作者
Arocho-Quinones, Elsa V. [1 ,2 ]
Huang, Chiang-Ching [4 ]
Ward, Barney D. [3 ]
Pahapill, Peter A. [1 ,2 ]
机构
[1] US Dept Vet Affairs, Dept Neurosurg, Med Ctr, Milwaukee, WI 53223 USA
[2] Med Coll Wisconsin, Dept Neurosurg, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[4] Univ Wisconsin, Joseph J Zilber Sch Publ Hlth, Milwaukee, WI 53201 USA
关键词
Bundle; Checklists; Deep brain stimulation; Intrathecal pumps; Spinal cord stimulation; Surgical implant; Surgical site infection; SURGICAL-SITE INFECTIONS; BRAIN-STIMULATION SURGERY; INTRATHECAL BACLOFEN PUMP; RISK-FACTORS; GENERATOR REPLACEMENT; SILK; COMPLICATIONS; PREVENTION; SYSTEMS; REDUCE;
D O I
10.1016/j.wneu.2019.04.003
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
INTRODUCTION: Implant-related infections carry a high morbidity. Infectious rates for neuromodulation implants range from 1% to 9% for deep brain stimulation (DBS), 0% to 10% for spinal cord stimulation (SCS) systems, and 3% to 15% for intrathecal (IT) pump systems. Meanwhile, studies of care bundles report infection rate reduction to 1.0% for SCS and 0.3% for cardiac implants. Herein, we evaluate the effectiveness of an infection prevention bundle (IPB) in minimizing infections after surgeries for neuromodulation implants. METHODS: An IPB focused on preoperative checklists, screening questionnaires, methicillin-resistant and methicillin-sensitive Staphylococcus aureus decolonization, weight-based antibiotic prophylaxis, strict draping and surgical techniques, and wound care education was implemented in our functional neurosurgery division in April 2015. We retrospectively reviewed all surgeries for implantation or replacement of SCS, DBS, and IT pump system components from March 2013 to October 2017. The patients were divided into pre-IPB and post-IPB groups. All procedures were performed by a single surgeon. Each surgical site was considered a unique surgical case. Infection rates were calculated for pre-IPB and post-IPB groups. RESULTS: A total of 688 patients underwent 1161 unique surgical procedures (222 DBS electrodes, 419 IPG, 203 SCS, 317 IT pumps) during the study period. There were 546 pre-IPB and 615 post-IPB surgical procedures. The pre-IPB infection rates were 0%, 1.3%, and 8.7% for SCS, DBS, and IT pumps, respectively. The post-IPB infection rates were 0%, 0.3%, and 1.8% for SCS, DBS, and IT pumps, respectively. CONCLUSIONS: Implementation of a standardized IPB approach reduced the number of infections for all neuromodulation implants studied. This approach can be adopted within any specialty to potentially decrease the incidence of implant-related infections.
引用
收藏
页码:E87 / E97
页数:11
相关论文
共 27 条
[21]   The Adjunctive Use of Vancomycin Powder Appears Safe and May Reduce the Incidence of Surgical-Site Infections After Deep Brain Stimulation Surgery [J].
Rasouli, Jonathan J. ;
Kopell, Brian Harris .
WORLD NEUROSURGERY, 2016, 95 :9-13
[22]   The Influence of Perioperative Risk Factors and Therapeutic Interventions on Infection Rates After Spine Surgery A Systematic Review [J].
Schuster, James M. ;
Rechtine, Glenn ;
Norvell, Daniel C. ;
Dettori, Joseph R. .
SPINE, 2010, 35 (09) :S125-S137
[23]   Association of a Bundled Intervention With Surgical Site Infections Among Patients Undergoing Cardiac, Hip, or Knee Surgery [J].
Schweizer, Marin L. ;
Chiang, Hsiu-Yin ;
Septimus, Edward ;
Moody, Julia ;
Braun, Barbara ;
Hafner, Joanne ;
Ward, Melissa A. ;
Hickok, Jason ;
Perencevich, Eli N. ;
Diekema, Daniel J. ;
Richards, Cheryl L. ;
Cavanaugh, Joseph E. ;
Perlin, Jonathan B. ;
Herwaldt, Loreen A. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2015, 313 (21) :2162-2171
[24]   Tensile strength and host response towards silk and type I polypropylene implants used for augmentation of fascial repair in a rat model [J].
Spelzini, Federico ;
Konstantinovic, Maja L. ;
Guelinckx, Isabelle ;
Verbist, Godelieve ;
Verbeken, Erik ;
De Ridder, Dirk ;
Deprest, Jan .
GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2007, 63 (03) :155-162
[25]   Rate of Complications Among the Recipients of Intrathecal Baclofen Pump in Japan: A Multicenter Study [J].
Taira, Takaomi ;
Ueta, Takayoshi ;
Katayama, Yoichi ;
Kimizuka, Mamori ;
Nemoto, Akinobu ;
Mizusawa, Hidehiro ;
Liu, Meigen ;
Koito, Motonao ;
Hiro, Yuko ;
Tanabe, Hirokazu .
NEUROMODULATION, 2013, 16 (03) :266-272
[26]   Increasing Infection Rate in Multiple Implanted Pulse Generator Changes in Movement Disorder Patients Treated with Deep Brain Stimulation [J].
Thrane, Jens F. ;
Sunde, Niels A. ;
Bergholt, Bo ;
Rosendal, Frederikke .
STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2014, 92 (06) :360-364
[27]   A Multidisciplinary Infection Control Bundle to Reduce the Number of Spinal Cord Stimulator Infections [J].
Yusuf, Erlangga ;
Bamps, Sven ;
Thuer, Benedicte ;
Mattheussen, Jan ;
Ursi, Jean-Paul ;
Del Biondo, Elke ;
de Smedt, Kris ;
Van Paesschen, Raf ;
Berghmans, Dirk ;
Hofkens, Kaat ;
Van Schaeren, Jef ;
van Havenbergh, Tony ;
Van Herendael, Bruno .
NEUROMODULATION, 2017, 20 (06) :563-566