Comparison of commercial thermoluminescent readers regarding high-dose high-temperature measurements

被引:45
作者
Bilski, P. [1 ]
Gieszczyk, W. [1 ]
Obryk, B. [1 ]
Hodyr, K. [2 ]
机构
[1] Polish Acad Sci, Inst Nucl Phys, Krakow, Poland
[2] Lodz Univ Technol, Inst Appl Radiat Chem, Lodz, Poland
关键词
Comparison; TLD readers; High doses; High temperatures; LiF:Mg; Cu; P; N TL DETECTORS; EMISSION; RANGE;
D O I
10.1016/j.radmeas.2014.04.020
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Three different thermoluminescent measuring systems have been compared with respect to the differences in temperature profiles, spectral sensitivities, as well as characteristics for high intensities of TL light. The comparison was performed using the Harshaw 3500, Rise, DA-20 and RA'94 TLD readers. The instruments were tested for the readouts of highly irradiated LiF:Mg,Cu,P (MCP) TL detectors, which require readout up to 550 degrees C, in case of doses exceeding 1 kGy. It was found that the Harshaw 3500 can be used, without any additional light attenuation, for the measurements of MCP detectors exposed to doses up to about 5 Gy. For the other two readers the upper dose limit is about 10 times lower. It was also found that the Harshaw 3500 shows the best thermal stability considering the peak maximum position. For the ultra-high doses the differences in the spectral characteristics of the applied optical filters and photomultipliers, in conjunction with an evolution of the MCP TL emission spectrum with increasing dose, significantly influence the shape of TL glow curves measured with the DA-20 reader. The detailed characteristic of the compared TLD readers at high-dose high-temperature range is discussed. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:8 / 13
页数:6
相关论文
共 10 条
[1]   Characteristics of LiF:Mg,Cu,P thermoluminescence at ultra-high dose range [J].
Bilski, P. ;
Obryk, B. ;
Olko, P. ;
Mandowska, E. ;
Mandowski, A. ;
Kim, J. L. .
RADIATION MEASUREMENTS, 2008, 43 (2-6) :315-318
[2]   Advances in luminescence instrument systems [J].
Botter-Jensen, L ;
Bulur, E ;
Duller, GAT ;
Murray, AS .
RADIATION MEASUREMENTS, 2000, 32 (5-6) :523-528
[3]   Measurements of high-temperature emission spectra of highly irradiated LiF:Mg,Cu,P (MCP-N) TL detectors [J].
Gieszczyk, W. ;
Bilski, P. ;
Obryk, B. ;
Olko, P. ;
Bos, A. J. J. .
RADIATION MEASUREMENTS, 2013, 56 :183-186
[4]   Spectral characteristic of high-dose high-temperature emission from LiF:Mg,Cu,P (MCP-N) TL detectors [J].
Gieszczyk, W. ;
Bilski, P. ;
Obryk, B. ;
Olko, P. ;
Bos, A. J. J. .
RADIATION MEASUREMENTS, 2013, 53-54 :22-30
[5]   Spectrally resolved thermoluminescence of highly irradiated LiF:Mg,Cu,P detectors [J].
Mandowska, E. ;
Bilski, P. ;
Obryk, B. ;
Mandowski, A. ;
Olko, P. ;
Kim, J. .
RADIATION MEASUREMENTS, 2010, 45 (3-6) :579-582
[6]   Response of various types of lithium fluoride MCP detectors to high and ultra-high thermal neutron doses [J].
Obryk, B. ;
Glaser, M. ;
Mandic, I. ;
Bilski, P. ;
Olko, P. ;
Sas-Bieniarz, A. .
RADIATION MEASUREMENTS, 2011, 46 (12) :1882-1885
[7]   The response of TL lithium fluoride detectors to 24 GeV/c protons for doses ranging up to 1 MGy [J].
Obryk, B. ;
Bilski, P. ;
Glaser, M. ;
Fuerstner, M. ;
Budzanowski, M. ;
Olko, P. ;
Pajor, A. .
RADIATION MEASUREMENTS, 2010, 45 (3-6) :643-645
[8]   From nGy to MGy - new dosimetry with LiF: Mg,Cu,P thermoluminescence detectors [J].
Obryk, Barbara .
XXXV BRAZILIAN WORKSHOP ON NUCLEAR PHYSICS, 2013, 1529 :22-29
[9]   METHOD OF THERMOLUMINESCENT MEASUREMENT OF RADIATION DOSES FROM MICROGRAYS UP TO A MEGAGRAY WITH A SINGLE LiF:Mg,Cu,P DETECTOR [J].
Obryk, Barbara ;
Bilski, Pawel ;
Olko, Pawel .
RADIATION PROTECTION DOSIMETRY, 2011, 144 (1-4) :543-547
[10]   Development of a Method for Passive Measurement of Radiation Doses at Ultra-High Dose Range [J].
Obryk, Barbara ;
Bilski, Pawel ;
Budzanowski, Maciej ;
Fuerstner, Markus ;
Glaser, Maurice ;
Ilgner, Christoph J. ;
Olko, Pawel ;
Pajor, Anna ;
Stuglik, Zofia .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (06) :3759-3763