Estimation of neonatal body composition: Isotope dilution versus total-body electrical conductivity

被引:8
作者
Hashimoto, K
Wong, WW
Thomas, AJ
Uvena-Celebrezze, J
Huston-Pressley, L
Amini, SB
Catalano, PM
机构
[1] Case Western Reserve Univ, Metrohlth Med Ctr, Dept Reprod Biol, Cleveland, OH 44109 USA
[2] USDA ARS, Childrens Nutr Res Ctr, Houston, TX USA
[3] Texas Childrens Hosp, Baylor Coll Med, Dept Pediat, Houston, TX 77030 USA
来源
BIOLOGY OF THE NEONATE | 2002年 / 81卷 / 03期
关键词
neonatal body composition; body fat; total body water; isotope dilution; total-body electrical conductivity;
D O I
10.1159/000051530
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
The objective of the study is to evaluate neonatal body composition determined by the isotope dilution method compared with the total-body electrical conductivity (TOBEC) method. An oral dose of O-18- and H-2-labeled water was given to 40 healthy term newborns, and 26 infants successfully completed the protocol. The isotope concentrations in urine samples were measured by gas-isotope ratio mass spectrometry. Fat and percent body fat (%F) estimated by isotope dilution were correlated with fat and %F estimated. Total body water measured by isotope dilution of O-18 and H-2 was 2.44 +/- 0.36 and 2.49 +/- 0.35 kg, respectively (p < 0.001). Fat and %F estimated by O-18, H-2, and TOBEC were 0.48 +/- 0.20 kg and 13.7 +/- 5.1%, 0.48 +/- 0.19 kg and 13.7 +/- 4.6%, and 0.38 +/- 0.21 kg and 10.9 +/- 5.0%, respectively. Neither fat nor %F estimates by isotope dilution showed good correlation with the TOBEC estimates (r = 0.22-0.57). Because of the wide variation of water content in individuals, the isotope dilution method may not be the optimal way of assessing body composition, and specifically body fat, in newborns.
引用
收藏
页码:170 / 175
页数:6
相关论文
共 50 条
[41]   Body composition in adults with cerebral palsy by dual-energy X-ray absorptiometry, bioelectrical impedance analysis, and skinfold anthropometry compared with the O-18 isotope-dilution technique [J].
Hildreth, HG ;
Johnson, RK ;
Goran, MI ;
Contompasis, SH .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1997, 66 (06) :1436-1442
[42]   Total body electrical conductivity (TOBEC) measurements in Mongolian gerbils (Meriones unguiculatus) and golden hamsters (Mesocricetus auratus) [J].
Weinandy, R ;
Gattermann, R .
JOURNAL OF EXPERIMENTAL ANIMAL SCIENCE, 2002, 42 (01) :21-30
[43]   A simple prediction of total body water to aid quality control in isotope dilution studies in subjects 3-87 years of age [J].
Slater, C ;
Preston, T .
ISOTOPES IN ENVIRONMENTAL AND HEALTH STUDIES, 2005, 41 (02) :99-107
[44]   Changes in total body fat during the human reproductive cycle as assessed by magnetic resonance imaging, body water dilution, and skinfold thickness: a comparison of methods [J].
Sohlstrom, A ;
Forsum, E .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1997, 66 (06) :1315-1322
[45]   Validation of estimates of total body water in pediatric dialysis patients by deuterium dilution [J].
Mendley, SR ;
Majkowski, NL ;
Schoeller, DA .
KIDNEY INTERNATIONAL, 2005, 67 (05) :2056-2062
[46]   Total Body Water (TBW) for Body Composition Assessment in Young Adult Females from Colombia [J].
Gonzalez-Correa, Clara H. ;
Caicedo-Eraso, Julio C. ;
Gallagher, Dympna .
II LATIN AMERICAN CONFERENCE ON BIOIMPEDANCE, 2016, 54 :40-43
[47]   Body composition by dilution of deuterium oxide in Mexican children with lymphoma and solid tumors [J].
Barbosa-Cortes, Lourdes ;
Tapia-Rojas, Marisa ;
Lopez-Aguilar, Enrique ;
Mejia-Arangure, Juan Manuel ;
Rivera-Marquez, Hugo .
NUTRITION, 2007, 23 (10) :739-744
[48]   EVALUATION OF MULTIFREQUENCY BIOIMPEDANCE ANALYSIS FOR THE ASSESSMENT OF EXTRACELLULAR AND TOTAL-BODY WATER IN SURGICAL PATIENTS [J].
HANNAN, WJ ;
COWEN, SJ ;
FEARON, KCH ;
PLESTER, CE ;
FALCONER, JS ;
RICHARDSON, RA .
CLINICAL SCIENCE, 1994, 86 (04) :479-485
[49]   HYPERTENSION PROFILING BY TOTAL-BODY WATER (TBW) DETERMINATIONS IN PATIENTS ON CHRONIC-HEMODIALYSIS [J].
THYLEN, P ;
ERICSSON, F ;
ODARCEDERLOF, I ;
KJELLSTRAND, CM .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1991, 14 (01) :18-22
[50]   Comparison of isotope dilution with bioimpedance spectroscopy and anthropometry for assessment of body composition in asymptornatic HIV-infected and HIV-uninfected breastfeeding mothers [J].
Papathakis, PC ;
Rollins, NC ;
Brown, KH ;
Bennish, ML ;
Van Loan, MD .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2005, 82 (03) :538-546