Overview of Impella and mechanical devices in cardiogenic shock

被引:35
作者
Chera, Hymie Habib [1 ]
Nagar, Menachem [1 ]
Chang, Nai-Lun [1 ]
Morales-Mangual, Carlos [1 ]
Dous, George [1 ]
Marmur, Jonathan D. [1 ]
Ihsan, Muhammad [1 ]
Madaj, Paul [1 ]
Rosen, Yitzhak [1 ]
机构
[1] Suny Downstate Med Ctr, Div Cardiol, 445 Lenox Ave, Brooklyn, NY 11203 USA
关键词
Cardiogenic shock; Mechanical support devices; Impella; mechanical circulatory support; percutaneous ventricular assist device; intra-aortic balloon pump; PERCUTANEOUS CORONARY INTERVENTION; VENTRICULAR ASSIST DEVICES; ACUTE MYOCARDIAL-INFARCTION; INTRAAORTIC BALLOON PUMP; CIRCULATORY SUPPORT; INOTROPIC AGENTS; COUNTERPULSATION; METAANALYSIS; ASSOCIATION; RECOVERY;
D O I
10.1080/17434440.2018.1456334
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Cardiogenic shock (CS) is a life-threatening condition associated with significant morbidity and mortality. The Impella (Abiomed Inc.) is an axial flow pump on a pigtail catheter that is placed across the aortic valve to unload the left ventricle by delivering non-pulsatile blood flow to the ascending aorta. It is used for high-risk percutaneous coronary intervention and CS.Areas covered: Percutaneous mechanical support devices are placed in a minimally invasive manner and provide life-saving assistance. We review Impella and other percutaneous devices such as intra-aortic balloon pump, TandemHeart, and extracorporeal membrane oxygenation (ECMO) and the evidence supporting their use in the setting of CS.Expert commentary: Impella has been proven to be safe and may be superior to other mechanical support devices in CS.
引用
收藏
页码:293 / 299
页数:7
相关论文
共 46 条
[1]  
Alpard S, 2000, CARDIOPULMONARY BYPA, V31, P662
[2]   A Practical Approach to Mechanical Circulatory Support in Patients Undergoing Percutaneous Coronary Intervention An Interventional Perspective [J].
Atkinson, Tamara M. ;
Ohman, E. Magnus ;
O'Neill, William W. ;
Rab, Tanveer ;
Cigarroa, Joaquin E. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2016, 9 (09) :871-883
[3]  
Bansal T, 2014, J CLIN DIAGN RES, V8, pZE21, DOI [10.7860/JCDR/2014/8257.5034, 10.7860/JCDR/2014/8355.4646]
[4]   Effect of Early Initiation of Mechanical Circulatory Support on Survival in Cardiogenic Shock [J].
Basir, Mir B. ;
Schreiber, Theodore L. ;
Grines, Cindy L. ;
Dixon, Simon R. ;
Moses, Jeffrey W. ;
Maini, Brijeshwar S. ;
Khandelwal, Akshay K. ;
Ohman, E. Magnus ;
O'Neill, William W. .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (06) :845-851
[5]   Meta-Analysis of Usefulness of Percutaneous Left Ventricular Assist Devices for High-Risk Percutaneous Coronary Interventions [J].
Briasoulis, Alexandros ;
Telila, Tesfaye ;
Palla, Mohan ;
Mercado, Nestor ;
Kondur, Ashok ;
Grines, Cindy ;
Schreiber, Theodore .
AMERICAN JOURNAL OF CARDIOLOGY, 2016, 118 (03) :369-375
[6]   Impella ventricular support in clinical practice: Collaborative viewpoint from a European expert user group [J].
Burzotta, Francesco ;
Trani, Carlo ;
Doshi, Sagar N. ;
Townend, Jonathan ;
van Geuns, Robert Jan ;
Hunziker, Patrick ;
Schieffer, Bernhard ;
Karatolios, Konstantinos ;
Moller, Jacob Eifer ;
Ribichini, Flavio L. ;
Schaefer, Andreas ;
Henriques, Jose P. S. .
INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 201 :684-691
[7]   Percutaneous left ventricular assist devices vs. intra-aortic balloon pump counterpulsation for treatment of cardiogenic shock: a meta-analysis of controlled trials [J].
Cheng, Jin M. ;
den Uil, Corstiaan A. ;
Hoeks, Sanne E. ;
van der Ent, Martin ;
Jewbali, Lucia S. D. ;
van Domburg, Ron T. ;
Serruys, Patrick W. .
EUROPEAN HEART JOURNAL, 2009, 30 (17) :2102-2108
[8]   Bridge to Recovery Understanding the Disconnect Between Clinical and Biological Outcomes [J].
Drakos, Stavros G. ;
Kfoury, Abdallah G. ;
Stehlik, Josef ;
Selzman, Craig H. ;
Reid, Bruce B. ;
Terrovitis, John V. ;
Nanas, John N. ;
Li, Dean Y. .
CIRCULATION, 2012, 126 (02) :230-241
[9]  
Ergle K, 2016, OCHSNER J, V16, P243
[10]  
Gayat Ettiene MA, 2012, SEVERE HEART FAILURE