Sizing and optimization of on-grid hybrid renewable energy systems considering hydroelectric energy storage

被引:2
|
作者
Yang, Jian [1 ]
Han, Jihua [2 ]
Wu, Tong [3 ]
Zhang, Hao [4 ]
Shang, Lixia [5 ]
机构
[1] Hubei Univ Technol, Hubei Key Lab High Efficiency Utilizat Solar Ener, Wuhan, Peoples R China
[2] State Grid Hubei Jingmen Power Supply Co, Jingmen, Peoples R China
[3] State Grid Liaoning Elect Power Supply Co LTD, Shenyang, Liaoning, Peoples R China
[4] Henan XJ Metering Co LTD, Xuchang, Henan, Peoples R China
[5] State Grid Fushun Elect Power Supply Co, Fushun, Liaoning, Peoples R China
关键词
CO2; emission; energy exchange; energy management; renewable energy; hydroelectric pumped storage; PUMPED-STORAGE; OPTIMAL-DESIGN; POWER; MANAGEMENT; SOLAR; PENETRATION; SIMULATION; GENERATION; FRAMEWORK;
D O I
10.3233/JIFS-192017
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
The economic development of any country is closely linked with the consumption of energy. Therefore, international policies encourage increasing penetration of renewable energy sources (RES) into the electrical grid in order to reduce CO2 emissions and cover ever-increasing demands. However, high variance of RES complicates their integration into power systems and complicates their transition from central to distributed energy sources. On the other hand, increasing the penetration of RES in electrical networks stimulates the demand for large capacity for energy storage. This paper presents a new approach to optimize the size of on-grid renewable energy systems integrated to pumped storage system using Salp Swarm Algorithm (SSA). This approach allows the examination of various energy sources and their combination to handle the optimal configuration of the hybrid system. The simulation and optimization process of the studied system have been carried out by MATLAB programming. The impact of the system under study on the grid is examined according to the power exchange values between the system and the grid. Moreover, different scenarios have been introduced for optimal operation. The simulation results indicate that these hybrid systems can reduce power exchange with the grid and ensure that the proposed system is economically and environmentally feasible. Furthermore, the results indicate the technical feasibility of seawater hydroelectric power plants in increasing the capacity of the electric grid to allow for high penetration of RES. Finally, the results showed that the best minimum value of the objective function is 3.9113 and showed that CO2 emission can be reduced about 29.65% per year compared to the conventional power plants.
引用
收藏
页码:1521 / 1536
页数:16
相关论文
共 50 条
  • [31] Optimal sizing of renewable energy storage: A techno-economic analysis of hydrogen, battery and hybrid systems considering degradation and seasonal storage
    Le, Tay Son
    Nguyen, Tuan Ngoc
    Bui, Dac-Khuong
    Ngo, Tuan Duc
    APPLIED ENERGY, 2023, 336
  • [32] Efficient Hybrid Renewable Energy System for Industrial Sector with On-Grid Time Management
    Hasan, Md. Mehedi
    Tanvir, Aman Abdulla
    Siddiquee, S. M. Shahnewaz
    Zubair, Ahmed
    2015 3RD INTERNATIONAL CONFERENCE ON GREEN ENERGY AND TECHNOLOGY (ICGET), 2015,
  • [33] Optimal On-Grid Hybrid Renewable Energy Model for Coastal Area : Bangladesh Perspective
    Hossain, Md Asad
    Kabir, Md Faisal
    Kabir, Rashad
    Islam, Md Rafiqul
    2014 2ND INTERNATIONAL CONFERENCE ON GREEN ENERGY AND TECHNOLOGY (ICGET), 2014, : 99 - 103
  • [34] Sizing of Energy Storage Systems for Grid Inertial Response
    Bera, Atri
    Abdelmalak, Michael
    Alzahrani, Saad
    Benidris, Mohammed
    Mitra, Joydeep
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [35] A state-of-the-art review and bibliometric analysis on the sizing optimization of off-grid hybrid renewable energy systems
    He, Yi
    Guo, Su
    Dong, Peixin
    Zhang, Yi
    Huang, Jing
    Zhou, Jianxu
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2023, 183
  • [36] Optimal sizing of grid-tied hybrid renewable energy systems considering inverter to PV ratio-A case study
    Nurunnabi, Md.
    Roy, Naruttam Kumar
    Pota, Hemanshu Roy
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2019, 11 (01)
  • [37] Sizing, optimization, control and energy management of hybrid renewable energy system—A review
    Ammari C.
    Belatrache D.
    Touhami B.
    Makhloufi S.
    Energy and Built Environment, 2022, 3 (04): : 399 - 411
  • [38] Green hydrogen based off-grid and on-grid hybrid energy systems
    Ceylan, Ceren
    Devrim, Yilser
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2023, 48 (99) : 39084 - 39096
  • [39] Robust energy management for an on-grid hybrid hydrogen refueling and battery swapping station based on renewable energy
    Xu, Xiao
    Hu, Weihao
    Liu, Wen
    Du, Yuefang
    Huang, Qi
    Chen, Zhe
    JOURNAL OF CLEANER PRODUCTION, 2022, 331
  • [40] DUAL ENERGY STORAGE FOR HYBRID ENERGY SYSTEMS WITH RENEWABLE ENERGY SOURCES
    Obukhov, Sergey G.
    Plotnikov, Igor A.
    Ibrahim, Ahmed
    Masolov, Vladimir G.
    BULLETIN OF THE TOMSK POLYTECHNIC UNIVERSITY-GEO ASSETS ENGINEERING, 2020, 331 (01): : 64 - 76