Tetracarboxylic acid cobalt phthalocyanine SAM on gold:: Potential applications as amperometric sensor for H2O2 and fabrication of glucose biosensor

被引:101
|
作者
Mashazi, Philani N.
Ozoemena, Kenneth I.
Nyokong, Tebello
机构
[1] Rhodes Univ, Dept Chem, ZA-6140 Grahamstown, South Africa
[2] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
基金
新加坡国家研究基金会;
关键词
cobalt phthalocyanine; glucose oxidase; self-assembled monolayer; hydrogen peroxide; glucose; impedance spectroscopy;
D O I
10.1016/j.electacta.2006.04.056
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This report describes the applications of cobalt tetracarboxylic acid phthalocyanine (CoTCAPc) self-assembled monolayer (SAM) immobilized onto a preformed 2-mercaptoethanol (Au-ME) SAM on gold surface (Au-ME-CoTCAPc SAM) as a potential amperometric sensor for the detection of hydrogen peroxide (H,02) at neutral pH conditions. The Au-ME-CoTCAPc SAM sensor showed a very fast amperometric response time of approximately 1 s, good linearity at the studied concentration range of up to 5 mu M with a coefficient R-2 = 0.993 and a detection limit of 0.4 mu M oxidatively. Also reductively, the sensor exhibited a very fast amperometric response time (similar to 1 s), linearity up to 5 mu M with a coefficient R-2 = 0.986 and a detection limit of 0.2 mu M. The cobalt tetracarboxylic acid phthalocyamne self-assembled monolayer was then evaluated as a mediator for glucose oxidase (GOx)-based biosensor. The GOx (enzyme) was immobilized covalently onto Au-ME-CoTCAN SAM using coupling agents: N-ethyl-N(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS), and the results demonstrated a good catalytic behavior. Kinetic parameters associated with the enzymatic and mediator reactions were estimated using electrochemical versions of Lineweaver-Burk and Hanes equation, and the stability of the sensor was tested. The biosensor (Au-ME-CoTCAPc-GOx SAM) electrode showed good sensitivity (7.5 nA/mM) with a good detection limit of 8.4 mu M at 3 sigma, smaller Michaelis-Menten constant (4.8 mM from Hanes plot) and very fast response time of approximately 5 s. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 50 条
  • [31] Amperometric H2O2 senor based on gold nanoparticles/poly (celestine blue) nanohybrid film
    Sangeetha, N. S.
    Narayanan, S. Sriman
    SN APPLIED SCIENCES, 2019, 1 (07):
  • [32] Detection of Nanomolar Concentrations H2O2 Using Cobalt (II) Phthalocyanine Modified GCE with MWCNTs
    Mounesh
    Reddy, K. R. Venugopala
    ANALYTICAL CHEMISTRY LETTERS, 2020, 10 (01) : 33 - 48
  • [33] Non-enzymatic SnO2-nanowire/GCE amperometric sensor for H2O2 sensing
    Zou, Guihua
    Sun, Liping
    Huo, Lihua
    Zhao, Hui
    MICROCHEMICAL JOURNAL, 2024, 203
  • [34] A disposable non-enzymatic dual sensor for simultaneous amperometric determination of NADH and H2O2
    Onat, Eda Kiymaz
    Kamac, Melike Bilgi
    Yilmaz, Merve
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2023, 53 (11) : 2213 - 2227
  • [35] Cobalt ferrite nanoparticles decorated on exfoliated graphene oxide, application for amperometric determination of NADH and H2O2
    Ensafi, Ali A.
    Alinajafi, Hossein A.
    Jafari-Asl, M.
    Rezaei, B.
    Ghazaei, F.
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 60 : 276 - 284
  • [36] Unzipped catalytic activity of copper in realizing bimetallic Ag@Cu nanowires as a better amperometric H2O2 sensor
    Easow, Jeena Susan
    Selvaraju, T.
    ELECTROCHIMICA ACTA, 2013, 112 : 648 - 654
  • [37] Preparation of poly(diallyldimethylammonium chloride)-functionalized graphene and its applications for H2O2 and glucose sensing
    Jia, Liping
    Liu, Jifeng
    Wang, Huaisheng
    ELECTROCHIMICA ACTA, 2013, 111 : 411 - 418
  • [38] Amperometric biosensor based on reductive H2O2 detection using pentacyanoferrate-bound polymer for creatinine determination
    Nieh, Chi-Hua
    Tsujimura, Seiya
    Shirai, Osamu
    Kano, Kenji
    ANALYTICA CHIMICA ACTA, 2013, 767 : 128 - 133
  • [39] A novel nonenzymatic H2O2 sensor based on cobalt hexacyanoferrate nanoparticles and graphene composite modified electrode
    Yang, Suling
    Li, Gang
    Wang, Guifang
    Zhao, Junhong
    Hu, Meifang
    Qu, Lingbo
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 208 : 593 - 599
  • [40] A new amperometric H2O2 biosensor based on nanocomposite films of chitosan-MWNTs, hemoglobin, and silver nanoparticles
    Li, Yancai
    Li, Yuanjun
    Yang, Yiyun
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (03) : 1133 - 1140