Tetracarboxylic acid cobalt phthalocyanine SAM on gold:: Potential applications as amperometric sensor for H2O2 and fabrication of glucose biosensor

被引:101
|
作者
Mashazi, Philani N.
Ozoemena, Kenneth I.
Nyokong, Tebello
机构
[1] Rhodes Univ, Dept Chem, ZA-6140 Grahamstown, South Africa
[2] Univ Pretoria, Dept Chem, ZA-0002 Pretoria, South Africa
基金
新加坡国家研究基金会;
关键词
cobalt phthalocyanine; glucose oxidase; self-assembled monolayer; hydrogen peroxide; glucose; impedance spectroscopy;
D O I
10.1016/j.electacta.2006.04.056
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
This report describes the applications of cobalt tetracarboxylic acid phthalocyanine (CoTCAPc) self-assembled monolayer (SAM) immobilized onto a preformed 2-mercaptoethanol (Au-ME) SAM on gold surface (Au-ME-CoTCAPc SAM) as a potential amperometric sensor for the detection of hydrogen peroxide (H,02) at neutral pH conditions. The Au-ME-CoTCAPc SAM sensor showed a very fast amperometric response time of approximately 1 s, good linearity at the studied concentration range of up to 5 mu M with a coefficient R-2 = 0.993 and a detection limit of 0.4 mu M oxidatively. Also reductively, the sensor exhibited a very fast amperometric response time (similar to 1 s), linearity up to 5 mu M with a coefficient R-2 = 0.986 and a detection limit of 0.2 mu M. The cobalt tetracarboxylic acid phthalocyamne self-assembled monolayer was then evaluated as a mediator for glucose oxidase (GOx)-based biosensor. The GOx (enzyme) was immobilized covalently onto Au-ME-CoTCAN SAM using coupling agents: N-ethyl-N(3-dimethylaminopropyl) carbodiimide (EDC) and N-hydroxy succinimide (NHS), and the results demonstrated a good catalytic behavior. Kinetic parameters associated with the enzymatic and mediator reactions were estimated using electrochemical versions of Lineweaver-Burk and Hanes equation, and the stability of the sensor was tested. The biosensor (Au-ME-CoTCAPc-GOx SAM) electrode showed good sensitivity (7.5 nA/mM) with a good detection limit of 8.4 mu M at 3 sigma, smaller Michaelis-Menten constant (4.8 mM from Hanes plot) and very fast response time of approximately 5 s. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 50 条
  • [1] Cobalt nitride nanowire array as an efficient electrochemical sensor for glucose and H2O2 detection
    Xie, Fengyu
    Cao, Xiaoqin
    Qu, Fengli
    Asiri, Abdullah M.
    Sun, Xuping
    SENSORS AND ACTUATORS B-CHEMICAL, 2018, 255 : 1254 - 1261
  • [2] Electropolymerized film of cobalt tetrabenzimidazolephthalocyanine for the amperometric detection of H2O2
    Mohammed, Imadadulla
    Nemakal, Manjunatha
    Sajjan, Veeresh A.
    Puttappashetty, Dayananda B.
    Sannegowda, Lokesh Koodlur
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 826 : 96 - 103
  • [3] Amperometric H2O2 sensor based on gold nanoparticles/poly (celestine blue) nanohybrid film
    N. S. Sangeetha
    S. Sriman Narayanan
    SN Applied Sciences, 2019, 1
  • [4] Fabrication and application of a diamond-film glucose biosensor based on a H2O2 microarray electrode
    Wu, JL
    Zhu, JZ
    Zhang, GX
    Lin, XR
    Cheng, NY
    ANALYTICA CHIMICA ACTA, 1996, 327 (02) : 133 - 137
  • [5] Fabrication of a sensitive amperometric sensor for NADH and H2O2 using palladium nanoparticles-multiwalled carbon nanotube nanohybrid
    Hamidi, Hassan
    Haghighi, Behzad
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 62 : 423 - 428
  • [6] Minimization of Interferences in Flow Injection Amperometric Glucose Biosensor Based on Oxidation of Enzymatically-produced H2O2
    Karakaya, Serkan
    Dilgin, Yusuf
    ELECTROANALYSIS, 2019, 31 (07) : 1373 - 1380
  • [7] Gold nanoparticles mediate the assembly of manganese dioxide nanoparticles for H2O2 amperometric sensing
    Li, Yali
    Zhang, Jia
    Zhu, Hui
    Yang, Fan
    Yang, Xiurong
    ELECTROCHIMICA ACTA, 2010, 55 (18) : 5123 - 5128
  • [8] Polyoxometalates as peroxidase mimetics and their applications in H2O2 and glucose detection
    Wang, Jingjing
    Han, Dongxue
    Wang, Xiaohong
    Qi, Bin
    Zhao, Meisheng
    BIOSENSORS & BIOELECTRONICS, 2012, 36 (01) : 18 - 21
  • [9] Amperometric Uric Acid Biosensor with Improved Analytical Performances Based on Alkaline-Stable H2O2 Transducer
    Ivekovic, Damir
    Japec, Matea
    Solar, Matea
    Zivkovic, Natasa
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (04): : 3252 - 3264
  • [10] Balancing the Aggregation of Cobalt Phthalocyanine on Carbon Nanohorn for Efficient H2O2 electrosynthesis in Neutral Electrolyte
    Ding, Yiqi
    Xing, Zhuo
    Kuai, Chunguang
    Wang, Feng Ryan
    Guo, Yuzheng
    CHEMELECTROCHEM, 2025,