Bootstrap techniques for sensitivity analysis and model selection in building thermal performance analysis

被引:69
作者
Tian, Wei [1 ]
Song, Jitian [1 ]
Li, Zhanyong [1 ]
de Wilde, Pieter [2 ]
机构
[1] Tianjin Univ Sci & Technol, Coll Mech Engn, Tianjin 300222, Peoples R China
[2] Univ Plymouth, Sch Architecture Design & Environm, Plymouth PL4 8AA, Devon, England
关键词
Building thermal performance; Bootstrap method; Sensitivity analysis; Model selection; ENERGY PERFORMANCE; UNCERTAINTY ANALYSIS; SIMULATION; OPTIMIZATION; CONSUMPTION; PREDICTION; IDENTIFICATION; METHODOLOGY; EFFICIENCY; DESIGN;
D O I
10.1016/j.apenergy.2014.08.110
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In regression analysis, there are two main aims: interpretation and prediction, which can be also applied in building performance analysis. Interpretation is used to understand the relationship between input parameters and building energy performance (also called sensitivity analysis), whereas prediction is used to create a reliable energy model to estimate building energy consumption. This article explores the implementation of a distribution-free bootstrap method for these two purposes. The bootstrap is a resampling method that enables assessment of the accuracy of an estimator by random sampling with replacement from an original dataset. An office building is used as a case study to demonstrate the application of this method in assessing building thermal performance. The results indicate that the probabilistic sensitivity analysis incorporating the bootstrap approach provides valuable insights into the variations in sensitivity indicators, which are not available from typical deterministic sensitivity analysis. The single point values from deterministic methods may lead to misleading prioritization of energy saving measures because they do not provide the distributions of sensitivity indicators. Information on prediction errors obtained from the bootstrap method can facilitate the selection of an appropriate building energy metamodel to more accurately predict the energy consumption of buildings, compared with the traditional one-time data splitting method (also called holdout cross-validation method), which partitions the data into a training set and a test set. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:320 / 328
页数:9
相关论文
共 84 条
[1]   A review on simulation-based optimization methods applied to building performance analysis [J].
Anh-Tuan Nguyen ;
Reiter, Sigrid ;
Rigo, Philippe .
APPLIED ENERGY, 2014, 113 :1043-1058
[2]  
[Anonymous], 2013, TRANSITION SUSTAINAB
[3]  
[Anonymous], 2013, ASHRAE HDB FUND
[4]   Sensitivity measures, ANOVA-like techniques and the use of bootstrap [J].
Archer, GEB ;
Saltelli, A ;
Sobol, IM .
JOURNAL OF STATISTICAL COMPUTATION AND SIMULATION, 1997, 58 (02) :99-120
[5]   Analysis of the building energy balance to investigate the effect of thermal insulation in summer conditions [J].
Ballarini, Ilaria ;
Corrado, Vincenzo .
ENERGY AND BUILDINGS, 2012, 52 :168-180
[6]   Resampling Methods for Meta-Model Validation with Recommendations for Evolutionary Computation [J].
Bischl, B. ;
Mersmann, O. ;
Trautmann, H. ;
Weihs, C. .
EVOLUTIONARY COMPUTATION, 2012, 20 (02) :249-275
[7]  
BRE, 2012, NCM NAT CALC METH AC
[8]   Performance evaluation of passive cooling in office buildings based on uncertainty and sensitivity analysis [J].
Breesch, H. ;
Janssens, A. .
SOLAR ENERGY, 2010, 84 (08) :1453-1467
[9]   Building energy performance analysis by an in-house developed dynamic simulation code: An investigation for different case studies [J].
Buonomano, Annamaria ;
Palombo, Adolfo .
APPLIED ENERGY, 2014, 113 :788-807
[10]  
Canty A., 2012, BOOT BOOTSTRAP R S P