Early experience with the AcrySof toric IOL for the correction of astigmatism in cataract surgery

被引:38
作者
Dardzhikova, Albena [1 ]
Shah, Chirag R. [1 ]
Gimbel, Howard V. [1 ,2 ]
机构
[1] Gimbel Eye Ctr, Calgary, AB T3A 2N1, Canada
[2] Loma Linda Univ, Loma Linda, CA 92350 USA
来源
CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE | 2009年 / 44卷 / 03期
关键词
cataract surgery; astigmatism; toric IOL; INTRAOCULAR-LENS IMPLANTATION; ROTATIONAL STABILITY; EYES;
D O I
10.3129/i09-048
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Objective: The AcrySof toric IOL (tIOL) became available in Canada in 2006, thereby giving surgeons another option in the correction of astigmatism during cataract surgery.The purpose of this paper is to report the early experience of the acrylic AcrySof tIOL. Design: Observational clinical study. Participants: One hundred eleven eyes, including 41 bilateral patients. Methods: Patients were implanted with the AcrySoftIOL by I surgeon between April and September 2007. The eyes were followed for 6 months and pre- and postrefractive outcomes were summarized. Results: Preoperatively, the mean refractive cylinder was -1.25 D compared with -0.32 D postoperative. At 6 months, 95.5% of eyes remained within 10 degrees of planned axis. Two eyes of I patient (1.8%) required bilateral repositioning at 2 weeks postoperative for significant rotation off axis. Conclusions: Based on our early postoperative experience, we have found the AcrySof tIOL to be successful in reducing moderate levels of astigmatism.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 11 条
[1]  
Auffarth G, 2007, OPHTHALMOLOGE, V104, P1024, DOI 10.1007/s00347-007-1659-x
[2]   Early rotational stability of the longer Staar toric intraocular lens - Fifty consecutive cases [J].
Chang, DF .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2003, 29 (05) :935-940
[3]   Meridional analysis for calculating the expected spherocylindrical refraction in eyes with toric intraocular lenses [J].
Fam, Han Bor ;
Lim, Kooi Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) :2072-2076
[4]   Combined toric intraocular lens implantation and relaxing incisions to reduce high preexisting astigmatism [J].
Gills, JP ;
Van Der Karr, M ;
Cherchio, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (09) :1585-1588
[5]   Expected effects of surgically induced astigmatism on AcrySof toric intraocular lens results [J].
Hill, Warren .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (03) :364-367
[6]   Adhesion of soluble fibronectin, laminin, and collagen type IV to intraocular lens materials [J].
Linnola, RJ ;
Sund, M ;
Ylönen, R ;
Pihlajaniemi, T .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (11) :1486-1491
[7]   Foldable toric intraocular lens for astigmatism correction in cataract patients [J].
Mendicute, Javier ;
Irigoyen, Cristina ;
Aramberri, Jaime ;
Ondarra, Ana ;
Montes-Mico, Robert .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2008, 34 (04) :601-607
[8]   Postoperative intraocular lens rotation -: A randomized comparison of plate and loop haptic implants [J].
Patel, CK ;
Ormonde, S ;
Rosen, PH ;
Bron, AJ .
OPHTHALMOLOGY, 1999, 106 (11) :2190-2195
[9]   Toric intraocular lenses for correcting astigmatism in 130 eyes [J].
Sun, XY ;
Vicary, D ;
Montgomery, P ;
Griffiths, M .
OPHTHALMOLOGY, 2000, 107 (09) :1776-1781
[10]   Toric intraocular lens implantation: 100 consecutive cases [J].
Till, JS ;
Yoder, PR ;
Wilcox, TK ;
Spielman, JL .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (02) :295-301