LQR Control of Wind Excited Benchmark Building Using Variable Stiffness Tuned Mass Damper

被引:13
作者
Deshmukh, S. N. [1 ]
Chandiramani, N. K. [1 ]
机构
[1] Indian Inst Technol, Dept Civil Engn, Bombay 400076, Maharashtra, India
关键词
SEMIACTIVE CONTROL; RESPONSE CONTROL; PROTECTION; ALGORITHM;
D O I
10.1155/2014/156523
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
LQR control of wind induced motion of a benchmark building is considered. The building is fitted with a semiactive variable stiffness tuned mass damper adapted from the literature. The nominal stiffness of the device corresponds to the fundamental frequency of the building and is included in the system matrix. This results in a linear time-invariant system, for which the desired control force is computed using LQR control. The control force thus computed is then realized by varying the device stiffness around its nominal value by using a simple control law. A nonlinear static analysis is performed in order to establish the range of linearity, in terms of the device (configuration) angle, for which the control law is valid. Results are obtained for the cases of zero and nonzero structural stiffness variation. The performance criteria evaluated show that the present method provides displacement control that is comparable with that of two existing controllers. The acceleration control, while not as good as that obtained with the existing active controller, is comparable or better than that obtained with the existing semiactive controller. By using substantially less power as well as control force, the present control yields comparable displacement control and reasonable acceleration control.
引用
收藏
页数:12
相关论文
共 21 条
[1]  
[Anonymous], [No title captured]
[2]   Bang-bang and semiactive control with variable stiffness TM ds [J].
Collins, Ruth ;
Basu, Biswajit ;
Broderick, Brian M. .
JOURNAL OF STRUCTURAL ENGINEERING, 2008, 134 (02) :310-317
[3]   A METHOD FOR SIMPLIFYING LINEAR DYNAMIC SYSTEMS [J].
DAVISON, EJ .
IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1966, AC11 (01) :93-+
[4]   Semi-active friction damping of large space truss structures [J].
Gaul, L ;
Albrecht, H ;
Wirnitzer, J .
SHOCK AND VIBRATION, 2004, 11 (3-4) :173-186
[5]   Structural control: Past, present, and future [J].
Housner, GW ;
Bergman, LA ;
Caughey, TK ;
Chassiakos, AG ;
Claus, RO ;
Masri, SF ;
Skelton, RE ;
Soong, TT ;
Spencer, BF ;
Yao, JTP .
JOURNAL OF ENGINEERING MECHANICS, 1997, 123 (09) :897-971
[6]   Semi-active control of structures using neuro-predictive algorithm for MR dampers [J].
K-Karamodin, A. ;
H-Kazemi, H. .
STRUCTURAL CONTROL & HEALTH MONITORING, 2010, 17 (03) :237-253
[7]   SEISMIC RESPONSE CONTROLLED STRUCTURE WITH ACTIVE VARIABLE STIFFNESS SYSTEM [J].
KOBORI, T ;
TAKAHASHI, M ;
NASU, T ;
NIWA, N ;
OGASAWARA, K .
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 1993, 22 (11) :925-941
[8]   Short time Fourier transform algorithm for wind response control of buildings with variable stiffness TMD [J].
Nagarajaiah, S ;
Varadarajan, N .
ENGINEERING STRUCTURES, 2005, 27 (03) :431-441
[9]   Structures with semiactive variable stiffness single/multiple tuned mass dampers [J].
Nagarajaiah, Satish ;
Sonmez, Ertan .
JOURNAL OF STRUCTURAL ENGINEERING, 2007, 133 (01) :67-77
[10]  
Naidu DesineniS., 2003, OPTIMAL CONTROL SYST