Predictors and Prognosis of Stent Fracture After Sirolimus-Eluting Stent Implantation

被引:51
作者
Ino, Yasushi [2 ]
Toyoda, Yasuaki [2 ]
Tanaka, Atsushi [1 ]
Ishii, Shuuta [2 ]
Kusuyama, Yoshio [2 ]
Kubo, Takashi [1 ]
Takarada, Shigeho [1 ]
Kitabata, Hironori [1 ]
Tanimoto, Takashi [1 ]
Mizukoshi, Masato [1 ]
Imanishi, Toshio [1 ]
Akasaka, Takashi [1 ]
机构
[1] Wakayama Med Univ, Dept Cardiovasc Med, Wakayama 6418510, Japan
[2] Wakayama Natl Hosp, Div Cardiol, Wakayama, Japan
关键词
Prognosis; Restenosis; Sirolimus-eluting stent; Stent fracture; CORONARY RESTENOSIS; FREQUENCY; STENOSIS;
D O I
10.1253/circj.CJ-09-0343
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Stent fracture is a cause of in-stent restenosis (ISR) after sirolimus-eluting stent (SES) implantation, so this study investigated the incidence. predictors and prognosis of stent fracture. Methods and Results: The 273 consecutive patients (364 lesions) after SES implantation and who had 6-9 month scheduled follow-up Coronary angiography (CAG) were divided into groups with and without stent fracture. Delta angle was defined as the difference in the angle in the target lesion between diastole and systole before the procedure. The incidence of stent fracture was 4.9% (18 of 364 lesions). Delta angle in the target lesion was larger in the fracture group (28.3 +/- 11.5 degrees vs 12.3 +/- 9.0 degrees, P<0.0001). Independent predictors of stent fracture were Delta angle and total stent length. The rates of binary restenosis and target lesion revascularization (TLR) were higher in the Fracture group (33% vs 4.0%. P=0.0002 and 28% vs 3.5%, P=0.0007, respectively). There were no major adverse cardiac events (MACE) in the fracture group during a mean 24-month follow-up after follow-up CAG. Conclusions: Predictors of stent fracture were Delta angle and total stent length. Although stent fracture was associated with ISR and TLR, it was not associated with MACE during long-term follow-up. (Circ J 2009: 73: 2036-2041)
引用
收藏
页码:2036 / 2041
页数:6
相关论文
共 27 条
[1]   Incidence and clinical impact of coronary stent fracture after sirolimus-eluting stent implantation [J].
Aoki, Jiro ;
Nakazawa, Gaku ;
Tanabe, Kengo ;
Hoye, Angela ;
Yamamoto, Hirosada ;
Nakayama, Tomohiro ;
Onuma, Yoshinobu ;
Higashikuni, Yasutomi ;
Otsuki, Syuji ;
Yagishita, Atsuhiko ;
Yachi, Sen ;
Nakajima, Hiroyoshi ;
Hara, Kazuhiro .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2007, 69 (03) :380-386
[2]   Long-term effects of polymer-based, slow-release, sirolimus-eluting stents in a porcine coronary model [J].
Carter, AJ ;
Aggarwal, M ;
Kopia, GA ;
Tio, F ;
Tsao, PS ;
Kolata, R ;
Yeung, AC ;
Llanos, G ;
Dooley, L ;
Falotico, R .
CARDIOVASCULAR RESEARCH, 2004, 63 (04) :617-624
[3]   Preliminary observations regarding angiographic pattern of restenosis after rapamycin-eluting stent implantation [J].
Colombo, A ;
Orlic, D ;
Stankovic, G ;
Corvaja, N ;
Spanos, V ;
Montorfano, M ;
Liistro, F ;
Carlino, M ;
Airoldi, F ;
Chieffo, A ;
Di Mario, C .
CIRCULATION, 2003, 107 (17) :2178-2180
[4]   Late restenosis following Sirolimus-eluting stent implantation [J].
Cosgrave, John ;
Corbett, Simon J. ;
Melzi, Gloria ;
Babic, Rade ;
Biondi-Zoccai, Giuseppe G. L. ;
Airoldi, Flavio ;
Chieffo, Alaide ;
Sangiorgi, Giuseppe M. ;
Montorfano, Matteo ;
Michev, Iassen ;
Carlino, Mauro ;
Colombo, Antonio .
AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (01) :41-44
[5]  
COWLEY MJ, 2006, J INTERV CARDIOL, V19, pS47
[6]   Clinical end points in coronary stent trials - A case for standardized definitions [J].
Cutlip, Donald E. ;
Windecker, Stephan ;
Mehran, Roxana ;
Boam, Ashley ;
Cohen, David J. ;
van Es, Gerrit-Anne ;
Steg, P. Gabriel ;
Morel, Marie-angele ;
Mauri, Laura ;
Vranckx, Pascal ;
McFadden, Eugene ;
Lansky, Alexandra ;
Hamon, Martial ;
Krucoff, Mitchell W. ;
Serruys, Patrick W. .
CIRCULATION, 2007, 115 (17) :2344-2351
[7]   Maintenance of long-term clinical benefit with sirolimus-eluting coronary stents -: Three-year results of the RAVEL trial [J].
Fajadet, J ;
Morice, MC ;
Bode, C ;
Barragan, P ;
Serruys, PW ;
Wijns, W ;
Constantini, CR ;
Guermonprez, JL ;
Eltchaninoff, H ;
Blanchard, D ;
Bartorelli, A ;
Laarman, GJ ;
Perin, MA ;
Sousa, JE ;
Schuler, G ;
Molnar, F ;
Guagliumi, G ;
Colombo, A ;
Hayashi, EB ;
Wülfert, E .
CIRCULATION, 2005, 111 (08) :1040-1044
[8]   Late incomplete lesion coverage following Cypher stent deployment for diffuse right coronary artery stenosis [J].
Halkin, A ;
Carlier, S ;
Leon, MB .
HEART, 2004, 90 (08) :e45
[9]   Late target lesion revascularization after implantation of sirolimus-eluting stent [J].
Hong, Myeong-Ki ;
Mintz, Gary S. ;
Lee, Cheol Whan ;
Park, Duk-Woo ;
Lee, Seung-Whan ;
Kim, Young-Hak ;
Jung, In-Hyun ;
Kim, Sang-Hyun ;
Cheong, Sang-Sig ;
Kim, Jae-Joong ;
Park, Seong-Wook ;
Park, Seung-Jung .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2008, 71 (03) :299-303
[10]  
KOBAYASHI T, 2006, JPN J INTERV CARDIOL, V21, P351