Direct observation on supersonic microprojectile penetration of carbon fiber composites with ultrafast synchrotron X-ray phase contrast imaging

被引:9
|
作者
Bie, B. X. [1 ]
Chen, S. [2 ]
Sun, T. [3 ]
Fezzaa, K. [3 ]
Huang, J. Y. [2 ]
Luo, S. N. [1 ]
机构
[1] Southwest Jiaotong Univ, Key Lab Adv Technol Mat, Minist Educ, Chengdu 610031, Sichuan, Peoples R China
[2] Peac Inst Multiscale Sci, Chengdu 610027, Sichuan, Peoples R China
[3] Argonne Natl Lab, Adv Photon Source, Lemont, IL 60439 USA
基金
中国国家自然科学基金;
关键词
Carbon fiber reinforced epoxy composite; High-speed penetration; X-ray imaging; Impact damage; FE modeling; LOW-VELOCITY IMPACT; SPHERICAL CAVITY-EXPANSION; FINITE-ELEMENT-ANALYSIS; CONE PENETRATION; DAMAGE; BEHAVIOR; MODEL; DEFORMATION; PERFORMANCE; COMPRESSION;
D O I
10.1016/j.carbon.2020.10.058
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
High-speed penetration into carbon fiber composites is of fundamental importance to materials science and impact engineering, but research along this line suffers considerably from the lack of direct experimental observations. Here we investigate such penetration dynamics of a unidirectional carbon fiber reinforced epoxy (UCFRE) composite, with a combination of in situ, ultrafast, synchrotron phase contrast imaging and finite element (FE) analysis. The experiments yield the first direct observation on projectile trajectories and fiber-scale deformation and damage in the UCFRE composites during supersonic microprojectile penetration, for different fiber orientations (0 degrees - 90 degrees from the impact direction) and projectile velocities (600 - 850 m.s(-1)), at unprecedented temporal (similar to 100 ps) and spatial (5 mu m) resolutions. The maximum penetration depth decreases with increasing fiber orientation angles, as a result of anisotropic damage evolution in the composite sample. Strain localizations are prone to develop along a direction perpendicular to the fiber orientation, while the damage or cavity region, along the fiber direction. FE modeling with a three-dimensional Hashin criterion yields consistent projectile trajectory and cavity morphology with the experimental results. With increasing fiber orientation angles, damage analyses show a transition in the damage mode from fiber compression to matrix compression damage, in line with the increasing maximum penetration depth. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页码:781 / 790
页数:10
相关论文
共 50 条
  • [21] Principles of Different X-ray Phase-Contrast Imaging: A Review
    Tao, Siwei
    He, Congxiao
    Hao, Xiang
    Kuang, Cuifang
    Liu, Xu
    APPLIED SCIENCES-BASEL, 2021, 11 (07):
  • [22] Hard x-ray phase contrast imaging of black lipid membranes
    Beerlink, A.
    Mell, M.
    Tolkiehn, M.
    Salditt, T.
    APPLIED PHYSICS LETTERS, 2009, 95 (20)
  • [23] A comparison of absorption and phase contrast for X-ray imaging of biological cells
    Nave, Colin
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1490 - 1504
  • [24] Sensitivity of edge illumination X-ray phase-contrast imaging
    Diemoz, P. C.
    Endrizzi, M.
    Bravin, A.
    Robinson, I. K.
    Olivo, A.
    PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY A-MATHEMATICAL PHYSICAL AND ENGINEERING SCIENCES, 2014, 372 (2010):
  • [25] Fast X-ray digital imager for high-speed phase-contrast X-ray imaging
    Yoneyama, Akio
    Takeda, Tohoru
    Wu, Jin
    Lwin, Thet-Thet
    Hyodo, Kazuyuki
    Hirai, Yasuharu
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2007, 46 (3A): : 1205 - 1207
  • [26] Image Fusion in X-Ray Differential Phase-Contrast Imaging
    Haas, W.
    Polyanskaya, M.
    Bayer, F.
    Goedel, K.
    Hofmann, H.
    Rieger, J.
    Ritter, A.
    Weber, T.
    Wucherer, L.
    Durst, J.
    Michel, T.
    Anton, G.
    Hornegger, J.
    MEDICAL IMAGING 2012: IMAGE PROCESSING, 2012, 8314
  • [27] Wide-area phase-contrast X-ray imaging using large X-ray interferometers
    Momose, A
    Takeda, T
    Yoneyama, A
    Koyama, I
    Itai, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 917 - 920
  • [28] Two-stage wicking of yarns at the fiber scale investigated by synchrotron X-ray phase-contrast fast tomography
    Parada, Marcelo Yoiti Ito
    Schleputz, Christian Matthias
    Rossi, Rene Michel
    Derome, Dominique
    Carmeliet, Jan
    TEXTILE RESEARCH JOURNAL, 2019, 89 (23-24) : 4967 - 4979
  • [29] Nanoscale in situ observation of damage formation in carbon fiber/epoxy composites under mixed-mode loading using synchrotron radiation X-ray computed tomography
    Kimura, Masao
    Watanabe, Toshiki
    Oshima, Sota
    Takeichi, Yasuo
    Niwa, Yasuhiro
    Seryo, Yuji
    Hojo, Masaki
    COMPOSITES SCIENCE AND TECHNOLOGY, 2022, 230
  • [30] In situ observation of crystal reorientation in polygranular graphite by synchrotron X-ray diffraction and neutron imaging
    Zillhardt, Thomas
    Burca, Genoveva
    Ludwig, Wolfgang
    Liu, Dong
    Marrow, T. James
    CARBON, 2023, 214